Feasibility of telecytopathology for rapid preliminary diagnosis of ultrasound-guided fine needle aspiration of axillary lymph nodes in a remote breast care center

Background: In the recent years, the advances in digital methods in pathology have resulted in the use of telecytology in the immediate assessment of fine needle aspiration (FNA) specimens. However, there is a need for organ-based and body site-specific studies on the use of telecytology for the imm...

Full description

Bibliographic Details
Main Authors: Kamal K Khurana, Andra Kovalovsky, Deepa Masrani
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2012-01-01
Series:Journal of Pathology Informatics
Subjects:
FNA
Online Access:http://www.jpathinformatics.org/article.asp?issn=2153-3539;year=2012;volume=3;issue=1;spage=36;epage=36;aulast=
id doaj-d5c1b1bca35f487696f1455cc68349a4
record_format Article
spelling doaj-d5c1b1bca35f487696f1455cc68349a42020-11-24T23:08:36ZengWolters Kluwer Medknow PublicationsJournal of Pathology Informatics2153-35392153-35392012-01-0131363610.4103/2153-3539.101803Feasibility of telecytopathology for rapid preliminary diagnosis of ultrasound-guided fine needle aspiration of axillary lymph nodes in a remote breast care centerKamal K KhuranaAndra KovalovskyDeepa MasraniBackground: In the recent years, the advances in digital methods in pathology have resulted in the use of telecytology in the immediate assessment of fine needle aspiration (FNA) specimens. However, there is a need for organ-based and body site-specific studies on the use of telecytology for the immediate assessment of FNA to evaluate its pitfalls and limitations. We present our experience with the use of telecytology for on-site evaluation of ultrasound-guided FNA (USG-FNA) of axillary lymph nodes in a remote breast care center. Materials and Methods: Real-time images of Diff-Quik-stained cytology smears were obtained with an Olympus digital camera attached to an Olympus CX41 microscope and transmitted via ethernet by a cytotechnologist to a pathologist who rendered preliminary diagnosis while communicating with the on-site cytotechnologist over the Vocera system. The accuracy of the preliminary diagnosis was compared with the final diagnosis, retrospectively. Results: A total of 39 female patients (mean age: 50.5 years) seen at the breast care center underwent USG-FNA of 44 axillary nodes. Preliminary diagnoses of benign, suspicious/malignant, and unsatisfactory were 41, 52, and 7%, respectively. Only one of the 23 cases that were initially interpreted as benign was reclassified as suspicious on final cytologic diagnosis. Seventeen of 18 suspicious/malignant cases on initial cytology corresponded with a malignant diagnosis on final cytology. One suspicious case was reclassified as benign on final cytologic diagnosis. All unsatisfactory cases remained inadequate for final cytologic interpretation. The presence of additional material in the cell block and interpretative error were the main reasons for discrepancy, accounting for the two discrepant cases. Conclusions: This retrospective study demonstrates that the on-site telecytology evaluation of USG-FNA of axillary lymph nodes in patients at a remote breast care center was highly accurate compared with the final cytologic evaluation. It allows pathologists to use their time more efficiently and makes on-site evaluation at a remote site possible.http://www.jpathinformatics.org/article.asp?issn=2153-3539;year=2012;volume=3;issue=1;spage=36;epage=36;aulast=Axillary lymph nodesFNAtelecytopathologyultrasound-guided FNA
collection DOAJ
language English
format Article
sources DOAJ
author Kamal K Khurana
Andra Kovalovsky
Deepa Masrani
spellingShingle Kamal K Khurana
Andra Kovalovsky
Deepa Masrani
Feasibility of telecytopathology for rapid preliminary diagnosis of ultrasound-guided fine needle aspiration of axillary lymph nodes in a remote breast care center
Journal of Pathology Informatics
Axillary lymph nodes
FNA
telecytopathology
ultrasound-guided FNA
author_facet Kamal K Khurana
Andra Kovalovsky
Deepa Masrani
