High resolution phase space measurements with Allison-type emittance scanners

Allison-type emittance scanners are widely used to measure projected 2D phase space distributions of low energy beams. This paper extends the conventional data analysis model to introduce three significant corrections that commonly arise in the pursuit of high resolution measurements. First, effecti...

Full description

Bibliographic Details
Main Authors: Jonathan C. Wong, Steven M. Lund, Tomofumi Maruta
Format: Article
Language:English
Published: American Physical Society 2019-07-01
Series:Physical Review Accelerators and Beams
Online Access:http://doi.org/10.1103/PhysRevAccelBeams.22.072801
id doaj-d4ce28f684784f5aa9f711d942579e6f
record_format Article
spelling doaj-d4ce28f684784f5aa9f711d942579e6f2020-11-25T01:56:42ZengAmerican Physical SocietyPhysical Review Accelerators and Beams2469-98882019-07-0122707280110.1103/PhysRevAccelBeams.22.072801High resolution phase space measurements with Allison-type emittance scannersJonathan C. WongSteven M. LundTomofumi MarutaAllison-type emittance scanners are widely used to measure projected 2D phase space distributions of low energy beams. This paper extends the conventional data analysis model to introduce three significant corrections that commonly arise in the pursuit of high resolution measurements. First, effective longitudinal asymmetry in the E-dipole placement (typically resulting from directional choice of relief cuts in thick slit-plates) causes deviation from the ideal voltage-to-angle conversion relation. Second, finite slit thickness generates variation in weights of data points that should be compensated. Third, when the interval between data points is smaller than the device resolution (ordinary in the angular data accumulation), a detailed account of the phase space region contributing to each data point can be used to resolve the beam distribution more accurately. These findings are illustrated by simulations with numerically generated phase space distributions. The improved model is applied to experimental measurements of an Ar ion beam with an Allison scanner operating at the front-end of the Facility for Rare Isotope Beams (FRIB) at Michigan State University. Results show that the improved model obtains better agreement among a set of measurements and modifies beam moments significantly (can be ∼10% relative to conventional methods, with larger deviations at increasing angular divergence), thus rendering the corrections important for accurate high resolution phase-space characterizations. Python code tools that implement the improved analysis described are made available. These tools are readily applicable to any Allison scanner given a specification of the device geometry and scan ranges associated with each measurement.http://doi.org/10.1103/PhysRevAccelBeams.22.072801
collection DOAJ
language English
format Article
sources DOAJ
author Jonathan C. Wong
Steven M. Lund
Tomofumi Maruta
spellingShingle Jonathan C. Wong
Steven M. Lund
Tomofumi Maruta
High resolution phase space measurements with Allison-type emittance scanners
Physical Review Accelerators and Beams
author_facet Jonathan C. Wong
Steven M. Lund
Tomofumi Maruta
author_sort Jonathan C. Wong
title High resolution phase space measurements with Allison-type emittance scanners
title_short High resolution phase space measurements with Allison-type emittance scanners
title_full High resolution phase space measurements with Allison-type emittance scanners
title_fullStr High resolution phase space measurements with Allison-type emittance scanners
title_full_unstemmed High resolution phase space measurements with Allison-type emittance scanners
title_sort high resolution phase space measurements with allison-type emittance scanners
publisher American Physical Society
series Physical Review Accelerators and Beams
issn 2469-9888
publishDate 2019-07-01
description Allison-type emittance scanners are widely used to measure projected 2D phase space distributions of low energy beams. This paper extends the conventional data analysis model to introduce three significant corrections that commonly arise in the pursuit of high resolution measurements. First, effective longitudinal asymmetry in the E-dipole placement (typically resulting from directional choice of relief cuts in thick slit-plates) causes deviation from the ideal voltage-to-angle conversion relation. Second, finite slit thickness generates variation in weights of data points that should be compensated. Third, when the interval between data points is smaller than the device resolution (ordinary in the angular data accumulation), a detailed account of the phase space region contributing to each data point can be used to resolve the beam distribution more accurately. These findings are illustrated by simulations with numerically generated phase space distributions. The improved model is applied to experimental measurements of an Ar ion beam with an Allison scanner operating at the front-end of the Facility for Rare Isotope Beams (FRIB) at Michigan State University. Results show that the improved model obtains better agreement among a set of measurements and modifies beam moments significantly (can be ∼10% relative to conventional methods, with larger deviations at increasing angular divergence), thus rendering the corrections important for accurate high resolution phase-space characterizations. Python code tools that implement the improved analysis described are made available. These tools are readily applicable to any Allison scanner given a specification of the device geometry and scan ranges associated with each measurement.
url http://doi.org/10.1103/PhysRevAccelBeams.22.072801
work_keys_str_mv AT jonathancwong highresolutionphasespacemeasurementswithallisontypeemittancescanners
AT stevenmlund highresolutionphasespacemeasurementswithallisontypeemittancescanners
AT tomofumimaruta highresolutionphasespacemeasurementswithallisontypeemittancescanners
_version_ 1724978489497485312