OPTIMIZATION OF FLOCCULAR CLEANING AND DRAINAGE OF THIN DISPERSED SLUDGES

The efficiency of solid phase retention and dehydration of finely dispersed products of a coal processing plant and a metallurgical enterprise on the module for cleaning and dewatering sludge is investigated. A technique for selecting the operating parameters of equipment based on the determination...

Full description

Bibliographic Details
Main Authors: Oleksii Shestopalov, Oleksandr Briankin, Nadegda Rykusova, Oksana Hetta, Valentina Raiko, Musii Tseitlin
Format: Article
Language:English
Published: Scientific Route OÜ 2020-05-01
Series:EUREKA: Physics and Engineering
Subjects:
Online Access:http://journal.eu-jr.eu/engineering/article/view/15
id doaj-d734d45f9d444387a5ae1d7b5ce6f2ad
record_format Article
spelling doaj-d734d45f9d444387a5ae1d7b5ce6f2ad2020-11-25T01:38:26ZengScientific Route OÜEUREKA: Physics and Engineering2461-42542461-42622020-05-013758610.21303/2461-4262.2020.00123915OPTIMIZATION OF FLOCCULAR CLEANING AND DRAINAGE OF THIN DISPERSED SLUDGESOleksii Shestopalov0Oleksandr Briankin1Nadegda Rykusova2Oksana Hetta3Valentina Raiko4Musii Tseitlin5National Technical University "Kharkiv Polytechnic Institute"National Technical University "Kharkiv Polytechnic Institute"National Technical University "Kharkiv Polytechnic Institute"National Technical University "Kharkiv Polytechnic Institute"National Technical University "Kharkiv Polytechnic Institute"National Technical University "Kharkiv Polytechnic Institute"The efficiency of solid phase retention and dehydration of finely dispersed products of a coal processing plant and a metallurgical enterprise on the module for cleaning and dewatering sludge is investigated. A technique for selecting the operating parameters of equipment based on the determination of the strength criterion of flocs is proposed. A methodology for technological tests has been developed to control the flocculation process and optimize the flow of flocculant depending on the concentration of the solid phase. Industrial tests on the module for wastewater treatment and sludge dewatering using flocculants proved the effectiveness of the developed methodology. It is shown that the conditions for conducting tests on flocculation should correspond to the operating conditions of the circuit apparatus for cleaning and dewatering sludge. These conditions include sludge performance, sludge flow rate in the cross section of pipes and apparatuses, and the flow time from the flocculator to the centrifuge. During the testing of the Module, the solids retention efficiency of 97–99 % was achieved with the strength criteria of flocs in front of a centrifuge of 2–2.5 mm/s. The conditions for the high efficiency of the apparatus chain are the optimization of the aggregation process itself. It is revealed that for the formation of strong flocs it is necessary to regulate the concentration of the solid phase. For coal sludge, the concentration of the solid phase before the flocculant is fed must be maintained no higher than 50–60 g/l, and for gas treatment sludge – no higher than 20–25 g/l. Correction of the concentration of sludge before the flocculator is possible by diluting it with clarified water to the optimum concentration for aggregation. It is found that the moisture content of the sediment and the efficiency of the retention of the solid phase depend on the strength criterion of the flocs. Therefore, the optimization of the flocculant flow rate is possible by controlling and the residual floccule deposition rate after mechanical action in front of the dewatering equipment. The flocculant flow rate must be adjusted depending on the concentration of the solid phase in the sludge to achieve the desired criterion for the strength of the flocshttp://journal.eu-jr.eu/engineering/article/view/15fine sludge; aggregation; solid phase retention efficiency; sludge dewatering degree; centrifuge; flocculation
collection DOAJ
language English
format Article
sources DOAJ
author Oleksii Shestopalov
Oleksandr Briankin
Nadegda Rykusova
Oksana Hetta
Valentina Raiko
Musii Tseitlin
