Effects of column density on I<sub>2</sub> spectroscopy and a determination of I<sub>2</sub> absorption cross section at 500 nm

The use of ro-vibronic spectra of I<sub>2</sub> in the region of 543 nm to 578 nm as reference spectra for atmospheric Differential Optical Absorption Spectroscopy is studied. It is shown that the retrieval of atmospheric column densities with Differential Optical Absorption Spectroscopy...

Full description

Bibliographic Details
Main Authors: P. Spietz, J. Gómez Martín, J. P. Burrows
Format: Article
Language:English
Published: Copernicus Publications 2006-01-01
Series:Atmospheric Chemistry and Physics
Online Access:http://www.atmos-chem-phys.net/6/2177/2006/acp-6-2177-2006.pdf
id doaj-d38ca09c68a848fc8252d603e62db710
record_format Article
spelling doaj-d38ca09c68a848fc8252d603e62db7102020-11-24T20:46:25ZengCopernicus PublicationsAtmospheric Chemistry and Physics1680-73161680-73242006-01-016821772191Effects of column density on I<sub>2</sub> spectroscopy and a determination of I<sub>2</sub> absorption cross section at 500 nmP. SpietzJ. Gómez MartínJ. P. BurrowsThe use of ro-vibronic spectra of I<sub>2</sub> in the region of 543 nm to 578 nm as reference spectra for atmospheric Differential Optical Absorption Spectroscopy is studied. It is shown that the retrieval of atmospheric column densities with Differential Optical Absorption Spectroscopy set-ups at FWHM at and above 1 nm depends critically on the column density, under which the used reference spectrum was recorded. Systematic overestimation of the comparatively low atmospheric column density of I<sub>2</sub> of the order of 13% is possible. Under low pressure conditions relevant in laboratory studies, the systematic deviations may grow up to 45%. To avoid such effects with respect to field measurements, new reference spectra of I<sub>2</sub> were determined under column density of the order of 10<sup>16</sup> cm<sup>-2</sup> close to that expected for an atmospheric measurement. Two typical configurations of Differential Optical Absorption Spectroscopy, which use grating spectrometers, were chosen for the spectroscopic set-up. One spectrum was recorded at similar resolution (0.25 nm FWHM) but finer binning (0.035 nm/pixel) than previously published data. For the other (0.59 nm FWHM, 0.154 nm/pixel) no previously published spectra exist. Wavelength calibration is accurate to &plusmn;0.04,nm and &plusmn;0.11 nm respectively. The absorption cross section for the recordings was determined under low column density with an accuracy of &plusmn;4% and &plusmn;3% respectively. The absolute absorption cross section of I<sub>2</sub> at 500 nm (wavelength: in standard air) in the continuum absorption region was determined using a method independent of iodine vapour pressure. Obtained was &sigma;<sub>I<sub>2</sub></sub> (500 nm)=(2.18<sub>6</sub>&plusmn;0.02<sub>1</sub>&middot;10<sup>-18</sup> cm<sup>2</sup> in very good agreement with previously published results, but at 50% smaller uncertainty. From this and previously published results a weighted average of &sigma;<sub>I<sub>2</sub></sub>(500 nm)=(2.19<sub>1</sub>&plusmn;0.02)&middot;10<sup>-18</sup> cm<sup>2</sup> is determined.http://www.atmos-chem-phys.net/6/2177/2006/acp-6-2177-2006.pdf
collection DOAJ
language English
format Article
sources DOAJ
author P. Spietz
J. Gómez Martín
J. P. Burrows
spellingShingle P. Spietz
J. Gómez Martín
J. P. Burrows
Effects of column density on I<sub>2</sub> spectroscopy and a determination of I<sub>2</sub> absorption cross section at 500 nm
Atmospheric Chemistry and Physics
author_facet P. Spietz
J. Gómez Martín
J. P. Burrows
author_sort P. Spietz
title Effects of column density on I<sub>2</sub> spectroscopy and a determination of I<sub>2</sub> absorption cross section at 500 nm
title_short Effects of column density on I<sub>2</sub> spectroscopy and a determination of I<sub>2</sub> absorption cross section at 500 nm
title_full Effects of column density on I<sub>2</sub> spectroscopy and a determination of I<sub>2</sub> absorption cross section at 500 nm
title_fullStr Effects of column density on I<sub>2</sub> spectroscopy and a determination of I<sub>2</sub> absorption cross section at 500 nm
title_full_unstemmed Effects of column density on I<sub>2</sub> spectroscopy and a determination of I<sub>2</sub> absorption cross section at 500 nm
title_sort effects of column density on i<sub>2</sub> spectroscopy and a determination of i<sub>2</sub> absorption cross section at 500 nm
publisher Copernicus Publications
series Atmospheric Chemistry and Physics
issn 1680-7316
1680-7324
publishDate 2006-01-01
description The use of ro-vibronic spectra of I<sub>2</sub> in the region of 543 nm to 578 nm as reference spectra for atmospheric Differential Optical Absorption Spectroscopy is studied. It is shown that the retrieval of atmospheric column densities with Differential Optical Absorption Spectroscopy set-ups at FWHM at and above 1 nm depends critically on the column density, under which the used reference spectrum was recorded. Systematic overestimation of the comparatively low atmospheric column density of I<sub>2</sub> of the order of 13% is possible. Under low pressure conditions relevant in laboratory studies, the systematic deviations may grow up to 45%. To avoid such effects with respect to field measurements, new reference spectra of I<sub>2</sub> were determined under column density of the order of 10<sup>16</sup> cm<sup>-2</sup> close to that expected for an atmospheric measurement. Two typical configurations of Differential Optical Absorption Spectroscopy, which use grating spectrometers, were chosen for the spectroscopic set-up. One spectrum was recorded at similar resolution (0.25 nm FWHM) but finer binning (0.035 nm/pixel) than previously published data. For the other (0.59 nm FWHM, 0.154 nm/pixel) no previously published spectra exist. Wavelength calibration is accurate to &plusmn;0.04,nm and &plusmn;0.11 nm respectively. The absorption cross section for the recordings was determined under low column density with an accuracy of &plusmn;4% and &plusmn;3% respectively. The absolute absorption cross section of I<sub>2</sub> at 500 nm (wavelength: in standard air) in the continuum absorption region was determined using a method independent of iodine vapour pressure. Obtained was &sigma;<sub>I<sub>2</sub></sub> (500 nm)=(2.18<sub>6</sub>&plusmn;0.02<sub>1</sub>&middot;10<sup>-18</sup> cm<sup>2</sup> in very good agreement with previously published results, but at 50% smaller uncertainty. From this and previously published results a weighted average of &sigma;<sub>I<sub>2</sub></sub>(500 nm)=(2.19<sub>1</sub>&plusmn;0.02)&middot;10<sup>-18</sup> cm<sup>2</sup> is determined.
url http://www.atmos-chem-phys.net/6/2177/2006/acp-6-2177-2006.pdf
work_keys_str_mv AT pspietz effectsofcolumndensityonisub2subspectroscopyandadeterminationofisub2subabsorptioncrosssectionat500nm
AT jgomezmartin effectsofcolumndensityonisub2subspectroscopyandadeterminationofisub2subabsorptioncrosssectionat500nm
AT jpburrows effectsofcolumndensityonisub2subspectroscopyandadeterminationofisub2subabsorptioncrosssectionat500nm
_version_ 1716812678365708288