An Investigation of the Behavioral Characteristics of Higher- and Lower-Temperature Group Families in a Condominium Equipped with a HEMS System

A home energy management system (HEMS) shows the energy used indoors so that the energy waste can be easily identified and reduced. Thermal comfort is related to the trend of energy use in buildings. We conducted a survey in a condominium equipped with a HEMS to determine the indoor thermal environm...

Full description

Bibliographic Details
Main Authors: Rajan KC, Hom Bahadur Rijal, Masanori Shukuya, Kazui Yoshida
Format: Article
Language:English
Published: MDPI AG 2018-12-01
Series:Buildings
Subjects:
Online Access:http://www.mdpi.com/2075-5309/9/1/4
id doaj-d742448d2f4a4ac5aeba7b4b76cd640b
record_format Article
spelling doaj-d742448d2f4a4ac5aeba7b4b76cd640b2020-11-25T02:00:25ZengMDPI AGBuildings2075-53092018-12-0191410.3390/buildings9010004buildings9010004An Investigation of the Behavioral Characteristics of Higher- and Lower-Temperature Group Families in a Condominium Equipped with a HEMS SystemRajan KC0Hom Bahadur Rijal1Masanori Shukuya2Kazui Yoshida3Graduate School of Environmental and Information Studies, Tokyo City University, Yokohama 224-8551, JapanGraduate School of Environmental and Information Studies, Tokyo City University, Yokohama 224-8551, JapanGraduate School of Environmental and Information Studies, Tokyo City University, Yokohama 224-8551, JapanTokyu Real Estate Co.Ltd, Next Generation Engineering Research Center, Tokyo 107-0062, JapanA home energy management system (HEMS) shows the energy used indoors so that the energy waste can be easily identified and reduced. Thermal comfort is related to the trend of energy use in buildings. We conducted a survey in a condominium equipped with a HEMS to determine the indoor thermal environment and various behaviors of the occupants taken for thermal comfort adjustment. The results showed that there is a large variation of indoor air temperatures according to season, floor and flat. We categorized families into two groups, one with higher and the other with lower average indoor temperatures. The indoor air temperature of the higher temperature group in summer was found to be higher than the recommended indoor temperature during the summer season in Japan. The higher temperature group tended to adopt behaviors, such as window opening and using a fan more often, than the lower temperature group. Due to the moderately high insulating levels in the building surveyed, the indoor air temperature of both groups was not low in winter. Heating was used less and irregular. The overall results indicate that the groups of families behaved differently to adjust the indoor thermal environment even though they were equipped with the same HEMS system.http://www.mdpi.com/2075-5309/9/1/4HEMSindoor environmentair temperaturerelative humidityoccupants’ behaviors
collection DOAJ
language English
format Article
sources DOAJ
author Rajan KC
Hom Bahadur Rijal
Masanori Shukuya
Kazui Yoshida
spellingShingle Rajan KC
Hom Bahadur Rijal
Masanori Shukuya
Kazui Yoshida
An Investigation of the Behavioral Characteristics of Higher- and Lower-Temperature Group Families in a Condominium Equipped with a HEMS System
Buildings
HEMS
indoor environment
air temperature
relative humidity
occupants’ behaviors
author_facet Rajan KC
Hom Bahadur Rijal
Masanori Shukuya
Kazui Yoshida
author_sort Rajan KC
title An Investigation of the Behavioral Characteristics of Higher- and Lower-Temperature Group Families in a Condominium Equipped with a HEMS System
title_short An Investigation of the Behavioral Characteristics of Higher- and Lower-Temperature Group Families in a Condominium Equipped with a HEMS System
title_full An Investigation of the Behavioral Characteristics of Higher- and Lower-Temperature Group Families in a Condominium Equipped with a HEMS System
title_fullStr An Investigation of the Behavioral Characteristics of Higher- and Lower-Temperature Group Families in a Condominium Equipped with a HEMS System
title_full_unstemmed An Investigation of the Behavioral Characteristics of Higher- and Lower-Temperature Group Families in a Condominium Equipped with a HEMS System
title_sort investigation of the behavioral characteristics of higher- and lower-temperature group families in a condominium equipped with a hems system
publisher MDPI AG
series Buildings
issn 2075-5309
publishDate 2018-12-01
description A home energy management system (HEMS) shows the energy used indoors so that the energy waste can be easily identified and reduced. Thermal comfort is related to the trend of energy use in buildings. We conducted a survey in a condominium equipped with a HEMS to determine the indoor thermal environment and various behaviors of the occupants taken for thermal comfort adjustment. The results showed that there is a large variation of indoor air temperatures according to season, floor and flat. We categorized families into two groups, one with higher and the other with lower average indoor temperatures. The indoor air temperature of the higher temperature group in summer was found to be higher than the recommended indoor temperature during the summer season in Japan. The higher temperature group tended to adopt behaviors, such as window opening and using a fan more often, than the lower temperature group. Due to the moderately high insulating levels in the building surveyed, the indoor air temperature of both groups was not low in winter. Heating was used less and irregular. The overall results indicate that the groups of families behaved differently to adjust the indoor thermal environment even though they were equipped with the same HEMS system.
topic HEMS
indoor environment
air temperature
relative humidity
occupants’ behaviors
url http://www.mdpi.com/2075-5309/9/1/4
work_keys_str_mv AT rajankc aninvestigationofthebehavioralcharacteristicsofhigherandlowertemperaturegroupfamiliesinacondominiumequippedwithahemssystem
AT hombahadurrijal aninvestigationofthebehavioralcharacteristicsofhigherandlowertemperaturegroupfamiliesinacondominiumequippedwithahemssystem
AT masanorishukuya aninvestigationofthebehavioralcharacteristicsofhigherandlowertemperaturegroupfamiliesinacondominiumequippedwithahemssystem
AT kazuiyoshida aninvestigationofthebehavioralcharacteristicsofhigherandlowertemperaturegroupfamiliesinacondominiumequippedwithahemssystem
AT rajankc investigationofthebehavioralcharacteristicsofhigherandlowertemperaturegroupfamiliesinacondominiumequippedwithahemssystem
AT hombahadurrijal investigationofthebehavioralcharacteristicsofhigherandlowertemperaturegroupfamiliesinacondominiumequippedwithahemssystem
AT masanorishukuya investigationofthebehavioralcharacteristicsofhigherandlowertemperaturegroupfamiliesinacondominiumequippedwithahemssystem
AT kazuiyoshida investigationofthebehavioralcharacteristicsofhigherandlowertemperaturegroupfamiliesinacondominiumequippedwithahemssystem
_version_ 1724960637555048448