PENURUNAN KADAR AMONIA, NITRIT DAN NITRAT LIMBAH CAIR INDUSTRI TAHU DI DESA KALISARI, CILONGOK MENGGUNAKAN SISTEM ZEOLIT TERAKTIVASI DAN TERIMPREGNASI TiO2
Treatment of the tofu industry wastewater by activated zeolite system and TiO2 impregnated zeolite system was conducted. The systems are one of the alternatif method in decreasing ammonia, nitrite and nitrate contents in tofu industry wastewater. The research was aimed to decide the optimum loading...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Jenderal Soedirman University
2007-11-01
|
Series: | Molekul |
Subjects: | |
Online Access: | http://www.jmolekul.com/?download=2.2.44.pdf |
id |
doaj-d87572f28c4f40fc9f71d7b17d821fe1 |
---|---|
record_format |
Article |
spelling |
doaj-d87572f28c4f40fc9f71d7b17d821fe12020-11-25T00:56:30ZengJenderal Soedirman UniversityMolekul1907-97611907-97612007-11-01224452PENURUNAN KADAR AMONIA, NITRIT DAN NITRAT LIMBAH CAIR INDUSTRI TAHU DI DESA KALISARI, CILONGOK MENGGUNAKAN SISTEM ZEOLIT TERAKTIVASI DAN TERIMPREGNASI TiO2Irmanto0Suyata1Program Studi Kimia, Jurusan MIPA, Fakultas Sains dan Teknik, UNSOED, PurwokertoProgram Studi Kimia, Jurusan MIPA, Fakultas Sains dan Teknik, UNSOED, PurwokertoTreatment of the tofu industry wastewater by activated zeolite system and TiO2 impregnated zeolite system was conducted. The systems are one of the alternatif method in decreasing ammonia, nitrite and nitrate contents in tofu industry wastewater. The research was aimed to decide the optimum loading rate of the wastewater into zeolite system. The loading rate variety are: 160, 240, 320, 400 and 480 L m-2 day-1. Then also determined the efficiency of zeolite system to decrease ammonia, nitrite and nitrate contents in tofu industry wastewater by using the optimum loading rate. The result of the research showed that these three zeolite systems were able to decrease ammonia, nitrite and nitrate contents in tofu industry wastewater by optimum loading rate 320 L m-2 day-1. The efficiency of these three zeolite systems in decreasing the ammonia, nitrite and nitrate contents in tofu industry wastewater respectively were 74.96%, 70.36%, 65.57% for acid activated zeolite system, 84.26%, 72.36%, 76.36% for base activated zeolite system, and 75.50%, 70.35%, 71.71% for TiO2 impregnated zeolite system. From three of those zeolite systems, base activated zeolite system was the highest efficiency in decreasing the ammonia, nitrite and nitrate contents in tofu industry wastewater.http://www.jmolekul.com/?download=2.2.44.pdfZeolitetofu industryammonianitritenitrate. |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Irmanto Suyata |
spellingShingle |
Irmanto Suyata PENURUNAN KADAR AMONIA, NITRIT DAN NITRAT LIMBAH CAIR INDUSTRI TAHU DI DESA KALISARI, CILONGOK MENGGUNAKAN SISTEM ZEOLIT TERAKTIVASI DAN TERIMPREGNASI TiO2 Molekul Zeolite tofu industry ammonia nitrite nitrate. |
author_facet |
Irmanto Suyata |
author_sort |
Irmanto |
title |
PENURUNAN KADAR AMONIA, NITRIT DAN NITRAT LIMBAH CAIR INDUSTRI TAHU DI DESA KALISARI, CILONGOK MENGGUNAKAN SISTEM ZEOLIT TERAKTIVASI DAN TERIMPREGNASI TiO2 |
title_short |
PENURUNAN KADAR AMONIA, NITRIT DAN NITRAT LIMBAH CAIR INDUSTRI TAHU DI DESA KALISARI, CILONGOK MENGGUNAKAN SISTEM ZEOLIT TERAKTIVASI DAN TERIMPREGNASI TiO2 |
title_full |
PENURUNAN KADAR AMONIA, NITRIT DAN NITRAT LIMBAH CAIR INDUSTRI TAHU DI DESA KALISARI, CILONGOK MENGGUNAKAN SISTEM ZEOLIT TERAKTIVASI DAN TERIMPREGNASI TiO2 |
title_fullStr |
PENURUNAN KADAR AMONIA, NITRIT DAN NITRAT LIMBAH CAIR INDUSTRI TAHU DI DESA KALISARI, CILONGOK MENGGUNAKAN SISTEM ZEOLIT TERAKTIVASI DAN TERIMPREGNASI TiO2 |
title_full_unstemmed |
PENURUNAN KADAR AMONIA, NITRIT DAN NITRAT LIMBAH CAIR INDUSTRI TAHU DI DESA KALISARI, CILONGOK MENGGUNAKAN SISTEM ZEOLIT TERAKTIVASI DAN TERIMPREGNASI TiO2 |
title_sort |
penurunan kadar amonia, nitrit dan nitrat limbah cair industri tahu di desa kalisari, cilongok menggunakan sistem zeolit teraktivasi dan terimpregnasi tio2 |
publisher |
Jenderal Soedirman University |
series |
Molekul |
issn |
1907-9761 1907-9761 |
publishDate |
2007-11-01 |
description |
Treatment of the tofu industry wastewater by activated zeolite system and TiO2 impregnated zeolite system was conducted. The systems are one of the alternatif method in decreasing ammonia, nitrite and nitrate contents in tofu industry wastewater. The research was aimed to decide the optimum loading rate of the wastewater into zeolite system. The loading rate variety are: 160, 240, 320, 400 and 480 L m-2 day-1. Then also determined the efficiency of zeolite system to decrease ammonia, nitrite and nitrate contents in tofu industry wastewater by using the optimum loading rate. The result of the research showed that these three zeolite systems were able to decrease ammonia, nitrite and nitrate contents in tofu industry wastewater by optimum loading rate 320 L m-2 day-1. The efficiency of these three zeolite systems in decreasing the ammonia, nitrite and nitrate contents in tofu industry wastewater respectively were 74.96%, 70.36%, 65.57% for acid activated zeolite system, 84.26%, 72.36%, 76.36% for base activated zeolite system, and 75.50%, 70.35%, 71.71% for TiO2 impregnated zeolite system. From three of those zeolite systems, base activated zeolite system was the highest efficiency in decreasing the ammonia, nitrite and nitrate contents in tofu industry wastewater. |
topic |
Zeolite tofu industry ammonia nitrite nitrate. |
url |
http://www.jmolekul.com/?download=2.2.44.pdf |
work_keys_str_mv |
AT irmanto penurunankadaramonianitritdannitratlimbahcairindustritahudidesakalisaricilongokmenggunakansistemzeolitteraktivasidanterimpregnasitio2 AT suyata penurunankadaramonianitritdannitratlimbahcairindustritahudidesakalisaricilongokmenggunakansistemzeolitteraktivasidanterimpregnasitio2 |
_version_ |
1725226884965335040 |