Absolute Single Cavity Length Interrogation of Fiber-Optic Compound Fabry–Perot Pressure Sensors Through a White Light Non-Scanning Correlation Method

A white light non-scanning correlation interrogation system was proposed and built to interrogate absolute length of the air cavity of fiber-optic compound Fabry–Perot pressure sensors for the extraction of pressure value. By carefully choosing thickness range and tilt angle of the optical...

Full description

Bibliographic Details
Main Authors: Zilong Guo, Wentao Lv, Wei Wang, Qingqing Chen, Xiongxing Zhang, Haibin Chen, Zhibo Ma
Format: Article
Language:English
Published: MDPI AG 2019-04-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/19/7/1628
Description
Summary:A white light non-scanning correlation interrogation system was proposed and built to interrogate absolute length of the air cavity of fiber-optic compound Fabry–Perot pressure sensors for the extraction of pressure value. By carefully choosing thickness range and tilt angle of the optical wedge used for cavity length matching, correlation interferometric signal of the basal cavity can be naturally filtered out. Based on peak positioning by Fourier transform, bandpass filtering in frequency domain, inverse Fourier transform back to time domain, envelope fitting and zero fringe finding through a gravity center method, cavity length can be determined with an accuracy of 0.04%. The system was used for the interrogation of a fiber-optic compound Fabry–Perot pressure sensor under different pressures. For a pressure range of 0.1~2.9 Mpa, the linear relationship between the air cavity length and the gas pressure imposed was successfully extracted.
ISSN:1424-8220