On the conversion of dose to bone to dose to water in radiotherapy treatment planning systems

Background and purpose: Conversion factors between dose to medium (Dm,m) and dose to water (Dw,w) provided by treatment planning systems that model the patient as water with variable electron density are currently based on stopping power ratios. In the current paper it will be illustrated that this...

Full description

Bibliographic Details
Main Authors: Nick Reynaert, Frederik Crop, Edmond Sterpin, Iwan Kawrakow, Hugo Palmans
Format: Article
Language:English
Published: Elsevier 2018-01-01
Series:Physics and Imaging in Radiation Oncology
Online Access:http://www.sciencedirect.com/science/article/pii/S2405631617300404
id doaj-d7bebde1e74b4dcfba2f4432722f2b7a
record_format Article
spelling doaj-d7bebde1e74b4dcfba2f4432722f2b7a2020-11-25T00:47:08ZengElsevierPhysics and Imaging in Radiation Oncology2405-63162018-01-0152630On the conversion of dose to bone to dose to water in radiotherapy treatment planning systemsNick Reynaert0Frederik Crop1Edmond Sterpin2Iwan Kawrakow3Hugo Palmans4Institut Jules Bordet, Belgium; Centre Oscar Lambret, Lille, France; Corresponding author at: Institut Jules Bordet, 121 bd de Waterloo laan, 1000 Brussels, Belgium.Centre Oscar Lambret, Lille, FranceKatholieke Universiteit Leuven, Department of Oncology, Laboratory of Experimental Radiotherapy, Leuven, Belgium; Université catholique de Louvain, Institut de Recherche expérimentale et Clinique, Center of Molecular Imaging, Radiotherapy and Oncology, Brussels, BelgiumViewray, 2 Thermo Fisher Way, Oakwood Village, OH 44146, USANational Physics Laboratory, Acoustics and Ionising Radiation Division, Teddington, TW 11 0LW, UK; EBG MedAustron GmbH, Medical Physics Department, Wiener Neustadt A-2700, AustriaBackground and purpose: Conversion factors between dose to medium (Dm,m) and dose to water (Dw,w) provided by treatment planning systems that model the patient as water with variable electron density are currently based on stopping power ratios. In the current paper it will be illustrated that this conversion method is not correct. Materials and methods: Monte Carlo calculations were performed in a phantom consisting of a 2 cm bone layer surrounded by water. Dw,w was obtained by modelling the bone layer as water with the electron density of bone. Conversion factors between Dw,w and Dm,m were obtained and compared to stopping power ratios and ratios of mass-energy absorption coefficients in regions of electronic equilibrium and interfaces. Calculations were performed for 6 MV and 20 MV photon beams. Results: In the region of electronic equilibrium the stopping power ratio of water to bone (1.11) largely overestimates the conversion obtained using the Monte Carlo calculations (1.06). In that region the MC dose conversion corresponds to the ratio of mass energy absorption coefficients. Near the water to bone interface, the MC ratio cannot be determined from stopping powers or mass energy absorption coefficients. Conclusion: Stopping power ratios cannot be used for conversion from Dm,m to Dw,w provided by treatment planning systems that model the patient as water with variable electron density, either in regions of electronic equilibrium or near interfaces. In regions of electronic equilibrium mass energy absorption coefficient ratios should be used. Conversions at interfaces require detailed MC calculations. Keywords: Dose to water, Monte Carlo, Dosimetry, TPS comparisonhttp://www.sciencedirect.com/science/article/pii/S2405631617300404
collection DOAJ
language English
format Article
sources DOAJ
author Nick Reynaert
Frederik Crop
Edmond Sterpin
Iwan Kawrakow
Hugo Palmans
spellingShingle Nick Reynaert
Frederik Crop
Edmond Sterpin
Iwan Kawrakow
Hugo Palmans
On the conversion of dose to bone to dose to water in radiotherapy treatment planning systems
Physics and Imaging in Radiation Oncology
author_facet Nick Reynaert
Frederik Crop
Edmond Sterpin
Iwan Kawrakow
Hugo Palmans
author_sort Nick Reynaert
title On the conversion of dose to bone to dose to water in radiotherapy treatment planning systems
title_short On the conversion of dose to bone to dose to water in radiotherapy treatment planning systems
title_full On the conversion of dose to bone to dose to water in radiotherapy treatment planning systems
title_fullStr On the conversion of dose to bone to dose to water in radiotherapy treatment planning systems
title_full_unstemmed On the conversion of dose to bone to dose to water in radiotherapy treatment planning systems
title_sort on the conversion of dose to bone to dose to water in radiotherapy treatment planning systems
publisher Elsevier
series Physics and Imaging in Radiation Oncology
issn 2405-6316
publishDate 2018-01-01
description Background and purpose: Conversion factors between dose to medium (Dm,m) and dose to water (Dw,w) provided by treatment planning systems that model the patient as water with variable electron density are currently based on stopping power ratios. In the current paper it will be illustrated that this conversion method is not correct. Materials and methods: Monte Carlo calculations were performed in a phantom consisting of a 2 cm bone layer surrounded by water. Dw,w was obtained by modelling the bone layer as water with the electron density of bone. Conversion factors between Dw,w and Dm,m were obtained and compared to stopping power ratios and ratios of mass-energy absorption coefficients in regions of electronic equilibrium and interfaces. Calculations were performed for 6 MV and 20 MV photon beams. Results: In the region of electronic equilibrium the stopping power ratio of water to bone (1.11) largely overestimates the conversion obtained using the Monte Carlo calculations (1.06). In that region the MC dose conversion corresponds to the ratio of mass energy absorption coefficients. Near the water to bone interface, the MC ratio cannot be determined from stopping powers or mass energy absorption coefficients. Conclusion: Stopping power ratios cannot be used for conversion from Dm,m to Dw,w provided by treatment planning systems that model the patient as water with variable electron density, either in regions of electronic equilibrium or near interfaces. In regions of electronic equilibrium mass energy absorption coefficient ratios should be used. Conversions at interfaces require detailed MC calculations. Keywords: Dose to water, Monte Carlo, Dosimetry, TPS comparison
url http://www.sciencedirect.com/science/article/pii/S2405631617300404
work_keys_str_mv AT nickreynaert ontheconversionofdosetobonetodosetowaterinradiotherapytreatmentplanningsystems
AT frederikcrop ontheconversionofdosetobonetodosetowaterinradiotherapytreatmentplanningsystems
AT edmondsterpin ontheconversionofdosetobonetodosetowaterinradiotherapytreatmentplanningsystems
AT iwankawrakow ontheconversionofdosetobonetodosetowaterinradiotherapytreatmentplanningsystems
AT hugopalmans ontheconversionofdosetobonetodosetowaterinradiotherapytreatmentplanningsystems
_version_ 1725261599711690752