On the conversion of dose to bone to dose to water in radiotherapy treatment planning systems
Background and purpose: Conversion factors between dose to medium (Dm,m) and dose to water (Dw,w) provided by treatment planning systems that model the patient as water with variable electron density are currently based on stopping power ratios. In the current paper it will be illustrated that this...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2018-01-01
|
Series: | Physics and Imaging in Radiation Oncology |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2405631617300404 |
id |
doaj-d7bebde1e74b4dcfba2f4432722f2b7a |
---|---|
record_format |
Article |
spelling |
doaj-d7bebde1e74b4dcfba2f4432722f2b7a2020-11-25T00:47:08ZengElsevierPhysics and Imaging in Radiation Oncology2405-63162018-01-0152630On the conversion of dose to bone to dose to water in radiotherapy treatment planning systemsNick Reynaert0Frederik Crop1Edmond Sterpin2Iwan Kawrakow3Hugo Palmans4Institut Jules Bordet, Belgium; Centre Oscar Lambret, Lille, France; Corresponding author at: Institut Jules Bordet, 121 bd de Waterloo laan, 1000 Brussels, Belgium.Centre Oscar Lambret, Lille, FranceKatholieke Universiteit Leuven, Department of Oncology, Laboratory of Experimental Radiotherapy, Leuven, Belgium; Université catholique de Louvain, Institut de Recherche expérimentale et Clinique, Center of Molecular Imaging, Radiotherapy and Oncology, Brussels, BelgiumViewray, 2 Thermo Fisher Way, Oakwood Village, OH 44146, USANational Physics Laboratory, Acoustics and Ionising Radiation Division, Teddington, TW 11 0LW, UK; EBG MedAustron GmbH, Medical Physics Department, Wiener Neustadt A-2700, AustriaBackground and purpose: Conversion factors between dose to medium (Dm,m) and dose to water (Dw,w) provided by treatment planning systems that model the patient as water with variable electron density are currently based on stopping power ratios. In the current paper it will be illustrated that this conversion method is not correct. Materials and methods: Monte Carlo calculations were performed in a phantom consisting of a 2 cm bone layer surrounded by water. Dw,w was obtained by modelling the bone layer as water with the electron density of bone. Conversion factors between Dw,w and Dm,m were obtained and compared to stopping power ratios and ratios of mass-energy absorption coefficients in regions of electronic equilibrium and interfaces. Calculations were performed for 6 MV and 20 MV photon beams. Results: In the region of electronic equilibrium the stopping power ratio of water to bone (1.11) largely overestimates the conversion obtained using the Monte Carlo calculations (1.06). In that region the MC dose conversion corresponds to the ratio of mass energy absorption coefficients. Near the water to bone interface, the MC ratio cannot be determined from stopping powers or mass energy absorption coefficients. Conclusion: Stopping power ratios cannot be used for conversion from Dm,m to Dw,w provided by treatment planning systems that model the patient as water with variable electron density, either in regions of electronic equilibrium or near interfaces. In regions of electronic equilibrium mass energy absorption coefficient ratios should be used. Conversions at interfaces require detailed MC calculations. Keywords: Dose to water, Monte Carlo, Dosimetry, TPS comparisonhttp://www.sciencedirect.com/science/article/pii/S2405631617300404 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Nick Reynaert Frederik Crop Edmond Sterpin Iwan Kawrakow Hugo Palmans |
spellingShingle |
Nick Reynaert Frederik Crop Edmond Sterpin Iwan Kawrakow Hugo Palmans On the conversion of dose to bone to dose to water in radiotherapy treatment planning systems Physics and Imaging in Radiation Oncology |
author_facet |
Nick Reynaert Frederik Crop Edmond Sterpin Iwan Kawrakow Hugo Palmans |
author_sort |
Nick Reynaert |
title |
On the conversion of dose to bone to dose to water in radiotherapy treatment planning systems |
title_short |
On the conversion of dose to bone to dose to water in radiotherapy treatment planning systems |
title_full |
On the conversion of dose to bone to dose to water in radiotherapy treatment planning systems |
title_fullStr |
On the conversion of dose to bone to dose to water in radiotherapy treatment planning systems |
title_full_unstemmed |
On the conversion of dose to bone to dose to water in radiotherapy treatment planning systems |
title_sort |
on the conversion of dose to bone to dose to water in radiotherapy treatment planning systems |
publisher |
Elsevier |
series |
Physics and Imaging in Radiation Oncology |
issn |
2405-6316 |
publishDate |
2018-01-01 |
description |
Background and purpose: Conversion factors between dose to medium (Dm,m) and dose to water (Dw,w) provided by treatment planning systems that model the patient as water with variable electron density are currently based on stopping power ratios. In the current paper it will be illustrated that this conversion method is not correct. Materials and methods: Monte Carlo calculations were performed in a phantom consisting of a 2 cm bone layer surrounded by water. Dw,w was obtained by modelling the bone layer as water with the electron density of bone. Conversion factors between Dw,w and Dm,m were obtained and compared to stopping power ratios and ratios of mass-energy absorption coefficients in regions of electronic equilibrium and interfaces. Calculations were performed for 6 MV and 20 MV photon beams. Results: In the region of electronic equilibrium the stopping power ratio of water to bone (1.11) largely overestimates the conversion obtained using the Monte Carlo calculations (1.06). In that region the MC dose conversion corresponds to the ratio of mass energy absorption coefficients. Near the water to bone interface, the MC ratio cannot be determined from stopping powers or mass energy absorption coefficients. Conclusion: Stopping power ratios cannot be used for conversion from Dm,m to Dw,w provided by treatment planning systems that model the patient as water with variable electron density, either in regions of electronic equilibrium or near interfaces. In regions of electronic equilibrium mass energy absorption coefficient ratios should be used. Conversions at interfaces require detailed MC calculations. Keywords: Dose to water, Monte Carlo, Dosimetry, TPS comparison |
url |
http://www.sciencedirect.com/science/article/pii/S2405631617300404 |
work_keys_str_mv |
AT nickreynaert ontheconversionofdosetobonetodosetowaterinradiotherapytreatmentplanningsystems AT frederikcrop ontheconversionofdosetobonetodosetowaterinradiotherapytreatmentplanningsystems AT edmondsterpin ontheconversionofdosetobonetodosetowaterinradiotherapytreatmentplanningsystems AT iwankawrakow ontheconversionofdosetobonetodosetowaterinradiotherapytreatmentplanningsystems AT hugopalmans ontheconversionofdosetobonetodosetowaterinradiotherapytreatmentplanningsystems |
_version_ |
1725261599711690752 |