An Innovative Method of Assessing the Mechanical Axis Deviation in the Lower Limb in Standing Position

Introduction: Various methods of measuring mechanical axis deviation of lower limb have been described including radiographic and CT scanogram, intraoperative fluoroscopy with the use of an electrocautery cord. These methods determine the mechanical axis in a supine, non-weight bearing position....

Full description

Bibliographic Details
Main Authors: Jagannath Kamath, Raja Shekar Danda, Nikil Jayasheelan, Rohit Singh
Format: Article
Language:English
Published: JCDR Research and Publications Private Limited 2016-06-01
Series:Journal of Clinical and Diagnostic Research
Subjects:
Online Access:https://jcdr.net/articles/PDF/8042/17324_CE(RA1)_F(T)_PF1(ROAK)_PFA(AK)_PF2(PAG).pdf
id doaj-d65c0bd2d67b4d42b7003ab4fa2351b2
record_format Article
spelling doaj-d65c0bd2d67b4d42b7003ab4fa2351b22020-11-25T03:25:23ZengJCDR Research and Publications Private LimitedJournal of Clinical and Diagnostic Research2249-782X0973-709X2016-06-01106RC11RC1310.7860/JCDR/2016/17324.8042An Innovative Method of Assessing the Mechanical Axis Deviation in the Lower Limb in Standing PositionJagannath Kamath0Raja Shekar Danda1Nikil Jayasheelan2Rohit Singh3Professor, Department of Orthopaedics, Kasturba Medical College, Manipal University, Karnataka, Mangalore, India.Senior Resident, Department of Orthopaedics, Kasturba Medical College, Manipal University, Mangalore, Karnataka, India.Senior Resident, Department of Orthopaedics, Kasturba Medical College, Manipal University, Mangalore, Karnataka, India.Senior Resident, Department of Orthopaedics, Kasturba Medical College, Manipal University, Mangalore, Karnataka, India.Introduction: Various methods of measuring mechanical axis deviation of lower limb have been described including radiographic and CT scanogram, intraoperative fluoroscopy with the use of an electrocautery cord. These methods determine the mechanical axis in a supine, non-weight bearing position. Although long cassette standing radiographic view is used for the purpose but is not available at most centres. A dynamic method of determining the mechanical axis in a weight bearing position was devised in this study. Aim: The aim of the study was to describe a simpler and newer method in quantifying the mechanical axis deviation in places where full length cassettes for standing X rays are not available. Materials and Methods: A pilot study was conducted on 15 patients. The deviation from the mechanical axis was measured using a manually operated, hydraulic mechanism based, elevating scissor lift table. Patient was asked to stand erect over the elevating lift table with both patellae facing forward and C-arm image intensifier was positioned horizontally. Radiological markers were tied to a radio-opaque thread and placed at the centre of head of the femur and another at the centre of the tibio-talar joint. C-arm views of the hip, ankle and knee joint were taken to confirm the correct position of the marker by varying the height of the lift table. Results: The mechanical axis deviation values were recorded by measuring distance between the centre of the knee and radioopaque thread in cm. This was measured in each case both clinically and from the image on the monitor. The two values were found to be statistically same. Pain was measured on VAS. Mechanical axis deviation values and VAS score were found to be positively significantly correlated. Conclusion: This technique is dynamic, unique and accurate as compared to other methods for assessing mechanical axis deviation in a weight bearing position.https://jcdr.net/articles/PDF/8042/17324_CE(RA1)_F(T)_PF1(ROAK)_PFA(AK)_PF2(PAG).pdfc-arm imagingdeformitylateral compartment
collection DOAJ
language English
format Article
sources DOAJ
author Jagannath Kamath
Raja Shekar Danda
Nikil Jayasheelan
Rohit Singh
spellingShingle Jagannath Kamath
Raja Shekar Danda
Nikil Jayasheelan
Rohit Singh
An Innovative Method of Assessing the Mechanical Axis Deviation in the Lower Limb in Standing Position
Journal of Clinical and Diagnostic Research
c-arm imaging
deformity
lateral compartment
author_facet Jagannath Kamath
Raja Shekar Danda
Nikil Jayasheelan
Rohit Singh
author_sort Jagannath Kamath
title An Innovative Method of Assessing the Mechanical Axis Deviation in the Lower Limb in Standing Position
title_short An Innovative Method of Assessing the Mechanical Axis Deviation in the Lower Limb in Standing Position
title_full An Innovative Method of Assessing the Mechanical Axis Deviation in the Lower Limb in Standing Position
title_fullStr An Innovative Method of Assessing the Mechanical Axis Deviation in the Lower Limb in Standing Position
title_full_unstemmed An Innovative Method of Assessing the Mechanical Axis Deviation in the Lower Limb in Standing Position
title_sort innovative method of assessing the mechanical axis deviation in the lower limb in standing position
publisher JCDR Research and Publications Private Limited
series Journal of Clinical and Diagnostic Research
issn 2249-782X
0973-709X
publishDate 2016-06-01
description Introduction: Various methods of measuring mechanical axis deviation of lower limb have been described including radiographic and CT scanogram, intraoperative fluoroscopy with the use of an electrocautery cord. These methods determine the mechanical axis in a supine, non-weight bearing position. Although long cassette standing radiographic view is used for the purpose but is not available at most centres. A dynamic method of determining the mechanical axis in a weight bearing position was devised in this study. Aim: The aim of the study was to describe a simpler and newer method in quantifying the mechanical axis deviation in places where full length cassettes for standing X rays are not available. Materials and Methods: A pilot study was conducted on 15 patients. The deviation from the mechanical axis was measured using a manually operated, hydraulic mechanism based, elevating scissor lift table. Patient was asked to stand erect over the elevating lift table with both patellae facing forward and C-arm image intensifier was positioned horizontally. Radiological markers were tied to a radio-opaque thread and placed at the centre of head of the femur and another at the centre of the tibio-talar joint. C-arm views of the hip, ankle and knee joint were taken to confirm the correct position of the marker by varying the height of the lift table. Results: The mechanical axis deviation values were recorded by measuring distance between the centre of the knee and radioopaque thread in cm. This was measured in each case both clinically and from the image on the monitor. The two values were found to be statistically same. Pain was measured on VAS. Mechanical axis deviation values and VAS score were found to be positively significantly correlated. Conclusion: This technique is dynamic, unique and accurate as compared to other methods for assessing mechanical axis deviation in a weight bearing position.
topic c-arm imaging
deformity
lateral compartment
url https://jcdr.net/articles/PDF/8042/17324_CE(RA1)_F(T)_PF1(ROAK)_PFA(AK)_PF2(PAG).pdf
work_keys_str_mv AT jagannathkamath aninnovativemethodofassessingthemechanicalaxisdeviationinthelowerlimbinstandingposition
AT rajashekardanda aninnovativemethodofassessingthemechanicalaxisdeviationinthelowerlimbinstandingposition
AT nikiljayasheelan aninnovativemethodofassessingthemechanicalaxisdeviationinthelowerlimbinstandingposition
AT rohitsingh aninnovativemethodofassessingthemechanicalaxisdeviationinthelowerlimbinstandingposition
AT jagannathkamath innovativemethodofassessingthemechanicalaxisdeviationinthelowerlimbinstandingposition
AT rajashekardanda innovativemethodofassessingthemechanicalaxisdeviationinthelowerlimbinstandingposition
AT nikiljayasheelan innovativemethodofassessingthemechanicalaxisdeviationinthelowerlimbinstandingposition
AT rohitsingh innovativemethodofassessingthemechanicalaxisdeviationinthelowerlimbinstandingposition
_version_ 1724597249389887488