Development of in-situ fatigue crack observing system for rotating bending fatigue testing machine

To substitute for a traditional replication technique, an in-situ fatigue crack observing system for rotating bending testing machine has been newly developed. For verifying performance of this observing system, fatigue tests were carried out by using fatigue specimen having a small artificial def...

Full description

Bibliographic Details
Main Authors: B. Lian, A. Ueno, T. Iwashita
Format: Article
Language:English
Published: Gruppo Italiano Frattura 2016-02-01
Series:Frattura ed Integrità Strutturale
Subjects:
Online Access:http://www.gruppofrattura.it/pdf/rivista/numero35/numero_35_art_44.pdf
Description
Summary:To substitute for a traditional replication technique, an in-situ fatigue crack observing system for rotating bending testing machine has been newly developed. For verifying performance of this observing system, fatigue tests were carried out by using fatigue specimen having a small artificial defect. It is proved that this system can be detect a small fatigue crack and its propagation behavior.
ISSN:1971-8993
1971-8993