author_sort Kamal K Khurana
title Feasibility of telecytopathology for rapid preliminary diagnosis of ultrasound-guided fine needle aspiration of axillary lymph nodes in a remote breast care center
title_short Feasibility of telecytopathology for rapid preliminary diagnosis of ultrasound-guided fine needle aspiration of axillary lymph nodes in a remote breast care center
title_full Feasibility of telecytopathology for rapid preliminary diagnosis of ultrasound-guided fine needle aspiration of axillary lymph nodes in a remote breast care center
title_fullStr Feasibility of telecytopathology for rapid preliminary diagnosis of ultrasound-guided fine needle aspiration of axillary lymph nodes in a remote breast care center
title_full_unstemmed Feasibility of telecytopathology for rapid preliminary diagnosis of ultrasound-guided fine needle aspiration of axillary lymph nodes in a remote breast care center
title_sort feasibility of telecytopathology for rapid preliminary diagnosis of ultrasound-guided fine needle aspiration of axillary lymph nodes in a remote breast care center
publisher Wolters Kluwer Medknow Publications
series Journal of Pathology Informatics
issn 2153-3539
2153-3539
publishDate 2012-01-01
description Background: In the recent years, the advances in digital methods in pathology have resulted in the use of telecytology in the immediate assessment of fine needle aspiration (FNA) specimens. However, there is a need for organ-based and body site-specific studies on the use of telecytology for the immediate assessment of FNA to evaluate its pitfalls and limitations. We present our experience with the use of telecytology for on-site evaluation of ultrasound-guided FNA (USG-FNA) of axillary lymph nodes in a remote breast care center. Materials and Methods: Real-time images of Diff-Quik-stained cytology smears were obtained with an Olympus digital camera attached to an Olympus CX41 microscope and transmitted via ethernet by a cytotechnologist to a pathologist who rendered preliminary diagnosis while communicating with the on-site cytotechnologist over the Vocera system. The accuracy of the preliminary diagnosis was compared with the final diagnosis, retrospectively. Results: A total of 39 female patients (mean age: 50.5 years) seen at the breast care center underwent USG-FNA of 44 axillary nodes. Preliminary diagnoses of benign, suspicious/malignant, and unsatisfactory were 41, 52, and 7%, respectively. Only one of the 23 cases that were initially interpreted as benign was reclassified as suspicious on final cytologic diagnosis. Seventeen of 18 suspicious/malignant cases on initial cytology corresponded with a malignant diagnosis on final cytology. One suspicious case was reclassified as benign on final cytologic diagnosis. All unsatisfactory cases remained inadequate for final cytologic interpretation. The presence of additional material in the cell block and interpretative error were the main reasons for discrepancy, accounting for the two discrepant cases. Conclusions: This retrospective study demonstrates that the on-site telecytology evaluation of USG-FNA of axillary lymph nodes in patients at a remote breast care center was highly accurate compared with the final cytologic evaluation. It allows pathologists to use their time more efficiently and makes on-site evaluation at a remote site possible.
topic Axillary lymph nodes
FNA
telecytopathology
ultrasound-guided FNA
url http://www.jpathinformatics.org/article.asp?issn=2153-3539;year=2012;volume=3;issue=1;spage=36;epage=36;aulast=
work_keys_str_mv AT kamalkkhurana feasibilityoftelecytopathologyforrapidpreliminarydiagnosisofultrasoundguidedfineneedleaspirationofaxillarylymphnodesinaremotebreastcarecenter
AT andrakovalovsky feasibilityoftelecytopathologyforrapidpreliminarydiagnosisofultrasoundguidedfineneedleaspirationofaxillarylymphnodesinaremotebreastcarecenter
AT deepamasrani feasibilityoftelecytopathologyforrapidpreliminarydiagnosisofultrasoundguidedfineneedleaspirationofaxillarylymphnodesinaremotebreastcarecenter
_version_ 1725613424891658240