Dose calculation in Abdominal-Pelvic CT examinations from two hospitals in the Lisbon area
This work aims to evaluate whether the dose values received by patients submitted to Abdominal-pelvic Computed Tomography (CT) in two hospitals in the Lisbon area do agree with the Diagnostic Reference Levels. The dosimetric units of examinations performed with modulated and continuous current in bo...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
ALIES - Associação Lusófona para o Desenvolvimento da Investigação e do Ensino das Ciências da Saúde
2012-06-01
|
Series: | Journal Biomedical and Biopharmaceutical Research (BBR) |
Subjects: | |
Online Access: | http://www.alies.pt/BBR%20Editions/Vol-9-1-2012/Article4_9n1.pdf |
id |
doaj-d8776379db4a458f8134a305b71ecd21 |
---|---|
record_format |
Article |
spelling |
doaj-d8776379db4a458f8134a305b71ecd212020-11-24T21:43:37ZengALIES - Associação Lusófona para o Desenvolvimento da Investigação e do Ensino das Ciências da SaúdeJournal Biomedical and Biopharmaceutical Research (BBR) 2182-23602182-23792012-06-0191556610.19277/bbr.9.1.27Dose calculation in Abdominal-Pelvic CT examinations from two hospitals in the Lisbon areaTânia Umbelino0Tatiana Silva1Frederico Teixeira2Luís Mendes3Piedade Falcão4Paulo Pereira5Nuno Matela6ERISA – Escola Superior de Saúde Ribeiro Sanches, Direcção de RadiologiaERISA – Escola Superior de Saúde Ribeiro Sanches, Direcção de RadiologiaERISA – Escola Superior de Saúde Ribeiro Sanches, Direcção de RadiologiaERISA – Escola Superior de Saúde Ribeiro Sanches, Direcção de RadiologiaCentro Hospitalar Lisboa Central, Hospital São JoséERISA – Escola Superior de Saúde Ribeiro Sanches, Direcção de RadiologiaERISA – Escola Superior de Saúde Ribeiro Sanches, Direcção de Radiologia; Instituto de Biofísica e Engenharia Biomédica, Faculdade de Ciências, Universidade de LisboaThis work aims to evaluate whether the dose values received by patients submitted to Abdominal-pelvic Computed Tomography (CT) in two hospitals in the Lisbon area do agree with the Diagnostic Reference Levels. The dosimetric units of examinations performed with modulated and continuous current in both hospitals were also compared. The study consisted in collecting data from 200 abdominal - pelvic CT's, obtained in two hospitals (100 per hospital). In Hospital A, the mean DLP was 562.34 mGy.cm and the average values CTDIvol was 12.06 mGy. In Hospital B, the mean DLPand CTDIvol was 767.14 mGy.cm and 15.02 mGy, respectively. We have concluded that, from this sample, none of the dosimetric units values exceeded the Diagnostic Reference Levels values. It was also noted that tests performed in B involved higher doses of patient exposure to ionizing radiation.http://www.alies.pt/BBR%20Editions/Vol-9-1-2012/Article4_9n1.pdfAbdomen-pelvic CTDosimetric unitsDiagnostic Reference Levelsmodulated currentcontinuous current |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Tânia Umbelino Tatiana Silva Frederico Teixeira Luís Mendes Piedade Falcão Paulo Pereira Nuno Matela |
spellingShingle |
Tânia Umbelino Tatiana Silva Frederico Teixeira Luís Mendes Piedade Falcão Paulo Pereira Nuno Matela Dose calculation in Abdominal-Pelvic CT examinations from two hospitals in the Lisbon area Journal Biomedical and Biopharmaceutical Research (BBR) Abdomen-pelvic CT Dosimetric units Diagnostic Reference Levels modulated current continuous current |
author_facet |
Tânia Umbelino Tatiana Silva Frederico Teixeira Luís Mendes Piedade Falcão Paulo Pereira Nuno Matela |
author_sort |
Tânia Umbelino |
title |
Dose calculation in Abdominal-Pelvic CT examinations from two hospitals in the Lisbon area |
title_short |
Dose calculation in Abdominal-Pelvic CT examinations from two hospitals in the Lisbon area |
title_full |
Dose calculation in Abdominal-Pelvic CT examinations from two hospitals in the Lisbon area |
title_fullStr |
Dose calculation in Abdominal-Pelvic CT examinations from two hospitals in the Lisbon area |
title_full_unstemmed |
Dose calculation in Abdominal-Pelvic CT examinations from two hospitals in the Lisbon area |
title_sort |
dose calculation in abdominal-pelvic ct examinations from two hospitals in the lisbon area |
publisher |
ALIES - Associação Lusófona para o Desenvolvimento da Investigação e do Ensino das Ciências da Saúde |
series |
Journal Biomedical and Biopharmaceutical Research (BBR) |
issn |
2182-2360 2182-2379 |
publishDate |
2012-06-01 |
description |
This work aims to evaluate whether the dose values received by patients submitted to Abdominal-pelvic Computed Tomography (CT) in two hospitals in the Lisbon area do agree with the Diagnostic Reference Levels. The dosimetric units of examinations performed with modulated and continuous current in both hospitals were also compared. The study consisted in collecting data from 200 abdominal - pelvic CT's, obtained in two hospitals (100 per hospital). In Hospital A, the mean DLP was 562.34 mGy.cm and the average values CTDIvol was 12.06 mGy. In Hospital B, the mean DLPand CTDIvol was 767.14 mGy.cm and 15.02 mGy, respectively. We have concluded that, from this sample, none of the dosimetric units values exceeded the Diagnostic Reference Levels values. It was also noted that tests performed in B involved higher doses of patient exposure to ionizing radiation. |
topic |
Abdomen-pelvic CT Dosimetric units Diagnostic Reference Levels modulated current continuous current |
url |
http://www.alies.pt/BBR%20Editions/Vol-9-1-2012/Article4_9n1.pdf |
work_keys_str_mv |
AT taniaumbelino dosecalculationinabdominalpelvicctexaminationsfromtwohospitalsinthelisbonarea AT tatianasilva dosecalculationinabdominalpelvicctexaminationsfromtwohospitalsinthelisbonarea AT fredericoteixeira dosecalculationinabdominalpelvicctexaminationsfromtwohospitalsinthelisbonarea AT luismendes dosecalculationinabdominalpelvicctexaminationsfromtwohospitalsinthelisbonarea AT piedadefalcao dosecalculationinabdominalpelvicctexaminationsfromtwohospitalsinthelisbonarea AT paulopereira dosecalculationinabdominalpelvicctexaminationsfromtwohospitalsinthelisbonarea AT nunomatela dosecalculationinabdominalpelvicctexaminationsfromtwohospitalsinthelisbonarea |
_version_ |
1725913102420017152 |