Steady-State Thermal Field Analysis from the Turbo-Generator Rotor with Direct Cooling
Our paper presents a combined method for the steady-state thermal field analysis from the turbo-generator rotor with the direct cooling. The thermal field analysis is made in two stages: 1) In the first stage, in order to determine the domain with the highest temperature, the thermal field is simula...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Stefan cel Mare University of Suceava
2007-11-01
|
Series: | Advances in Electrical and Computer Engineering |
Subjects: | |
Online Access: | http://dx.doi.org/10.4316/AECE.2007.02007 |
id |
doaj-d4c533c84ab44b638c63c06f381bfcba |
---|---|
record_format |
Article |
spelling |
doaj-d4c533c84ab44b638c63c06f381bfcba2020-11-24T21:43:09ZengStefan cel Mare University of SuceavaAdvances in Electrical and Computer Engineering1582-74451844-76002007-11-01722832Steady-State Thermal Field Analysis from the Turbo-Generator Rotor with Direct CoolingPETRESCU, C.DUMITRIU, L.VOICU, N.IORDACHE, M.Our paper presents a combined method for the steady-state thermal field analysis from the turbo-generator rotor with the direct cooling. The thermal field analysis is made in two stages: 1) In the first stage, in order to determine the domain with the highest temperature, the thermal field is simulated by the thermal resistances and concentrated losses, 2) In the second stage, using the 3D finite difference method, we determine with a very good accuracy the point with the highest temperature from the rotor.http://dx.doi.org/10.4316/AECE.2007.02007thermal fieldsimulationequivalent circuittemperature |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
PETRESCU, C. DUMITRIU, L. VOICU, N. IORDACHE, M. |
spellingShingle |
PETRESCU, C. DUMITRIU, L. VOICU, N. IORDACHE, M. Steady-State Thermal Field Analysis from the Turbo-Generator Rotor with Direct Cooling Advances in Electrical and Computer Engineering thermal field simulation equivalent circuit temperature |
author_facet |
PETRESCU, C. DUMITRIU, L. VOICU, N. IORDACHE, M. |
author_sort |
PETRESCU, C. |
title |
Steady-State Thermal Field Analysis from the Turbo-Generator Rotor with Direct Cooling |
title_short |
Steady-State Thermal Field Analysis from the Turbo-Generator Rotor with Direct Cooling |
title_full |
Steady-State Thermal Field Analysis from the Turbo-Generator Rotor with Direct Cooling |
title_fullStr |
Steady-State Thermal Field Analysis from the Turbo-Generator Rotor with Direct Cooling |
title_full_unstemmed |
Steady-State Thermal Field Analysis from the Turbo-Generator Rotor with Direct Cooling |
title_sort |
steady-state thermal field analysis from the turbo-generator rotor with direct cooling |
publisher |
Stefan cel Mare University of Suceava |
series |
Advances in Electrical and Computer Engineering |
issn |
1582-7445 1844-7600 |
publishDate |
2007-11-01 |
description |
Our paper presents a combined method for the steady-state thermal field analysis from the turbo-generator rotor with the direct cooling. The thermal field analysis is made in two stages: 1) In the first stage, in order to determine the domain with the highest temperature, the thermal field is simulated by the thermal resistances and concentrated losses, 2) In the second stage, using the 3D finite difference method, we determine with a very good accuracy the point with the highest temperature from the rotor. |
topic |
thermal field simulation equivalent circuit temperature |
url |
http://dx.doi.org/10.4316/AECE.2007.02007 |
work_keys_str_mv |
AT petrescuc steadystatethermalfieldanalysisfromtheturbogeneratorrotorwithdirectcooling AT dumitriul steadystatethermalfieldanalysisfromtheturbogeneratorrotorwithdirectcooling AT voicun steadystatethermalfieldanalysisfromtheturbogeneratorrotorwithdirectcooling AT iordachem steadystatethermalfieldanalysisfromtheturbogeneratorrotorwithdirectcooling |
_version_ |
1725915361168064512 |