Experimental Study on The Replacement of HFC-R134A by Hydrocarbons Mixture in Automotive Air Conditioner
Performance characteristics of the current automotive air conditioning system have been evaluated in this experimental study which will evaluate the power consumption, cabin temperature and coefficient of performance (COP) at various internal heat loads and engine speeds using hydro-chlorofl...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universitas Indonesia
2014-01-01
|
Series: | International Journal of Technology |
Subjects: | |
Online Access: | http://ijtech.eng.ui.ac.id/article/view/1188 |
id |
doaj-d5699c04e6bb43ec8460a41d9dbdeb7a |
---|---|
record_format |
Article |
spelling |
doaj-d5699c04e6bb43ec8460a41d9dbdeb7a2020-11-25T02:03:26ZengUniversitas IndonesiaInternational Journal of Technology2086-96142087-21002014-01-0141819210.14716/ijtech.v4i1.11881188Experimental Study on The Replacement of HFC-R134A by Hydrocarbons Mixture in Automotive Air ConditionerMohd Rozi Mohd Perang0Henry Nasution1Zulkarnain Abdul Latiff2Azhar Abdul Aziz3Afiq Aiman Dahlan4Automotive Development Centre, Universiti Teknologi Malaysia Skudai, Johor, Malaysia 81310Automotive Development Centre, Universiti Teknologi Malaysia Skudai, Johor, Malaysia 81310 ; Faculty of Mechanical Engineering, Universiti Teknologi Malaysia Skudai, Johor, Malaysia 81310Automotive Development Centre, Universiti Teknologi Malaysia Skudai, Johor, Malaysia 81310 2 Faculty of Mechanical Engineering, Universiti Teknologi Malaysia Skudai, Johor, Malaysia 81310Automotive Development Centre, Universiti Teknologi Malaysia Skudai, Johor, Malaysia 81310 2 Faculty of Mechanical Engineering, Universiti Teknologi Malaysia Skudai, Johor, Malaysia 81310Faculty of Mechanical Engineering, Universiti Teknologi Malaysia Skudai, Johor, Malaysia 81310Performance characteristics of the current automotive air conditioning system have been evaluated in this experimental study which will evaluate the power consumption, cabin temperature and coefficient of performance (COP) at various internal heat loads and engine speeds using hydro-chlorofluorocarbons refrigerant (HFC-R134a) and automotive hydrocarbon mixture refrigerant (AHCR) as the working fluid of the compressor. Both refrigerants will be tested on the experimental rig which simulated the actual cars as an internal cabin complete with a cooling system component of the actual car including the blower, evaporator, condenser, radiator, electric motor, compressor and alternator. The electric motor acts as a vehicle engine, and then it will drive the compressor using a belt and pulley system, as well as being connected to the alternator to recharge the battery. The rig also is equipped with a simulation room acting as the passenger compartment. The tests have been performed by varying the motor speed; 1000, 1500, 2000, 2500 and 3000 rpm, temperature set-point; 21, 22 and 230C, and internal heat loads; 0, 500, 700 and 1000 W. As for the results, the performance characteristics of the AHCR indicate the positive improvement of the system compared to HFC-R134a.http://ijtech.eng.ui.ac.id/article/view/1188Air conditioning, Automotive, Energy saving, HCR-134a, Performance |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Mohd Rozi Mohd Perang Henry Nasution Zulkarnain Abdul Latiff Azhar Abdul Aziz Afiq Aiman Dahlan |
spellingShingle |
Mohd Rozi Mohd Perang Henry Nasution Zulkarnain Abdul Latiff Azhar Abdul Aziz Afiq Aiman Dahlan Experimental Study on The Replacement of HFC-R134A by Hydrocarbons Mixture in Automotive Air Conditioner International Journal of Technology Air conditioning, Automotive, Energy saving, HCR-134a, Performance |
author_facet |
Mohd Rozi Mohd Perang Henry Nasution Zulkarnain Abdul Latiff Azhar Abdul Aziz Afiq Aiman Dahlan |
author_sort |
Mohd Rozi Mohd Perang |
title |
Experimental Study on The Replacement of HFC-R134A by Hydrocarbons Mixture in Automotive Air Conditioner |
title_short |
Experimental Study on The Replacement of HFC-R134A by Hydrocarbons Mixture in Automotive Air Conditioner |
title_full |
Experimental Study on The Replacement of HFC-R134A by Hydrocarbons Mixture in Automotive Air Conditioner |
title_fullStr |
Experimental Study on The Replacement of HFC-R134A by Hydrocarbons Mixture in Automotive Air Conditioner |
title_full_unstemmed |
Experimental Study on The Replacement of HFC-R134A by Hydrocarbons Mixture in Automotive Air Conditioner |
title_sort |
experimental study on the replacement of hfc-r134a by hydrocarbons mixture in automotive air conditioner |
publisher |
Universitas Indonesia |
series |
International Journal of Technology |
issn |
2086-9614 2087-2100 |
publishDate |
2014-01-01 |
description |
Performance characteristics of the current automotive air conditioning
system have been evaluated in this experimental study which will
evaluate the power consumption, cabin temperature and coefficient of
performance (COP) at various internal heat loads and engine speeds using
hydro-chlorofluorocarbons refrigerant (HFC-R134a) and automotive
hydrocarbon mixture refrigerant (AHCR) as the working fluid of the
compressor. Both refrigerants will be tested on the experimental rig
which simulated the actual cars as an internal cabin complete with a
cooling system component of the actual car including the blower,
evaporator, condenser, radiator, electric motor, compressor and
alternator. The electric motor acts as a vehicle engine, and then it
will drive the compressor using a belt and pulley system, as well as
being connected to the alternator to recharge the battery. The rig also
is equipped with a simulation room acting as the passenger compartment.
The tests have been performed by varying the motor speed; 1000, 1500,
2000, 2500 and 3000 rpm, temperature set-point; 21, 22 and 230C, and
internal heat loads; 0, 500, 700 and 1000 W. As for the results, the
performance characteristics of the AHCR indicate the positive
improvement of the system compared to HFC-R134a. |
topic |
Air conditioning, Automotive, Energy saving, HCR-134a, Performance |
url |
http://ijtech.eng.ui.ac.id/article/view/1188 |
work_keys_str_mv |
AT mohdrozimohdperang experimentalstudyonthereplacementofhfcr134abyhydrocarbonsmixtureinautomotiveairconditioner AT henrynasution experimentalstudyonthereplacementofhfcr134abyhydrocarbonsmixtureinautomotiveairconditioner AT zulkarnainabdullatiff experimentalstudyonthereplacementofhfcr134abyhydrocarbonsmixtureinautomotiveairconditioner AT azharabdulaziz experimentalstudyonthereplacementofhfcr134abyhydrocarbonsmixtureinautomotiveairconditioner AT afiqaimandahlan experimentalstudyonthereplacementofhfcr134abyhydrocarbonsmixtureinautomotiveairconditioner |
_version_ |
1724948303732277248 |