Using a reconstruction locking compression plate as external fixator in infected open clavicle fracture

Open clavicle fracture is an uncommon injury mostly caused by severe direct trauma. It is often associated with multiple organ injuries. Generally, surgical intervention with debridement and fracture repair is always indicated in order to prevent infection, non-union, and malalignment. In situations...

Full description

Bibliographic Details
Main Authors: Norachart Sirisreetreerux, Paphon Sa-ngasoongsong, Pongsthorn Chanplakorn, Noratep Kulachote, Sukij Laohajaroensombat, Chanyut Suphachatwong, Vajara Phiphobmongkol, Wiwat Wajanavisit
Format: Article
Language:English
Published: Open Medical Publishing 2013-06-01
Series:Orthopedic Reviews
Subjects:
Online Access:http://www.pagepress.org/journals/index.php/or/article/view/4583
id doaj-d899c3209ac54ab1b435e3d0db5487f1
record_format Article
spelling doaj-d899c3209ac54ab1b435e3d0db5487f12021-05-02T17:54:50ZengOpen Medical PublishingOrthopedic Reviews2035-82372035-81642013-06-0152e11e1110.4081/or.2013.e112493Using a reconstruction locking compression plate as external fixator in infected open clavicle fractureNorachart Sirisreetreerux0Paphon Sa-ngasoongsong1Pongsthorn Chanplakorn2Noratep Kulachote3Sukij Laohajaroensombat4Chanyut Suphachatwong5Vajara Phiphobmongkol6Wiwat Wajanavisit7Faculty of Medicine, Ramathibodi Hospital, Mahidol UniversityFaculty of Medicine, Ramathibodi Hospital, Mahidol UniversityFaculty of Medicine, Ramathibodi Hospital, Mahidol UniversityFaculty of Medicine, Ramathibodi Hospital, Mahidol UniversityFaculty of Medicine, Ramathibodi Hospital, Mahidol UniversityFaculty of Medicine, Ramathibodi Hospital, Mahidol UniversityDepartment of Orthopaedic Surgery, Bhumibol Adulyadej Hospital, Royal Thai Air ForceFaculty of Medicine, Ramathibodi Hospital, Mahidol UniversityOpen clavicle fracture is an uncommon injury mostly caused by severe direct trauma. It is often associated with multiple organ injuries. Generally, surgical intervention with debridement and fracture repair is always indicated in order to prevent infection, non-union, and malalignment. In situations of bony exposure and significant contamination concomitant with severe soft tissue damage, the external fixation is the treatment of choice because of the possibility it offers of providing stable fixation with minimal local tissue damage resulting in excellent union rates and better soft tissue outcome. Nevertheless, traditional external fixation encountered some potential problems as its bulkiness and sharp edges caused discomfort to the patient. In this study, we present an interesting case of a polytraumatized patient with a gunshot injury with complex open clavicle fracture that was successfully treated with external fixation using reconstruction with a locking compression plate as definitive treatment.http://www.pagepress.org/journals/index.php/or/article/view/4583open clavicle fracture, LCP external fixation, damage control surgery
collection DOAJ
language English
format Article
sources DOAJ
author Norachart Sirisreetreerux
Paphon Sa-ngasoongsong
Pongsthorn Chanplakorn
Noratep Kulachote
Sukij Laohajaroensombat
Chanyut Suphachatwong
Vajara Phiphobmongkol
Wiwat Wajanavisit
spellingShingle Norachart Sirisreetreerux
Paphon Sa-ngasoongsong
Pongsthorn Chanplakorn
Noratep Kulachote
Sukij Laohajaroensombat
Chanyut Suphachatwong
Vajara Phiphobmongkol
Wiwat Wajanavisit
Using a reconstruction locking compression plate as external fixator in infected open clavicle fracture
Orthopedic Reviews
open clavicle fracture, LCP external fixation, damage control surgery
author_facet Norachart Sirisreetreerux
Paphon Sa-ngasoongsong
Pongsthorn Chanplakorn
Noratep Kulachote
Sukij Laohajaroensombat
Chanyut Suphachatwong
Vajara Phiphobmongkol
Wiwat Wajanavisit
author_sort Norachart Sirisreetreerux
title Using a reconstruction locking compression plate as external fixator in infected open clavicle fracture
title_short Using a reconstruction locking compression plate as external fixator in infected open clavicle fracture
title_full Using a reconstruction locking compression plate as external fixator in infected open clavicle fracture
title_fullStr Using a reconstruction locking compression plate as external fixator in infected open clavicle fracture
title_full_unstemmed Using a reconstruction locking compression plate as external fixator in infected open clavicle fracture
title_sort using a reconstruction locking compression plate as external fixator in infected open clavicle fracture
publisher Open Medical Publishing
series Orthopedic Reviews
issn 2035-8237
2035-8164
publishDate 2013-06-01
description Open clavicle fracture is an uncommon injury mostly caused by severe direct trauma. It is often associated with multiple organ injuries. Generally, surgical intervention with debridement and fracture repair is always indicated in order to prevent infection, non-union, and malalignment. In situations of bony exposure and significant contamination concomitant with severe soft tissue damage, the external fixation is the treatment of choice because of the possibility it offers of providing stable fixation with minimal local tissue damage resulting in excellent union rates and better soft tissue outcome. Nevertheless, traditional external fixation encountered some potential problems as its bulkiness and sharp edges caused discomfort to the patient. In this study, we present an interesting case of a polytraumatized patient with a gunshot injury with complex open clavicle fracture that was successfully treated with external fixation using reconstruction with a locking compression plate as definitive treatment.
topic open clavicle fracture, LCP external fixation, damage control surgery
url http://www.pagepress.org/journals/index.php/or/article/view/4583
work_keys_str_mv AT norachartsirisreetreerux usingareconstructionlockingcompressionplateasexternalfixatorininfectedopenclaviclefracture
AT paphonsangasoongsong usingareconstructionlockingcompressionplateasexternalfixatorininfectedopenclaviclefracture
AT pongsthornchanplakorn usingareconstructionlockingcompressionplateasexternalfixatorininfectedopenclaviclefracture
AT noratepkulachote usingareconstructionlockingcompressionplateasexternalfixatorininfectedopenclaviclefracture
AT sukijlaohajaroensombat usingareconstructionlockingcompressionplateasexternalfixatorininfectedopenclaviclefracture
AT chanyutsuphachatwong usingareconstructionlockingcompressionplateasexternalfixatorininfectedopenclaviclefracture
AT vajaraphiphobmongkol usingareconstructionlockingcompressionplateasexternalfixatorininfectedopenclaviclefracture
AT wiwatwajanavisit usingareconstructionlockingcompressionplateasexternalfixatorininfectedopenclaviclefracture
_version_ 1721489255106084864