A new method for determination of toluene-2,4-diamine and toluene-2,6-diamine in workplace air

Background: Toluenediamines are harmful substances. Toluene-2,4-diamine has been assigned to Carcinogen 1B hazard class, pursuant to Regulation (European Community – EC) No. 1272/2008 of the European Parliament and of the Council, and toluene- 2,6-diamine to Mutagen 2 hazard class. The main routes o...

Full description

Bibliographic Details
Main Authors: Joanna Kowalska, Anna Jeżewska
Format: Article
Language:English
Published: Nofer Institute of Occupational Medicine 2017-08-01
Series:Medycyna Pracy
Subjects:
Online Access:http://medpr.imp.lodz.pl/Nowa-metoda-oznaczania-tolueno-2-4-diaminy-i-tolueno-2-6-diaminy-w-powietrzu-na-stanowisku-pracy,65775,0,2.html
id doaj-d48eb5806edd41108feb77fbb3523444
record_format Article
spelling doaj-d48eb5806edd41108feb77fbb35234442020-11-24T22:31:08ZengNofer Institute of Occupational MedicineMedycyna Pracy0465-58932353-13392017-08-0168449750510.13075/mp.5893.00552A new method for determination of toluene-2,4-diamine and toluene-2,6-diamine in workplace airJoanna KowalskaAnna JeżewskaBackground: Toluenediamines are harmful substances. Toluene-2,4-diamine has been assigned to Carcinogen 1B hazard class, pursuant to Regulation (European Community – EC) No. 1272/2008 of the European Parliament and of the Council, and toluene- 2,6-diamine to Mutagen 2 hazard class. The main routes of exposure to toluene-2,4-diamine and toluene-2,6-diamine are via the respiratory tract and the skin. Toluene-2,4-diamine and toluene-2,6-diamine occur in the work environment in Poland. The aim of this study was to develop and validate a method for the determination of toluene-2,4-diamine and toluene-2,6-diamine that allows the simultaneous determination of their concentrations in the workplace air by personal sampling. Material and Methods: Determination of toluene-2,4-diamine and toluene-2,6-diamine derivatives in acetonitrile were carried out by means of liquid chromatography with a diode assay detector. The method involves passing amine-containing air through sulfuric acidtreated glass fiber filter, washing out the substance settled on the filter, using water and solution of sodium hydroxide, followed by the extraction with toluene, reaction with 3,5-dinitobenzoyl chloride, replacement of dissolvent with acetonitrile and analysis of obtained solution. Results: The method developed in this study enables the researcher to determine the content of toluene-2,4-diamine and toluene-2,6-diamine in the presence of other hazardous substances. In the specified measuring range (2.88–57.6 μg/ml) calibration curves are linear. Under the optimized conditions of determination, the limit of detection (LOD) values achieved: 51.36 ng/ml for toluene-2,4-diamine and 52.93 ng/ml for toluene-2,6-diamine. Conclusions: This method makes it possible to determine the concentration of toluene-2,4-diamine and toluene-2,6-diamine in the workplace air within the specified measuring range of 0.004–0.08 mg/m3 (for air sample volume of 720 l). Med Pr 2017;68(4):497–505http://medpr.imp.lodz.pl/Nowa-metoda-oznaczania-tolueno-2-4-diaminy-i-tolueno-2-6-diaminy-w-powietrzu-na-stanowisku-pracy,65775,0,2.htmlworkplacecarcinogenair analysis diaminotoluenedinitrobenzoyl chlorideHPLC
collection DOAJ
language English
format Article
sources DOAJ
author Joanna Kowalska
Anna Jeżewska
spellingShingle Joanna Kowalska
Anna Jeżewska
A new method for determination of toluene-2,4-diamine and toluene-2,6-diamine in workplace air
Medycyna Pracy
workplace
carcinogen
air analysis diaminotoluene
dinitrobenzoyl chloride
HPLC
author_facet Joanna Kowalska
Anna Jeżewska
author_sort Joanna Kowalska
title A new method for determination of toluene-2,4-diamine and toluene-2,6-diamine in workplace air
title_short A new method for determination of toluene-2,4-diamine and toluene-2,6-diamine in workplace air
title_full A new method for determination of toluene-2,4-diamine and toluene-2,6-diamine in workplace air
title_fullStr A new method for determination of toluene-2,4-diamine and toluene-2,6-diamine in workplace air
title_full_unstemmed A new method for determination of toluene-2,4-diamine and toluene-2,6-diamine in workplace air
title_sort new method for determination of toluene-2,4-diamine and toluene-2,6-diamine in workplace air
publisher Nofer Institute of Occupational Medicine
series Medycyna Pracy
issn 0465-5893
2353-1339
publishDate 2017-08-01
description Background: Toluenediamines are harmful substances. Toluene-2,4-diamine has been assigned to Carcinogen 1B hazard class, pursuant to Regulation (European Community – EC) No. 1272/2008 of the European Parliament and of the Council, and toluene- 2,6-diamine to Mutagen 2 hazard class. The main routes of exposure to toluene-2,4-diamine and toluene-2,6-diamine are via the respiratory tract and the skin. Toluene-2,4-diamine and toluene-2,6-diamine occur in the work environment in Poland. The aim of this study was to develop and validate a method for the determination of toluene-2,4-diamine and toluene-2,6-diamine that allows the simultaneous determination of their concentrations in the workplace air by personal sampling. Material and Methods: Determination of toluene-2,4-diamine and toluene-2,6-diamine derivatives in acetonitrile were carried out by means of liquid chromatography with a diode assay detector. The method involves passing amine-containing air through sulfuric acidtreated glass fiber filter, washing out the substance settled on the filter, using water and solution of sodium hydroxide, followed by the extraction with toluene, reaction with 3,5-dinitobenzoyl chloride, replacement of dissolvent with acetonitrile and analysis of obtained solution. Results: The method developed in this study enables the researcher to determine the content of toluene-2,4-diamine and toluene-2,6-diamine in the presence of other hazardous substances. In the specified measuring range (2.88–57.6 μg/ml) calibration curves are linear. Under the optimized conditions of determination, the limit of detection (LOD) values achieved: 51.36 ng/ml for toluene-2,4-diamine and 52.93 ng/ml for toluene-2,6-diamine. Conclusions: This method makes it possible to determine the concentration of toluene-2,4-diamine and toluene-2,6-diamine in the workplace air within the specified measuring range of 0.004–0.08 mg/m3 (for air sample volume of 720 l). Med Pr 2017;68(4):497–505
topic workplace
carcinogen
air analysis diaminotoluene
dinitrobenzoyl chloride
HPLC
url http://medpr.imp.lodz.pl/Nowa-metoda-oznaczania-tolueno-2-4-diaminy-i-tolueno-2-6-diaminy-w-powietrzu-na-stanowisku-pracy,65775,0,2.html
work_keys_str_mv AT joannakowalska anewmethodfordeterminationoftoluene24diamineandtoluene26diamineinworkplaceair
AT annajezewska anewmethodfordeterminationoftoluene24diamineandtoluene26diamineinworkplaceair
AT joannakowalska newmethodfordeterminationoftoluene24diamineandtoluene26diamineinworkplaceair
AT annajezewska newmethodfordeterminationoftoluene24diamineandtoluene26diamineinworkplaceair
_version_ 1725738633331212288