Positioning and control of scanning electrochemical microscopy / Skenuojančiojo elektrocheminio mikroskopo pozicionavimas ir valdymas

Positioning problems of scanning electrochemical microscopy (SECM) are very important by means of living cells damaging by moving ultramicroelectrode (UME). The working principle and operating modes of SECM are introduced. Investigation of redox activity of living cells are outlined. Problems, whic...

Full description

Bibliographic Details
Main Authors: Inga Morkvėnaitė-Vilkončienė, Sigitas Petkevičius, Gabrielė Keraitė, Paulius Šakalys, Tadas Lenkutis
Format: Article
Language:English
Published: Vilnius Gediminas Technical University 2018-01-01
Series:Mokslas: Lietuvos Ateitis
Subjects:
Online Access:http://journals.vgtu.lt/index.php/MLA/article/view/118
id doaj-d58552b01d374bce9706293efbbc98c7
record_format Article
spelling doaj-d58552b01d374bce9706293efbbc98c72021-05-02T09:45:23ZengVilnius Gediminas Technical UniversityMokslas: Lietuvos Ateitis2029-23412029-22522018-01-019610.3846/mla.2017.1093Positioning and control of scanning electrochemical microscopy / Skenuojančiojo elektrocheminio mikroskopo pozicionavimas ir valdymasInga Morkvėnaitė-Vilkončienė0Sigitas Petkevičius1Gabrielė Keraitė2Paulius Šakalys3Tadas Lenkutis4Vilnius Gediminas Technical University, Vilnius, LithuaniaVilnius Gediminas Technical University, Vilnius, LithuaniaVilnius Gediminas Technical University, Vilnius, LithuaniaVilnius Gediminas Technical University, Vilnius, LithuaniaVilnius Gediminas Technical University, Vilnius, Lithuania Positioning problems of scanning electrochemical microscopy (SECM) are very important by means of living cells damaging by moving ultramicroelectrode (UME). The working principle and operating modes of SECM are introduced. Investigation of redox activity of living cells are outlined. Problems, which arise in investigations of living cells by constant distance and constant height modes are discussed. Technical challenges and advances in application of SECM in living cell investigations are provided. Santrauka Tinkamas skenuojančiojo elektrocheminio mikroskopo (SECM) ultramikroelektrodo (UME) pozicionavimas yra aktualus eksperimentuojant su gyvomis ląstelėmis, nes gali pažeisti ląstelių paviršių. Šiame straipsnyje pateikiami SECM veikimo principas ir darbo režimai. Nagrinėjamas gyvų ląstelių oksidavimo ir redukavimo aktyvumas. Straipnyje pateikiama problemų, kurių kyla matuojant pastovaus aukščio ir pastovaus atstumo metodais, analizė. Pateikiami techniniai pozicionavimo sprendimai, iššūkiai ir progresas, taikant matuoti SECM gyvoms ląstelėms. Reikšminiai žodžiai: skenuojantysis elektrocheminis mikroskopas, gyvos ląstelės, ultramikroelektrodas, žmogaus ląstelės, priartėjimo kreivės, šlyties jėgos SECM. http://journals.vgtu.lt/index.php/MLA/article/view/118scanning electrochemical microscopyliving cellsultramicroelectrodehuman cellsapproaching curvesshear- force SECM
collection DOAJ
language English
format Article
sources DOAJ
author Inga Morkvėnaitė-Vilkončienė
Sigitas Petkevičius
Gabrielė Keraitė
Paulius Šakalys
Tadas Lenkutis
spellingShingle Inga Morkvėnaitė-Vilkončienė
Sigitas Petkevičius
Gabrielė Keraitė
Paulius Šakalys
Tadas Lenkutis
Positioning and control of scanning electrochemical microscopy / Skenuojančiojo elektrocheminio mikroskopo pozicionavimas ir valdymas
Mokslas: Lietuvos Ateitis
scanning electrochemical microscopy
