Usability of Rapid Cholera Detection Device (OmniVis) for Water Quality Workers in Bangladesh: Iterative Convergent Mixed Methods Study

BackgroundCholera poses a significant global health burden. In Bangladesh, cholera is endemic and causes more than 100,000 cases each year. Established environmental reservoirs leave millions at risk of infection through the consumption of contaminated water. The Global Task...

Full description

Bibliographic Details
Main Authors: Rager, Theresa L, Koepfli, Cristian, Khan, Wasif A, Ahmed, Sabeena, Mahmud, Zahid Hayat, Clayton, Katherine N
Format: Article
Language:English
Published: JMIR Publications 2021-05-01
Series:Journal of Medical Internet Research
Online Access:https://www.jmir.org/2021/5/e22973
id doaj-d7dee2e48bd54ae086cc20b7a1b8f97c
record_format Article
spelling doaj-d7dee2e48bd54ae086cc20b7a1b8f97c2021-05-12T14:01:09ZengJMIR PublicationsJournal of Medical Internet Research1438-88712021-05-01235e2297310.2196/22973Usability of Rapid Cholera Detection Device (OmniVis) for Water Quality Workers in Bangladesh: Iterative Convergent Mixed Methods StudyRager, Theresa LKoepfli, CristianKhan, Wasif AAhmed, SabeenaMahmud, Zahid HayatClayton, Katherine N BackgroundCholera poses a significant global health burden. In Bangladesh, cholera is endemic and causes more than 100,000 cases each year. Established environmental reservoirs leave millions at risk of infection through the consumption of contaminated water. The Global Task Force for Cholera Control has called for increased environmental surveillance to detect contaminated water sources prior to human infection in an effort to reduce cases and deaths. The OmniVis rapid cholera detection device uses loop-mediated isothermal amplification and particle diffusometry detection methods integrated into a handheld hardware device that attaches to an iPhone 6 to identify and map contaminated water sources. ObjectiveThe aim of this study was to evaluate the usability of the OmniVis device with targeted end users to advance the iterative prototyping process and ultimately design a device that easily integrates into users’ workflow. MethodsWater quality workers were trained to use the device and subsequently completed an independent device trial and usability questionnaire. Pretraining and posttraining knowledge assessments were administered to ensure training quality did not confound trial and questionnaire ResultsDevice trials identified common user errors and device malfunctions including incorrect test kit insertion and device powering issues. We did not observe meaningful differences in user errors or device malfunctions accumulated per participant across demographic groups. Over 25 trials, the mean time to complete a test was 47 minutes, a significant reduction compared with laboratory protocols, which take approximately 3 days. Overall, participants found the device easy to use and expressed confidence and comfort in using the device independently. ConclusionsThese results are used to advance the iterative prototyping process of the OmniVis rapid cholera detection device so it can achieve user uptake, workflow integration, and scale to ultimately impact cholera control and elimination strategies. We hope this methodology will promote robust usability evaluations of rapid pathogen detection technologies in device development.https://www.jmir.org/2021/5/e22973
collection DOAJ
language English
format Article
sources DOAJ
author Rager, Theresa L
Koepfli, Cristian
Khan, Wasif A
Ahmed, Sabeena
Mahmud, Zahid Hayat
Clayton, Katherine N
spellingShingle Rager, Theresa L
Koepfli, Cristian
Khan, Wasif A
Ahmed, Sabeena
Mahmud, Zahid Hayat
Clayton, Katherine N
Usability of Rapid Cholera Detection Device (OmniVis) for Water Quality Workers in Bangladesh: Iterative Convergent Mixed Methods Study
Journal of Medical Internet Research
author_facet Rager, Theresa L
Koepfli, Cristian
Khan, Wasif A
Ahmed, Sabeena
Mahmud, Zahid Hayat
Clayton, Katherine N
author_sort Rager, Theresa L
title Usability of Rapid Cholera Detection Device (OmniVis) for Water Quality Workers in Bangladesh: Iterative Convergent Mixed Methods Study
title_short Usability of Rapid Cholera Detection Device (OmniVis) for Water Quality Workers in Bangladesh: Iterative Convergent Mixed Methods Study
title_full Usability of Rapid Cholera Detection Device (OmniVis) for Water Quality Workers in Bangladesh: Iterative Convergent Mixed Methods Study
title_fullStr Usability of Rapid Cholera Detection Device (OmniVis) for Water Quality Workers in Bangladesh: Iterative Convergent Mixed Methods Study
title_full_unstemmed Usability of Rapid Cholera Detection Device (OmniVis) for Water Quality Workers in Bangladesh: Iterative Convergent Mixed Methods Study
title_sort usability of rapid cholera detection device (omnivis) for water quality workers in bangladesh: iterative convergent mixed methods study
publisher JMIR Publications
series Journal of Medical Internet Research
issn 1438-8871
publishDate 2021-05-01
description BackgroundCholera poses a significant global health burden. In Bangladesh, cholera is endemic and causes more than 100,000 cases each year. Established environmental reservoirs leave millions at risk of infection through the consumption of contaminated water. The Global Task Force for Cholera Control has called for increased environmental surveillance to detect contaminated water sources prior to human infection in an effort to reduce cases and deaths. The OmniVis rapid cholera detection device uses loop-mediated isothermal amplification and particle diffusometry detection methods integrated into a handheld hardware device that attaches to an iPhone 6 to identify and map contaminated water sources. ObjectiveThe aim of this study was to evaluate the usability of the OmniVis device with targeted end users to advance the iterative prototyping process and ultimately design a device that easily integrates into users’ workflow. MethodsWater quality workers were trained to use the device and subsequently completed an independent device trial and usability questionnaire. Pretraining and posttraining knowledge assessments were administered to ensure training quality did not confound trial and questionnaire ResultsDevice trials identified common user errors and device malfunctions including incorrect test kit insertion and device powering issues. We did not observe meaningful differences in user errors or device malfunctions accumulated per participant across demographic groups. Over 25 trials, the mean time to complete a test was 47 minutes, a significant reduction compared with laboratory protocols, which take approximately 3 days. Overall, participants found the device easy to use and expressed confidence and comfort in using the device independently. ConclusionsThese results are used to advance the iterative prototyping process of the OmniVis rapid cholera detection device so it can achieve user uptake, workflow integration, and scale to ultimately impact cholera control and elimination strategies. We hope this methodology will promote robust usability evaluations of rapid pathogen detection technologies in device development.
url https://www.jmir.org/2021/5/e22973
work_keys_str_mv AT ragertheresal usabilityofrapidcholeradetectiondeviceomnivisforwaterqualityworkersinbangladeshiterativeconvergentmixedmethodsstudy
AT koepflicristian usabilityofrapidcholeradetectiondeviceomnivisforwaterqualityworkersinbangladeshiterativeconvergentmixedmethodsstudy
AT khanwasifa usabilityofrapidcholeradetectiondeviceomnivisforwaterqualityworkersinbangladeshiterativeconvergentmixedmethodsstudy
AT ahmedsabeena usabilityofrapidcholeradetectiondeviceomnivisforwaterqualityworkersinbangladeshiterativeconvergentmixedmethodsstudy
AT mahmudzahidhayat usabilityofrapidcholeradetectiondeviceomnivisforwaterqualityworkersinbangladeshiterativeconvergentmixedmethodsstudy
AT claytonkatherinen usabilityofrapidcholeradetectiondeviceomnivisforwaterqualityworkersinbangladeshiterativeconvergentmixedmethodsstudy
_version_ 1721443064648564736