Comprehensive Evaluation of Anterior Corneal Change in Asphericity Calculated by the Tangential Radius of Curvature after LASIK

To evaluate the change in the anterior corneal asphericity (ΔQ) comprehensively calculated using the tangential radius (rt) after LASIK. Forty-two right eyes were evaluated using the Orbscan II corneal topographer. The pre- and postoperative Q-values of the flat principal semimeridians calculated by...

Full description

Bibliographic Details
Main Authors: Jinglu Ying, Jianqiu Cai, Leru Zhu, Yi Zha
Format: Article
Language:English
Published: Hindawi Limited 2017-01-01
Series:Journal of Ophthalmology
Online Access:http://dx.doi.org/10.1155/2017/3874371
id doaj-d60143bafae440e698c0c6187f49fdc8
record_format Article
spelling doaj-d60143bafae440e698c0c6187f49fdc82020-11-24T21:15:39ZengHindawi LimitedJournal of Ophthalmology2090-004X2090-00582017-01-01201710.1155/2017/38743713874371Comprehensive Evaluation of Anterior Corneal Change in Asphericity Calculated by the Tangential Radius of Curvature after LASIKJinglu Ying0Jianqiu Cai1Leru Zhu2Yi Zha3Department of Ophthalmology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, 3 East Qingchun Road, Hangzhou 310016, ChinaDepartment of Ophthalmology, The Second Affiliated Hospital and Yuying Children’s Hospital of Wenzhou Medical University, No. 109, West-Xueyuan Road, Wenzhou 325027, ChinaDepartment of Ophthalmology, The First Affiliated Hospital of Wenzhou Medical University, No. 2, Fuxue Lane, Wenzhou 325000, ChinaDepartment of Ophthalmology, The Second Affiliated Hospital and Yuying Children’s Hospital of Wenzhou Medical University, No. 109, West-Xueyuan Road, Wenzhou 325027, ChinaTo evaluate the change in the anterior corneal asphericity (ΔQ) comprehensively calculated using the tangential radius (rt) after LASIK. Forty-two right eyes were evaluated using the Orbscan II corneal topographer. The pre- and postoperative Q-values of the flat principal semimeridians calculated by the sagittal radius were compared to those by the tangential radius. The Q-value of each semimeridian in the horizontal region was calculated by rt. Fourier fitting was used to model the 360-semimeridional variation of Q-values and to fit the Q-values in the vertical region before and after surgery. There were significant differences in Q-values between the two methods before (P<0.001) and after surgery (P=0.003). A significant increase in postoperative Q-value was detected compared to preoperative Q-value (P<0.001) calculated by rt. The 360-semimeridional variation of the Q-values was well fitted with a third- and fourth-degree Fourier function before and after surgery. The ΔQ-value distribution presented double valley variation, with the amount of ΔQ being lowest in the near-vertical regions and highest in the near-horizontal regions. Calculating the Q-value with rt combined with Fourier fitting, we evaluated 360 ΔQ-values’ variation of semimeridians of the entire anterior corneal surface and then displayed true and complete anterior corneal shape after LASIK.http://dx.doi.org/10.1155/2017/3874371
collection DOAJ
language English
format Article
sources DOAJ
author Jinglu Ying
Jianqiu Cai
Leru Zhu
Yi Zha
spellingShingle Jinglu Ying
Jianqiu Cai
Leru Zhu
Yi Zha
Comprehensive Evaluation of Anterior Corneal Change in Asphericity Calculated by the Tangential Radius of Curvature after LASIK
Journal of Ophthalmology
author_facet Jinglu Ying
Jianqiu Cai
Leru Zhu
Yi Zha
author_sort Jinglu Ying
title Comprehensive Evaluation of Anterior Corneal Change in Asphericity Calculated by the Tangential Radius of Curvature after LASIK
title_short Comprehensive Evaluation of Anterior Corneal Change in Asphericity Calculated by the Tangential Radius of Curvature after LASIK
title_full Comprehensive Evaluation of Anterior Corneal Change in Asphericity Calculated by the Tangential Radius of Curvature after LASIK
title_fullStr Comprehensive Evaluation of Anterior Corneal Change in Asphericity Calculated by the Tangential Radius of Curvature after LASIK
title_full_unstemmed Comprehensive Evaluation of Anterior Corneal Change in Asphericity Calculated by the Tangential Radius of Curvature after LASIK
title_sort comprehensive evaluation of anterior corneal change in asphericity calculated by the tangential radius of curvature after lasik
publisher Hindawi Limited
series Journal of Ophthalmology
issn 2090-004X
2090-0058
publishDate 2017-01-01
description To evaluate the change in the anterior corneal asphericity (ΔQ) comprehensively calculated using the tangential radius (rt) after LASIK. Forty-two right eyes were evaluated using the Orbscan II corneal topographer. The pre- and postoperative Q-values of the flat principal semimeridians calculated by the sagittal radius were compared to those by the tangential radius. The Q-value of each semimeridian in the horizontal region was calculated by rt. Fourier fitting was used to model the 360-semimeridional variation of Q-values and to fit the Q-values in the vertical region before and after surgery. There were significant differences in Q-values between the two methods before (P<0.001) and after surgery (P=0.003). A significant increase in postoperative Q-value was detected compared to preoperative Q-value (P<0.001) calculated by rt. The 360-semimeridional variation of the Q-values was well fitted with a third- and fourth-degree Fourier function before and after surgery. The ΔQ-value distribution presented double valley variation, with the amount of ΔQ being lowest in the near-vertical regions and highest in the near-horizontal regions. Calculating the Q-value with rt combined with Fourier fitting, we evaluated 360 ΔQ-values’ variation of semimeridians of the entire anterior corneal surface and then displayed true and complete anterior corneal shape after LASIK.
url http://dx.doi.org/10.1155/2017/3874371
work_keys_str_mv AT jingluying comprehensiveevaluationofanteriorcornealchangeinasphericitycalculatedbythetangentialradiusofcurvatureafterlasik
AT jianqiucai comprehensiveevaluationofanteriorcornealchangeinasphericitycalculatedbythetangentialradiusofcurvatureafterlasik
AT leruzhu comprehensiveevaluationofanteriorcornealchangeinasphericitycalculatedbythetangentialradiusofcurvatureafterlasik
AT yizha comprehensiveevaluationofanteriorcornealchangeinasphericitycalculatedbythetangentialradiusofcurvatureafterlasik
_version_ 1716744494997569536