living cells
ultramicroelectrode
human cells
approaching curves
shear- force SECM
author_facet Inga Morkvėnaitė-Vilkončienė
Sigitas Petkevičius
Gabrielė Keraitė
Paulius Šakalys
Tadas Lenkutis
author_sort Inga Morkvėnaitė-Vilkončienė
title Positioning and control of scanning electrochemical microscopy / Skenuojančiojo elektrocheminio mikroskopo pozicionavimas ir valdymas
title_short Positioning and control of scanning electrochemical microscopy / Skenuojančiojo elektrocheminio mikroskopo pozicionavimas ir valdymas
title_full Positioning and control of scanning electrochemical microscopy / Skenuojančiojo elektrocheminio mikroskopo pozicionavimas ir valdymas
title_fullStr Positioning and control of scanning electrochemical microscopy / Skenuojančiojo elektrocheminio mikroskopo pozicionavimas ir valdymas
title_full_unstemmed Positioning and control of scanning electrochemical microscopy / Skenuojančiojo elektrocheminio mikroskopo pozicionavimas ir valdymas
title_sort positioning and control of scanning electrochemical microscopy / skenuojančiojo elektrocheminio mikroskopo pozicionavimas ir valdymas
publisher Vilnius Gediminas Technical University
series Mokslas: Lietuvos Ateitis
issn 2029-2341
2029-2252
publishDate 2018-01-01
description Positioning problems of scanning electrochemical microscopy (SECM) are very important by means of living cells damaging by moving ultramicroelectrode (UME). The working principle and operating modes of SECM are introduced. Investigation of redox activity of living cells are outlined. Problems, which arise in investigations of living cells by constant distance and constant height modes are discussed. Technical challenges and advances in application of SECM in living cell investigations are provided. Santrauka Tinkamas skenuojančiojo elektrocheminio mikroskopo (SECM) ultramikroelektrodo (UME) pozicionavimas yra aktualus eksperimentuojant su gyvomis ląstelėmis, nes gali pažeisti ląstelių paviršių. Šiame straipsnyje pateikiami SECM veikimo principas ir darbo režimai. Nagrinėjamas gyvų ląstelių oksidavimo ir redukavimo aktyvumas. Straipnyje pateikiama problemų, kurių kyla matuojant pastovaus aukščio ir pastovaus atstumo metodais, analizė. Pateikiami techniniai pozicionavimo sprendimai, iššūkiai ir progresas, taikant matuoti SECM gyvoms ląstelėms. Reikšminiai žodžiai: skenuojantysis elektrocheminis mikroskopas, gyvos ląstelės, ultramikroelektrodas, žmogaus ląstelės, priartėjimo kreivės, šlyties jėgos SECM.
topic scanning electrochemical microscopy
living cells
ultramicroelectrode
human cells
approaching curves
shear- force SECM
url http://journals.vgtu.lt/index.php/MLA/article/view/118
work_keys_str_mv AT ingamorkvenaitevilkonciene positioningandcontrolofscanningelectrochemicalmicroscopyskenuojanciojoelektrocheminiomikroskopopozicionavimasirvaldymas
AT sigitaspetkevicius positioningandcontrolofscanningelectrochemicalmicroscopyskenuojanciojoelektrocheminiomikroskopopozicionavimasirvaldymas
AT gabrielekeraite positioningandcontrolofscanningelectrochemicalmicroscopyskenuojanciojoelektrocheminiomikroskopopozicionavimasirvaldymas
AT pauliussakalys positioningandcontrolofscanningelectrochemicalmicroscopyskenuojanciojoelektrocheminiomikroskopopozicionavimasirvaldymas
AT tadaslenkutis positioningandcontrolofscanningelectrochemicalmicroscopyskenuojanciojoelektrocheminiomikroskopopozicionavimasirvaldymas
_version_ 1721493239765139456