Strength properties of coated E-glass fibres in concrete
Test results obtained by studying the influence of epoxy coated E-glass fibre composites on the compressive and splitting tensile strengths of concrete are reported in the paper. Three grades of concrete and varying fibre volume fractions (0.5 %, 1 %, 1.5 % and 2 %) were used as test variables. It w...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Croatian Association of Civil Engineers
2016-10-01
|
Series: | Građevinar |
Online Access: | https://doi.org/10.14256/JCE.1335.2015 |
Summary: | Test results obtained by studying the influence of epoxy coated E-glass fibre composites on the compressive and splitting tensile strengths of concrete are reported in the paper. Three grades of concrete and varying fibre volume fractions (0.5 %, 1 %, 1.5 % and 2 %) were used as test variables. It was observed that the maximum compressive strength was attained for the fibre volume fraction of 1.5%, whereas the splitting tensile strength was found to increase with an increase in the fibre volume fraction. Based on the test results, a mathematical model was developed using regression analysis. |
---|---|