Successful Ablation of Cavotricuspid Isthmus-dependent Atrial Flutter Guided by Contact Force Vector in a Patient After a Tricuspid Valve Replacement

A 46-year-old man after a tricuspid valve replacement due to traumatic severe tricuspid regurgitation developed cavotricuspid isthmus-dependent counterclockwise atrial flutter. During a linear ablation using a contact force-sensing irrigated ablation catheter, the flutter could be terminated by a ra...

Full description

Bibliographic Details
Main Authors: Eri Goto, Kohki Nakamura, Takehito Sasaki, Shigeto Naito
Format: Article
Language:English
Published: Elsevier 2014-11-01
Series:Indian Pacing and Electrophysiology Journal
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S0972629216308208
id doaj-d43dbf7b4fd745c488bcbd439fdf29a1
record_format Article
spelling doaj-d43dbf7b4fd745c488bcbd439fdf29a12020-11-24T22:56:11ZengElsevierIndian Pacing and Electrophysiology Journal0972-62922014-11-0114630630810.1016/S0972-6292(16)30820-8Successful Ablation of Cavotricuspid Isthmus-dependent Atrial Flutter Guided by Contact Force Vector in a Patient After a Tricuspid Valve ReplacementEri GotoKohki NakamuraTakehito SasakiShigeto NaitoA 46-year-old man after a tricuspid valve replacement due to traumatic severe tricuspid regurgitation developed cavotricuspid isthmus-dependent counterclockwise atrial flutter. During a linear ablation using a contact force-sensing irrigated ablation catheter, the flutter could be terminated by a radiofrequency application within a deep pouch just below the bioprosthetic tricuspid valve.http://www.sciencedirect.com/science/article/pii/S0972629216308208Cavotricuspid isthmus-dependent atrial flutterContact force vectorTricuspid valve replacementCatheter ablation
collection DOAJ
language English
format Article
sources DOAJ
author Eri Goto
Kohki Nakamura
Takehito Sasaki
Shigeto Naito
spellingShingle Eri Goto
Kohki Nakamura
Takehito Sasaki
Shigeto Naito
Successful Ablation of Cavotricuspid Isthmus-dependent Atrial Flutter Guided by Contact Force Vector in a Patient After a Tricuspid Valve Replacement
Indian Pacing and Electrophysiology Journal
Cavotricuspid isthmus-dependent atrial flutter
Contact force vector
Tricuspid valve replacement
Catheter ablation
author_facet Eri Goto
Kohki Nakamura
Takehito Sasaki
Shigeto Naito
author_sort Eri Goto
title Successful Ablation of Cavotricuspid Isthmus-dependent Atrial Flutter Guided by Contact Force Vector in a Patient After a Tricuspid Valve Replacement
title_short Successful Ablation of Cavotricuspid Isthmus-dependent Atrial Flutter Guided by Contact Force Vector in a Patient After a Tricuspid Valve Replacement
title_full Successful Ablation of Cavotricuspid Isthmus-dependent Atrial Flutter Guided by Contact Force Vector in a Patient After a Tricuspid Valve Replacement
title_fullStr Successful Ablation of Cavotricuspid Isthmus-dependent Atrial Flutter Guided by Contact Force Vector in a Patient After a Tricuspid Valve Replacement
title_full_unstemmed Successful Ablation of Cavotricuspid Isthmus-dependent Atrial Flutter Guided by Contact Force Vector in a Patient After a Tricuspid Valve Replacement
title_sort successful ablation of cavotricuspid isthmus-dependent atrial flutter guided by contact force vector in a patient after a tricuspid valve replacement
publisher Elsevier
series Indian Pacing and Electrophysiology Journal
issn 0972-6292
publishDate 2014-11-01
description A 46-year-old man after a tricuspid valve replacement due to traumatic severe tricuspid regurgitation developed cavotricuspid isthmus-dependent counterclockwise atrial flutter. During a linear ablation using a contact force-sensing irrigated ablation catheter, the flutter could be terminated by a radiofrequency application within a deep pouch just below the bioprosthetic tricuspid valve.
topic Cavotricuspid isthmus-dependent atrial flutter
Contact force vector
Tricuspid valve replacement
Catheter ablation
url http://www.sciencedirect.com/science/article/pii/S0972629216308208
work_keys_str_mv AT erigoto successfulablationofcavotricuspidisthmusdependentatrialflutterguidedbycontactforcevectorinapatientafteratricuspidvalvereplacement
AT kohkinakamura successfulablationofcavotricuspidisthmusdependentatrialflutterguidedbycontactforcevectorinapatientafteratricuspidvalvereplacement
AT takehitosasaki successfulablationofcavotricuspidisthmusdependentatrialflutterguidedbycontactforcevectorinapatientafteratricuspidvalvereplacement
AT shigetonaito successfulablationofcavotricuspidisthmusdependentatrialflutterguidedbycontactforcevectorinapatientafteratricuspidvalvereplacement
_version_ 1725654405275975680