Dataset of Flow-Induced Vibrations on a Pipe Conveying Cold Water

Analysis of flow-induced pipe vibrations has been applied in a variety of applications, such as flowrate inference and leak detection. These applications are based on a functional relationship between the vibration features estimated in the pipe walls and the dynamics related to the flow of the subs...

Full description

Bibliographic Details
Main Authors: Francisco Villa, Cherlly Sánchez, Marcela Vallejo, Juan S. Botero-Valencia, Edilson Delgado-Trejos
Format: Article
Language:English
Published: MDPI AG 2021-09-01
Series:Data
Subjects:
Online Access:https://www.mdpi.com/2306-5729/6/9/100
id doaj-d726858fb1ab49759b2d88ecfcbb29a2
record_format Article
spelling doaj-d726858fb1ab49759b2d88ecfcbb29a22021-09-25T23:58:18ZengMDPI AGData2306-57292021-09-01610010010.3390/data6090100Dataset of Flow-Induced Vibrations on a Pipe Conveying Cold WaterFrancisco Villa0Cherlly Sánchez1Marcela Vallejo2Juan S. Botero-Valencia3Edilson Delgado-Trejos4Department of Quality and Production, Instituto Tecnológico Metropolitano ITM, Medellín 050034, ColombiaDepartment of Quality and Production, Instituto Tecnológico Metropolitano ITM, Medellín 050034, ColombiaMeasurement Analysis and Decision-Making Support Laboratory (AMYSOD Lab-Parque i), Department of Electronics and Telecommunications, Instituto Tecnológico Metropolitano ITM, Medellín 050034, ColombiaControl and Robotics Laboratory, Department of Mechatronics and Electromechanics, Instituto Tecnológico Metropolitano ITM, Medellín 050034, ColombiaMeasurement Analysis and Decision-Making Support Laboratory (AMYSOD Lab-Parque i), Quality Metrology and Production (CM&P) Research Group, Department of Quality and Production, Instituto Tecnológico Metropolitano ITM, Medellín 050034, ColombiaAnalysis of flow-induced pipe vibrations has been applied in a variety of applications, such as flowrate inference and leak detection. These applications are based on a functional relationship between the vibration features estimated in the pipe walls and the dynamics related to the flow of the substance. The dataset described in this document is comprised of signals acquired using an accelerometer attached to a pipe conveying cold water at specific flowrate values. Tests were carried out under numerals of the ISO 4064-1/2: 2016 standard and were performed in two measurement benches designed for flowmeter calibration, and a total of 80 flowrate values, from 25 L/h to 20,000 L/h, were considered. For each flowrate value, 3 to 6 samples were taken, so that the resulting dataset has a total of 382 signals that contain acceleration values in three axes and a timestamp in microseconds.https://www.mdpi.com/2306-5729/6/9/100flowratepipe vibration analysisinertial measurement unitmicro and macro measurement bench
collection DOAJ
language English
format Article
sources DOAJ
author Francisco Villa
Cherlly Sánchez
Marcela Vallejo
Juan S. Botero-Valencia
Edilson Delgado-Trejos
spellingShingle Francisco Villa
Cherlly Sánchez
Marcela Vallejo
Juan S. Botero-Valencia
Edilson Delgado-Trejos
Dataset of Flow-Induced Vibrations on a Pipe Conveying Cold Water
Data
flowrate
pipe vibration analysis
inertial measurement unit
micro and macro measurement bench
author_facet Francisco Villa
Cherlly Sánchez
Marcela Vallejo
Juan S. Botero-Valencia
Edilson Delgado-Trejos
author_sort Francisco Villa
title Dataset of Flow-Induced Vibrations on a Pipe Conveying Cold Water
title_short Dataset of Flow-Induced Vibrations on a Pipe Conveying Cold Water
title_full Dataset of Flow-Induced Vibrations on a Pipe Conveying Cold Water
title_fullStr Dataset of Flow-Induced Vibrations on a Pipe Conveying Cold Water
title_full_unstemmed Dataset of Flow-Induced Vibrations on a Pipe Conveying Cold Water
title_sort dataset of flow-induced vibrations on a pipe conveying cold water
publisher MDPI AG
series Data
issn 2306-5729
publishDate 2021-09-01
description Analysis of flow-induced pipe vibrations has been applied in a variety of applications, such as flowrate inference and leak detection. These applications are based on a functional relationship between the vibration features estimated in the pipe walls and the dynamics related to the flow of the substance. The dataset described in this document is comprised of signals acquired using an accelerometer attached to a pipe conveying cold water at specific flowrate values. Tests were carried out under numerals of the ISO 4064-1/2: 2016 standard and were performed in two measurement benches designed for flowmeter calibration, and a total of 80 flowrate values, from 25 L/h to 20,000 L/h, were considered. For each flowrate value, 3 to 6 samples were taken, so that the resulting dataset has a total of 382 signals that contain acceleration values in three axes and a timestamp in microseconds.
topic flowrate
pipe vibration analysis
inertial measurement unit
micro and macro measurement bench
url https://www.mdpi.com/2306-5729/6/9/100
work_keys_str_mv AT franciscovilla datasetofflowinducedvibrationsonapipeconveyingcoldwater
AT cherllysanchez datasetofflowinducedvibrationsonapipeconveyingcoldwater
AT marcelavallejo datasetofflowinducedvibrationsonapipeconveyingcoldwater
AT juansboterovalencia datasetofflowinducedvibrationsonapipeconveyingcoldwater
AT edilsondelgadotrejos datasetofflowinducedvibrationsonapipeconveyingcoldwater
_version_ 1717367419886895104