POWER LOSSES ASSESSMENT IN TRANSFORMERS AFTER THE NORMATIVE OPERATING PERIOD

The capacity losses values both loading and off-load are topmost parameters characterizing the distribution mains customers’ transformers operating effectiveness. Precise determination of the specified values facilitates substantiated choice of the optimizing procedures. The actuality of the given t...

Full description

Bibliographic Details
Main Authors: M. I. Fursanov, N. S. Petrashevich
Format: Article
Language:Russian
Published: Belarusian National Technical University 2015-10-01
Series:Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
Subjects:
Online Access:https://energy.bntu.by/jour/article/view/886
id doaj-d6fbd2de04454655a1e33b76198f4be6
record_format Article
spelling doaj-d6fbd2de04454655a1e33b76198f4be62021-07-29T08:45:38ZrusBelarusian National Technical UniversityIzvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika1029-74482414-03412015-10-01051623863POWER LOSSES ASSESSMENT IN TRANSFORMERS AFTER THE NORMATIVE OPERATING PERIODM. I. Fursanov0N. S. Petrashevich1Belarusian National Technical UniversityBelarusian National Technical UniversityThe capacity losses values both loading and off-load are topmost parameters characterizing the distribution mains customers’ transformers operating effectiveness. Precise determination of the specified values facilitates substantiated choice of the optimizing procedures. The actuality of the given topic increases owing to the fact that the modern electric grid utilizes plenty of the oil-transformers whose time in commission considerably exceeds the statutory 25 years. Under the conditions of continued operation the power-losses measurement according to the functioning guidelines does not seem always possible.The authors present an improved power-losses assessment technique based on the currently accepted thermal model of the oil-transformer. They indicate the deficiency of the existing technique and substantiate some of the changes in practical application of the mathematical model. The article makes an emphasis on peculiarities of the temperature changes in the oil-transformer and offers a prototype device of open architecture for realizing the improved technique of the power-losses measurement. The paper describes the device design features and functionality options and depicts its sketchy schematic. The authors note the potential of additional to assessing the power-losses volume, transmitting the obtained information to the dispatcher  via  GSM-connection  for  simplification  of  the  transformer  status  monitoring; as well as the capability of integrating the device into the system of the transformer thermal protection. The practical merit and application scope of the obtained results are in development and choice of the optimizing measures to be taken in the distributive electrical grids, e. g. the transformer replacement.https://energy.bntu.by/jour/article/view/886oil-immersed transformerpower lossesoperating period
collection DOAJ
language Russian
format Article
sources DOAJ
author M. I. Fursanov
N. S. Petrashevich
spellingShingle M. I. Fursanov
N. S. Petrashevich
POWER LOSSES ASSESSMENT IN TRANSFORMERS AFTER THE NORMATIVE OPERATING PERIOD
Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
oil-immersed transformer
power losses
operating period
author_facet M. I. Fursanov
N. S. Petrashevich
author_sort M. I. Fursanov
title POWER LOSSES ASSESSMENT IN TRANSFORMERS AFTER THE NORMATIVE OPERATING PERIOD
title_short POWER LOSSES ASSESSMENT IN TRANSFORMERS AFTER THE NORMATIVE OPERATING PERIOD
title_full POWER LOSSES ASSESSMENT IN TRANSFORMERS AFTER THE NORMATIVE OPERATING PERIOD
title_fullStr POWER LOSSES ASSESSMENT IN TRANSFORMERS AFTER THE NORMATIVE OPERATING PERIOD
title_full_unstemmed POWER LOSSES ASSESSMENT IN TRANSFORMERS AFTER THE NORMATIVE OPERATING PERIOD
title_sort power losses assessment in transformers after the normative operating period
publisher Belarusian National Technical University
series Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
issn 1029-7448
2414-0341
publishDate 2015-10-01
description The capacity losses values both loading and off-load are topmost parameters characterizing the distribution mains customers’ transformers operating effectiveness. Precise determination of the specified values facilitates substantiated choice of the optimizing procedures. The actuality of the given topic increases owing to the fact that the modern electric grid utilizes plenty of the oil-transformers whose time in commission considerably exceeds the statutory 25 years. Under the conditions of continued operation the power-losses measurement according to the functioning guidelines does not seem always possible.The authors present an improved power-losses assessment technique based on the currently accepted thermal model of the oil-transformer. They indicate the deficiency of the existing technique and substantiate some of the changes in practical application of the mathematical model. The article makes an emphasis on peculiarities of the temperature changes in the oil-transformer and offers a prototype device of open architecture for realizing the improved technique of the power-losses measurement. The paper describes the device design features and functionality options and depicts its sketchy schematic. The authors note the potential of additional to assessing the power-losses volume, transmitting the obtained information to the dispatcher  via  GSM-connection  for  simplification  of  the  transformer  status  monitoring; as well as the capability of integrating the device into the system of the transformer thermal protection. The practical merit and application scope of the obtained results are in development and choice of the optimizing measures to be taken in the distributive electrical grids, e. g. the transformer replacement.
topic oil-immersed transformer
power losses
operating period
url https://energy.bntu.by/jour/article/view/886