Performance Evaluation of Heat Exchangers in a Polyethylene Plant
This paper evaluates the performance of three heat exchanger units (2-E-2301, 3-E-901 and 3-E-401) in a polyethylene plant. Steady state monitoring and direct collection of data from the equipment in the plant were performed and the data were analyzed by using energy equations to determine the ove...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Taiwan Association of Engineering and Technology Innovation
2013-01-01
|
Series: | International Journal of Engineering and Technology Innovation |
Subjects: | |
Online Access: | http://sparc.nfu.edu.tw/~ijeti/download/V3-no1-49-57.pdf |
Summary: | This paper evaluates the performance of three heat exchanger units (2-E-2301, 3-E-901 and 3-E-401) in a
polyethylene plant. Steady state monitoring and direct collection of data from the equipment in the plant were
performed and the data were analyzed by using energy equations to determine the overall heat transfer coefficient,
heat duty, temperature and pressure range of hot and cold fluids, capacity ratio and effectiveness. The results show
that for 2-E-2301, the overall heat transfer coefficient is over 50 percent less than the design figure and the heat duty
is over 75 percent than the design figure. For the 3-E-901 the heat duty and the overall heat transfer are over 75
percent less than the design figure which was traceable to fouling. This affected the effectiveness, capacity ratio and
temperature range of the hot and cold fluid. For the 3-E-401, the heat duty was found to be within the limit of design
figure. The temperature difference in the hot fluid side and the capacity ratio were within the limits of the design
figure. Thus, the results show qualitative performance evaluation of the heat exchangers. |
---|---|
ISSN: | 2223-5329 2226-809X |