Comprehensive Evaluation of Anterior Corneal Change in Asphericity Calculated by the Tangential Radius of Curvature after LASIK
To evaluate the change in the anterior corneal asphericity (ΔQ) comprehensively calculated using the tangential radius (rt) after LASIK. Forty-two right eyes were evaluated using the Orbscan II corneal topographer. The pre- and postoperative Q-values of the flat principal semimeridians calculated by...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2017-01-01
|
Series: | Journal of Ophthalmology |
Online Access: | http://dx.doi.org/10.1155/2017/3874371 |
id |
doaj-d60143bafae440e698c0c6187f49fdc8 |
---|---|
record_format |
Article |
spelling |
doaj-d60143bafae440e698c0c6187f49fdc82020-11-24T21:15:39ZengHindawi LimitedJournal of Ophthalmology2090-004X2090-00582017-01-01201710.1155/2017/38743713874371Comprehensive Evaluation of Anterior Corneal Change in Asphericity Calculated by the Tangential Radius of Curvature after LASIKJinglu Ying0Jianqiu Cai1Leru Zhu2Yi Zha3Department of Ophthalmology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, 3 East Qingchun Road, Hangzhou 310016, ChinaDepartment of Ophthalmology, The Second Affiliated Hospital and Yuying Children’s Hospital of Wenzhou Medical University, No. 109, West-Xueyuan Road, Wenzhou 325027, ChinaDepartment of Ophthalmology, The First Affiliated Hospital of Wenzhou Medical University, No. 2, Fuxue Lane, Wenzhou 325000, ChinaDepartment of Ophthalmology, The Second Affiliated Hospital and Yuying Children’s Hospital of Wenzhou Medical University, No. 109, West-Xueyuan Road, Wenzhou 325027, ChinaTo evaluate the change in the anterior corneal asphericity (ΔQ) comprehensively calculated using the tangential radius (rt) after LASIK. Forty-two right eyes were evaluated using the Orbscan II corneal topographer. The pre- and postoperative Q-values of the flat principal semimeridians calculated by the sagittal radius were compared to those by the tangential radius. The Q-value of each semimeridian in the horizontal region was calculated by rt. Fourier fitting was used to model the 360-semimeridional variation of Q-values and to fit the Q-values in the vertical region before and after surgery. There were significant differences in Q-values between the two methods before (P<0.001) and after surgery (P=0.003). A significant increase in postoperative Q-value was detected compared to preoperative Q-value (P<0.001) calculated by rt. The 360-semimeridional variation of the Q-values was well fitted with a third- and fourth-degree Fourier function before and after surgery. The ΔQ-value distribution presented double valley variation, with the amount of ΔQ being lowest in the near-vertical regions and highest in the near-horizontal regions. Calculating the Q-value with rt combined with Fourier fitting, we evaluated 360 ΔQ-values’ variation of semimeridians of the entire anterior corneal surface and then displayed true and complete anterior corneal shape after LASIK.http://dx.doi.org/10.1155/2017/3874371 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Jinglu Ying Jianqiu Cai Leru Zhu Yi Zha |
spellingShingle |
Jinglu Ying Jianqiu Cai Leru Zhu Yi Zha Comprehensive Evaluation of Anterior Corneal Change in Asphericity Calculated by the Tangential Radius of Curvature after LASIK Journal of Ophthalmology |
author_facet |
Jinglu Ying Jianqiu Cai Leru Zhu Yi Zha |
author_sort |
Jinglu Ying |
title |
Comprehensive Evaluation of Anterior Corneal Change in Asphericity Calculated by the Tangential Radius of Curvature after LASIK |
title_short |
Comprehensive Evaluation of Anterior Corneal Change in Asphericity Calculated by the Tangential Radius of Curvature after LASIK |
title_full |
Comprehensive Evaluation of Anterior Corneal Change in Asphericity Calculated by the Tangential Radius of Curvature after LASIK |
title_fullStr |
Comprehensive Evaluation of Anterior Corneal Change in Asphericity Calculated by the Tangential Radius of Curvature after LASIK |
title_full_unstemmed |
Comprehensive Evaluation of Anterior Corneal Change in Asphericity Calculated by the Tangential Radius of Curvature after LASIK |
title_sort |
comprehensive evaluation of anterior corneal change in asphericity calculated by the tangential radius of curvature after lasik |
publisher |
Hindawi Limited |
series |
Journal of Ophthalmology |
issn |
2090-004X 2090-0058 |
publishDate |
2017-01-01 |
description |
To evaluate the change in the anterior corneal asphericity (ΔQ) comprehensively calculated using the tangential radius (rt) after LASIK. Forty-two right eyes were evaluated using the Orbscan II corneal topographer. The pre- and postoperative Q-values of the flat principal semimeridians calculated by the sagittal radius were compared to those by the tangential radius. The Q-value of each semimeridian in the horizontal region was calculated by rt. Fourier fitting was used to model the 360-semimeridional variation of Q-values and to fit the Q-values in the vertical region before and after surgery. There were significant differences in Q-values between the two methods before (P<0.001) and after surgery (P=0.003). A significant increase in postoperative Q-value was detected compared to preoperative Q-value (P<0.001) calculated by rt. The 360-semimeridional variation of the Q-values was well fitted with a third- and fourth-degree Fourier function before and after surgery. The ΔQ-value distribution presented double valley variation, with the amount of ΔQ being lowest in the near-vertical regions and highest in the near-horizontal regions. Calculating the Q-value with rt combined with Fourier fitting, we evaluated 360 ΔQ-values’ variation of semimeridians of the entire anterior corneal surface and then displayed true and complete anterior corneal shape after LASIK. |
url |
http://dx.doi.org/10.1155/2017/3874371 |
work_keys_str_mv |
AT jingluying comprehensiveevaluationofanteriorcornealchangeinasphericitycalculatedbythetangentialradiusofcurvatureafterlasik AT jianqiucai comprehensiveevaluationofanteriorcornealchangeinasphericitycalculatedbythetangentialradiusofcurvatureafterlasik AT leruzhu comprehensiveevaluationofanteriorcornealchangeinasphericitycalculatedbythetangentialradiusofcurvatureafterlasik AT yizha comprehensiveevaluationofanteriorcornealchangeinasphericitycalculatedbythetangentialradiusofcurvatureafterlasik |
_version_ |
1716744494997569536 |