High resolution phase space measurements with Allison-type emittance scanners
Allison-type emittance scanners are widely used to measure projected 2D phase space distributions of low energy beams. This paper extends the conventional data analysis model to introduce three significant corrections that commonly arise in the pursuit of high resolution measurements. First, effecti...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
American Physical Society
2019-07-01
|
Series: | Physical Review Accelerators and Beams |
Online Access: | http://doi.org/10.1103/PhysRevAccelBeams.22.072801 |
id |
doaj-d4ce28f684784f5aa9f711d942579e6f |
---|---|
record_format |
Article |
spelling |
doaj-d4ce28f684784f5aa9f711d942579e6f2020-11-25T01:56:42ZengAmerican Physical SocietyPhysical Review Accelerators and Beams2469-98882019-07-0122707280110.1103/PhysRevAccelBeams.22.072801High resolution phase space measurements with Allison-type emittance scannersJonathan C. WongSteven M. LundTomofumi MarutaAllison-type emittance scanners are widely used to measure projected 2D phase space distributions of low energy beams. This paper extends the conventional data analysis model to introduce three significant corrections that commonly arise in the pursuit of high resolution measurements. First, effective longitudinal asymmetry in the E-dipole placement (typically resulting from directional choice of relief cuts in thick slit-plates) causes deviation from the ideal voltage-to-angle conversion relation. Second, finite slit thickness generates variation in weights of data points that should be compensated. Third, when the interval between data points is smaller than the device resolution (ordinary in the angular data accumulation), a detailed account of the phase space region contributing to each data point can be used to resolve the beam distribution more accurately. These findings are illustrated by simulations with numerically generated phase space distributions. The improved model is applied to experimental measurements of an Ar ion beam with an Allison scanner operating at the front-end of the Facility for Rare Isotope Beams (FRIB) at Michigan State University. Results show that the improved model obtains better agreement among a set of measurements and modifies beam moments significantly (can be ∼10% relative to conventional methods, with larger deviations at increasing angular divergence), thus rendering the corrections important for accurate high resolution phase-space characterizations. Python code tools that implement the improved analysis described are made available. These tools are readily applicable to any Allison scanner given a specification of the device geometry and scan ranges associated with each measurement.http://doi.org/10.1103/PhysRevAccelBeams.22.072801 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Jonathan C. Wong Steven M. Lund Tomofumi Maruta |
spellingShingle |
Jonathan C. Wong Steven M. Lund Tomofumi Maruta High resolution phase space measurements with Allison-type emittance scanners Physical Review Accelerators and Beams |
author_facet |
Jonathan C. Wong Steven M. Lund Tomofumi Maruta |
author_sort |
Jonathan C. Wong |
title |
High resolution phase space measurements with Allison-type emittance scanners |
title_short |
High resolution phase space measurements with Allison-type emittance scanners |
title_full |
High resolution phase space measurements with Allison-type emittance scanners |
title_fullStr |
High resolution phase space measurements with Allison-type emittance scanners |
title_full_unstemmed |
High resolution phase space measurements with Allison-type emittance scanners |
title_sort |
high resolution phase space measurements with allison-type emittance scanners |
publisher |
American Physical Society |
series |
Physical Review Accelerators and Beams |
issn |
2469-9888 |
publishDate |
2019-07-01 |
description |
Allison-type emittance scanners are widely used to measure projected 2D phase space distributions of low energy beams. This paper extends the conventional data analysis model to introduce three significant corrections that commonly arise in the pursuit of high resolution measurements. First, effective longitudinal asymmetry in the E-dipole placement (typically resulting from directional choice of relief cuts in thick slit-plates) causes deviation from the ideal voltage-to-angle conversion relation. Second, finite slit thickness generates variation in weights of data points that should be compensated. Third, when the interval between data points is smaller than the device resolution (ordinary in the angular data accumulation), a detailed account of the phase space region contributing to each data point can be used to resolve the beam distribution more accurately. These findings are illustrated by simulations with numerically generated phase space distributions. The improved model is applied to experimental measurements of an Ar ion beam with an Allison scanner operating at the front-end of the Facility for Rare Isotope Beams (FRIB) at Michigan State University. Results show that the improved model obtains better agreement among a set of measurements and modifies beam moments significantly (can be ∼10% relative to conventional methods, with larger deviations at increasing angular divergence), thus rendering the corrections important for accurate high resolution phase-space characterizations. Python code tools that implement the improved analysis described are made available. These tools are readily applicable to any Allison scanner given a specification of the device geometry and scan ranges associated with each measurement. |
url |
http://doi.org/10.1103/PhysRevAccelBeams.22.072801 |
work_keys_str_mv |
AT jonathancwong highresolutionphasespacemeasurementswithallisontypeemittancescanners AT stevenmlund highresolutionphasespacemeasurementswithallisontypeemittancescanners AT tomofumimaruta highresolutionphasespacemeasurementswithallisontypeemittancescanners |
_version_ |
1724978489497485312 |