Effectiveness Analysis and Temperature Effect Mechanism on Chemical and Electrical-Based Transformer Insulation Diagnostic Parameters Obtained from PDC Data

The dielectric monitoring/diagnostic tool, such as Polarization and Depolarization Current (PDC) measurement, is now being widely applied to obtain the status of deteriorated transformers around the world. Nowadays, several works have reported that the chemical and electrical-based transformer insul...

Full description

Bibliographic Details
Main Authors: Hanbo Zheng, Jiefeng Liu, Yiyi Zhang, Yijie Ma, Yang Shen, Xiaochen Zhen, Zilai Chen
Format: Article
Language:English
Published: MDPI AG 2018-01-01
Series:Energies
Subjects:
Online Access:http://www.mdpi.com/1996-1073/11/1/146
id doaj-d88b672fcb804047984de419afcd04e9
record_format Article
spelling doaj-d88b672fcb804047984de419afcd04e92020-11-25T01:11:49ZengMDPI AGEnergies1996-10732018-01-0111114610.3390/en11010146en11010146Effectiveness Analysis and Temperature Effect Mechanism on Chemical and Electrical-Based Transformer Insulation Diagnostic Parameters Obtained from PDC DataHanbo Zheng0Jiefeng Liu1Yiyi Zhang2Yijie Ma3Yang Shen4Xiaochen Zhen5Zilai Chen6Guangxi Key Laboratory of Power System Optimization and Energy Technology, Guangxi University, Nanning 530004, Guangxi, ChinaGuangxi Key Laboratory of Power System Optimization and Energy Technology, Guangxi University, Nanning 530004, Guangxi, ChinaGuangxi Key Laboratory of Power System Optimization and Energy Technology, Guangxi University, Nanning 530004, Guangxi, ChinaShijiazhuang Power Supply Branch of State Grid Electric Power Company, Shijiazhuang 050000, Hebei, ChinaShijiazhuang Power Supply Branch of State Grid Electric Power Company, Shijiazhuang 050000, Hebei, ChinaShijiazhuang Power Supply Branch of State Grid Electric Power Company, Shijiazhuang 050000, Hebei, ChinaShijiazhuang Power Supply Branch of State Grid Electric Power Company, Shijiazhuang 050000, Hebei, ChinaThe dielectric monitoring/diagnostic tool, such as Polarization and Depolarization Current (PDC) measurement, is now being widely applied to obtain the status of deteriorated transformers around the world. Nowadays, several works have reported that the chemical and electrical-based transformer insulation diagnostic parameters (absorption ratio, polarization index, paper conductivity, oil conductivity, insulation resistance, etc.) can be easily calculated from the PDC data. It is a fact that before using these parameters to obtain the status of deteriorated transformers, the power engineers should prudently investigate the effectiveness of these parameters. However, there are few papers that investigate the important issue. In addition, the understanding of temperature effect mechanism on these parameters should also be prudently studied. In the present work, we firstly prepare several oil-impregnated pressboard specimens with various insulation statuses by using a sequence of thermal ageing and moisture absorption experiments launched in the laboratory, and then the PDC measurement is performed to obtain the chemical and electrical-based transformer insulation diagnostic parameters. Finally, we systematically interpret the effectiveness and temperature effect mechanism on these chemical and electrical-based transformer insulation diagnostic parameters.http://www.mdpi.com/1996-1073/11/1/146dielectric monitoring/diagnostic toolpolarization and depolarization current (PDC)transformerchemical and electrical-based transformer insulation diagnostic parameterseffectivenesstemperature effect mechanism
collection DOAJ
language English
format Article
sources DOAJ
author Hanbo Zheng
Jiefeng Liu
Yiyi Zhang
Yijie Ma
Yang Shen
Xiaochen Zhen
Zilai Chen
spellingShingle Hanbo Zheng
Jiefeng Liu
Yiyi Zhang
Yijie Ma
Yang Shen
Xiaochen Zhen
Zilai Chen
Effectiveness Analysis and Temperature Effect Mechanism on Chemical and Electrical-Based Transformer Insulation Diagnostic Parameters Obtained from PDC Data
Energies
dielectric monitoring/diagnostic tool
polarization and depolarization current (PDC)
transformer
