Sensors Auto-calibration Method - Using Programmable Interface Circuit Front-end

In this paper we present a standard auto-calibration method of sensors. The purpose is to correct the accumulated errors at the sensor output. A universal conditioning circuit is used with the sensor, and the transfer function of the measurement chain is periodically corrected according to the progr...

Full description

Bibliographic Details
Main Authors: D. Kourtiche, M. Nadi, M. Kouider
Format: Article
Language:English
Published: MDPI AG 2003-10-01
Series:Sensors
Subjects:
Online Access:http://www.mdpi.com/1424-8220/3/10/491/
id doaj-d442e9ef38be4e4b8eb9ba37142aa6c4
record_format Article
spelling doaj-d442e9ef38be4e4b8eb9ba37142aa6c42020-11-24T21:10:43ZengMDPI AGSensors1424-82202003-10-0131049149710.3390/s31000491Sensors Auto-calibration Method - Using Programmable Interface Circuit Front-endD. KourticheM. NadiM. KouiderIn this paper we present a standard auto-calibration method of sensors. The purpose is to correct the accumulated errors at the sensor output. A universal conditioning circuit is used with the sensor, and the transfer function of the measurement chain is periodically corrected according to the progressive correction method. References physical inputs are used to allow the adjustment of the measurement and to calculate the calibration coefficients. Test results obtained using this method present a considerable enhancement of the measurement accuracy and a good handling of cross-sensitivity problem.http://www.mdpi.com/1424-8220/3/10/491/sensors calibrationsensors interfacingsignals processingmeasurement errors
collection DOAJ
language English
format Article
sources DOAJ
author D. Kourtiche
M. Nadi
M. Kouider
spellingShingle D. Kourtiche
M. Nadi
M. Kouider
Sensors Auto-calibration Method - Using Programmable Interface Circuit Front-end
Sensors
sensors calibration
sensors interfacing
signals processing
measurement errors
author_facet D. Kourtiche
M. Nadi
M. Kouider
author_sort D. Kourtiche
title Sensors Auto-calibration Method - Using Programmable Interface Circuit Front-end
title_short Sensors Auto-calibration Method - Using Programmable Interface Circuit Front-end
title_full Sensors Auto-calibration Method - Using Programmable Interface Circuit Front-end
title_fullStr Sensors Auto-calibration Method - Using Programmable Interface Circuit Front-end
title_full_unstemmed Sensors Auto-calibration Method - Using Programmable Interface Circuit Front-end
title_sort sensors auto-calibration method - using programmable interface circuit front-end
publisher MDPI AG
series Sensors
issn 1424-8220
publishDate 2003-10-01
description In this paper we present a standard auto-calibration method of sensors. The purpose is to correct the accumulated errors at the sensor output. A universal conditioning circuit is used with the sensor, and the transfer function of the measurement chain is periodically corrected according to the progressive correction method. References physical inputs are used to allow the adjustment of the measurement and to calculate the calibration coefficients. Test results obtained using this method present a considerable enhancement of the measurement accuracy and a good handling of cross-sensitivity problem.
topic sensors calibration
sensors interfacing
signals processing
measurement errors
url http://www.mdpi.com/1424-8220/3/10/491/
work_keys_str_mv AT dkourtiche sensorsautocalibrationmethodusingprogrammableinterfacecircuitfrontend
AT mnadi sensorsautocalibrationmethodusingprogrammableinterfacecircuitfrontend
AT mkouider sensorsautocalibrationmethodusingprogrammableinterfacecircuitfrontend
_version_ 1716755533243875328