spellingShingle Oleksii Shestopalov
Oleksandr Briankin
Nadegda Rykusova
Oksana Hetta
Valentina Raiko
Musii Tseitlin
OPTIMIZATION OF FLOCCULAR CLEANING AND DRAINAGE OF THIN DISPERSED SLUDGES
EUREKA: Physics and Engineering
fine sludge; aggregation; solid phase retention efficiency; sludge dewatering degree; centrifuge; flocculation
author_facet Oleksii Shestopalov
Oleksandr Briankin
Nadegda Rykusova
Oksana Hetta
Valentina Raiko
Musii Tseitlin
author_sort Oleksii Shestopalov
title OPTIMIZATION OF FLOCCULAR CLEANING AND DRAINAGE OF THIN DISPERSED SLUDGES
title_short OPTIMIZATION OF FLOCCULAR CLEANING AND DRAINAGE OF THIN DISPERSED SLUDGES
title_full OPTIMIZATION OF FLOCCULAR CLEANING AND DRAINAGE OF THIN DISPERSED SLUDGES
title_fullStr OPTIMIZATION OF FLOCCULAR CLEANING AND DRAINAGE OF THIN DISPERSED SLUDGES
title_full_unstemmed OPTIMIZATION OF FLOCCULAR CLEANING AND DRAINAGE OF THIN DISPERSED SLUDGES
title_sort optimization of floccular cleaning and drainage of thin dispersed sludges
publisher Scientific Route OÜ
series EUREKA: Physics and Engineering
issn 2461-4254
2461-4262
publishDate 2020-05-01
description The efficiency of solid phase retention and dehydration of finely dispersed products of a coal processing plant and a metallurgical enterprise on the module for cleaning and dewatering sludge is investigated. A technique for selecting the operating parameters of equipment based on the determination of the strength criterion of flocs is proposed. A methodology for technological tests has been developed to control the flocculation process and optimize the flow of flocculant depending on the concentration of the solid phase. Industrial tests on the module for wastewater treatment and sludge dewatering using flocculants proved the effectiveness of the developed methodology. It is shown that the conditions for conducting tests on flocculation should correspond to the operating conditions of the circuit apparatus for cleaning and dewatering sludge. These conditions include sludge performance, sludge flow rate in the cross section of pipes and apparatuses, and the flow time from the flocculator to the centrifuge. During the testing of the Module, the solids retention efficiency of 97–99 % was achieved with the strength criteria of flocs in front of a centrifuge of 2–2.5 mm/s. The conditions for the high efficiency of the apparatus chain are the optimization of the aggregation process itself. It is revealed that for the formation of strong flocs it is necessary to regulate the concentration of the solid phase. For coal sludge, the concentration of the solid phase before the flocculant is fed must be maintained no higher than 50–60 g/l, and for gas treatment sludge – no higher than 20–25 g/l. Correction of the concentration of sludge before the flocculator is possible by diluting it with clarified water to the optimum concentration for aggregation. It is found that the moisture content of the sediment and the efficiency of the retention of the solid phase depend on the strength criterion of the flocs. Therefore, the optimization of the flocculant flow rate is possible by controlling and the residual floccule deposition rate after mechanical action in front of the dewatering equipment. The flocculant flow rate must be adjusted depending on the concentration of the solid phase in the sludge to achieve the desired criterion for the strength of the flocs
topic fine sludge; aggregation; solid phase retention efficiency; sludge dewatering degree; centrifuge; flocculation
url http://journal.eu-jr.eu/engineering/article/view/15
work_keys_str_mv AT oleksiishestopalov optimizationoffloccularcleaninganddrainageofthindispersedsludges
AT oleksandrbriankin optimizationoffloccularcleaninganddrainageofthindispersedsludges
AT nadegdarykusova optimizationoffloccularcleaninganddrainageofthindispersedsludges
AT oksanahetta optimizationoffloccularcleaninganddrainageofthindispersedsludges
AT valentinaraiko optimizationoffloccularcleaninganddrainageofthindispersedsludges
AT musiitseitlin optimizationoffloccularcleaninganddrainageofthindispersedsludges
_version_ 1725053864204304384