chemical and electrical-based transformer insulation diagnostic parameters
effectiveness
temperature effect mechanism
author_facet Hanbo Zheng
Jiefeng Liu
Yiyi Zhang
Yijie Ma
Yang Shen
Xiaochen Zhen
Zilai Chen
author_sort Hanbo Zheng
title Effectiveness Analysis and Temperature Effect Mechanism on Chemical and Electrical-Based Transformer Insulation Diagnostic Parameters Obtained from PDC Data
title_short Effectiveness Analysis and Temperature Effect Mechanism on Chemical and Electrical-Based Transformer Insulation Diagnostic Parameters Obtained from PDC Data
title_full Effectiveness Analysis and Temperature Effect Mechanism on Chemical and Electrical-Based Transformer Insulation Diagnostic Parameters Obtained from PDC Data
title_fullStr Effectiveness Analysis and Temperature Effect Mechanism on Chemical and Electrical-Based Transformer Insulation Diagnostic Parameters Obtained from PDC Data
title_full_unstemmed Effectiveness Analysis and Temperature Effect Mechanism on Chemical and Electrical-Based Transformer Insulation Diagnostic Parameters Obtained from PDC Data
title_sort effectiveness analysis and temperature effect mechanism on chemical and electrical-based transformer insulation diagnostic parameters obtained from pdc data
publisher MDPI AG
series Energies
issn 1996-1073
publishDate 2018-01-01
description The dielectric monitoring/diagnostic tool, such as Polarization and Depolarization Current (PDC) measurement, is now being widely applied to obtain the status of deteriorated transformers around the world. Nowadays, several works have reported that the chemical and electrical-based transformer insulation diagnostic parameters (absorption ratio, polarization index, paper conductivity, oil conductivity, insulation resistance, etc.) can be easily calculated from the PDC data. It is a fact that before using these parameters to obtain the status of deteriorated transformers, the power engineers should prudently investigate the effectiveness of these parameters. However, there are few papers that investigate the important issue. In addition, the understanding of temperature effect mechanism on these parameters should also be prudently studied. In the present work, we firstly prepare several oil-impregnated pressboard specimens with various insulation statuses by using a sequence of thermal ageing and moisture absorption experiments launched in the laboratory, and then the PDC measurement is performed to obtain the chemical and electrical-based transformer insulation diagnostic parameters. Finally, we systematically interpret the effectiveness and temperature effect mechanism on these chemical and electrical-based transformer insulation diagnostic parameters.
topic dielectric monitoring/diagnostic tool
polarization and depolarization current (PDC)
transformer
chemical and electrical-based transformer insulation diagnostic parameters
effectiveness
temperature effect mechanism
url http://www.mdpi.com/1996-1073/11/1/146
work_keys_str_mv AT hanbozheng effectivenessanalysisandtemperatureeffectmechanismonchemicalandelectricalbasedtransformerinsulationdiagnosticparametersobtainedfrompdcdata
AT jiefengliu effectivenessanalysisandtemperatureeffectmechanismonchemicalandelectricalbasedtransformerinsulationdiagnosticparametersobtainedfrompdcdata
AT yiyizhang effectivenessanalysisandtemperatureeffectmechanismonchemicalandelectricalbasedtransformerinsulationdiagnosticparametersobtainedfrompdcdata
AT yijiema effectivenessanalysisandtemperatureeffectmechanismonchemicalandelectricalbasedtransformerinsulationdiagnosticparametersobtainedfrompdcdata
AT yangshen effectivenessanalysisandtemperatureeffectmechanismonchemicalandelectricalbasedtransformerinsulationdiagnosticparametersobtainedfrompdcdata
AT xiaochenzhen effectivenessanalysisandtemperatureeffectmechanismonchemicalandelectricalbasedtransformerinsulationdiagnosticparametersobtainedfrompdcdata
AT zilaichen effectivenessanalysisandtemperatureeffectmechanismonchemicalandelectricalbasedtransformerinsulationdiagnosticparametersobtainedfrompdcdata
_version_ 1725169540279566336