Perfusion index versus non-invasive hemodynamic parameters during insertion of i-gel, classic laryngeal mask airway and endotracheal tube

Background: Perfusion index (PI) is a non-invasive numerical value of peripheral perfusion obtained from a pulse oximeter. In this study, we evaluated the efficacy of PI for detecting haemodynamic stress responses to insertion of i-gel, laryngeal mask airway (LMA) and endotracheal tube and compare,...

Full description

Bibliographic Details
Main Authors: Hosam M Atef, Salah Abd Fattah, Mohammed Emad Abd Gaffer, Ahamed Abd Al Rahman
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2013-01-01
Series:Indian Journal of Anaesthesia
Subjects:
Online Access:http://www.ijaweb.org/article.asp?issn=0019-5049;year=2013;volume=57;issue=2;spage=156;epage=162;aulast=Atef
id doaj-d38704ffa5394963af99f8197e9b1770
record_format Article
spelling doaj-d38704ffa5394963af99f8197e9b17702020-11-25T01:03:42ZengWolters Kluwer Medknow PublicationsIndian Journal of Anaesthesia0019-50492013-01-0157215616210.4103/0019-5049.111843Perfusion index versus non-invasive hemodynamic parameters during insertion of i-gel, classic laryngeal mask airway and endotracheal tubeHosam M AtefSalah Abd FattahMohammed Emad Abd GafferAhamed Abd Al RahmanBackground: Perfusion index (PI) is a non-invasive numerical value of peripheral perfusion obtained from a pulse oximeter. In this study, we evaluated the efficacy of PI for detecting haemodynamic stress responses to insertion of i-gel, laryngeal mask airway (LMA) and endotracheal tube and compare, its reliability with the conventional haemodynamic criteria in adults during general anaesthesia. Methods: Sixty patients scheduled for elective general surgery under general anaesthesia were randomised to three groups. (i-gel, LMA and ET groups ( n=20/group). Heart rate (HR) (positive if ≥10 bpm), systolic blood pressure (SBP), diastolic blood pressure (DBP) (positive if ≥15 mm Hg) and PI (positive if ≤10%) were monitored for 5 min after insertion. Main outcome measures: SBP, DBP, HR and PI were measured before induction of anaesthesia and before and after insertion of the airway device. Results: Insertion of airway devices produced significant increases in HR, SBP and DBP in LMA and ET groups. Moreover, PI was decreased significantly by 40%, 100% and 100% in the three groups. Using the PI criterion, the sensitivity was 100% (CI 82.4-100.0%). Regarding the SBP and DBP criterions, the sensitivity was 44.4% (CI 24.6-66.3%), 55.6% (CI 33.7-75.4%) respectively. Also, significant change in the mean PI over time (from pre-insertion value to the 1 st min, 3 rd min, until the 4 th min after insertion without regard the device type), ( P<0.001). Conclusion: PI is a reliable and easier alternative to conventional haemodynamic criteria for detection of stress response to insertion of i-gel, LMA and ET during propofol fentanyl isoflurane anaesthesia in adult patients.http://www.ijaweb.org/article.asp?issn=0019-5049;year=2013;volume=57;issue=2;spage=156;epage=162;aulast=AtefAirway managementclassic laryngeal mask airwayendotracheal tubeequipment designi-gelintubationlaryngeal masksperfusion indexstress response
collection DOAJ
language English
format Article
sources DOAJ
author Hosam M Atef
Salah Abd Fattah
Mohammed Emad Abd Gaffer
Ahamed Abd Al Rahman
spellingShingle Hosam M Atef
Salah Abd Fattah
Mohammed Emad Abd Gaffer
Ahamed Abd Al Rahman
Perfusion index versus non-invasive hemodynamic parameters during insertion of i-gel, classic laryngeal mask airway and endotracheal tube
Indian Journal of Anaesthesia
Airway management
classic laryngeal mask airway
endotracheal tube
equipment design
i-gel
intubation
laryngeal masks
perfusion index
stress response
author_facet Hosam M Atef
Salah Abd Fattah
Mohammed Emad Abd Gaffer
Ahamed Abd Al Rahman
author_sort Hosam M Atef
title Perfusion index versus non-invasive hemodynamic parameters during insertion of i-gel, classic laryngeal mask airway and endotracheal tube
title_short Perfusion index versus non-invasive hemodynamic parameters during insertion of i-gel, classic laryngeal mask airway and endotracheal tube
title_full Perfusion index versus non-invasive hemodynamic parameters during insertion of i-gel, classic laryngeal mask airway and endotracheal tube
title_fullStr Perfusion index versus non-invasive hemodynamic parameters during insertion of i-gel, classic laryngeal mask airway and endotracheal tube
title_full_unstemmed Perfusion index versus non-invasive hemodynamic parameters during insertion of i-gel, classic laryngeal mask airway and endotracheal tube
title_sort perfusion index versus non-invasive hemodynamic parameters during insertion of i-gel, classic laryngeal mask airway and endotracheal tube
publisher Wolters Kluwer Medknow Publications
series Indian Journal of Anaesthesia
issn 0019-5049
publishDate 2013-01-01
description Background: Perfusion index (PI) is a non-invasive numerical value of peripheral perfusion obtained from a pulse oximeter. In this study, we evaluated the efficacy of PI for detecting haemodynamic stress responses to insertion of i-gel, laryngeal mask airway (LMA) and endotracheal tube and compare, its reliability with the conventional haemodynamic criteria in adults during general anaesthesia. Methods: Sixty patients scheduled for elective general surgery under general anaesthesia were randomised to three groups. (i-gel, LMA and ET groups ( n=20/group). Heart rate (HR) (positive if ≥10 bpm), systolic blood pressure (SBP), diastolic blood pressure (DBP) (positive if ≥15 mm Hg) and PI (positive if ≤10%) were monitored for 5 min after insertion. Main outcome measures: SBP, DBP, HR and PI were measured before induction of anaesthesia and before and after insertion of the airway device. Results: Insertion of airway devices produced significant increases in HR, SBP and DBP in LMA and ET groups. Moreover, PI was decreased significantly by 40%, 100% and 100% in the three groups. Using the PI criterion, the sensitivity was 100% (CI 82.4-100.0%). Regarding the SBP and DBP criterions, the sensitivity was 44.4% (CI 24.6-66.3%), 55.6% (CI 33.7-75.4%) respectively. Also, significant change in the mean PI over time (from pre-insertion value to the 1 st min, 3 rd min, until the 4 th min after insertion without regard the device type), ( P<0.001). Conclusion: PI is a reliable and easier alternative to conventional haemodynamic criteria for detection of stress response to insertion of i-gel, LMA and ET during propofol fentanyl isoflurane anaesthesia in adult patients.
topic Airway management
classic laryngeal mask airway
endotracheal tube
equipment design
i-gel
intubation
laryngeal masks
perfusion index
stress response
url http://www.ijaweb.org/article.asp?issn=0019-5049;year=2013;volume=57;issue=2;spage=156;epage=162;aulast=Atef
work_keys_str_mv AT hosammatef perfusionindexversusnoninvasivehemodynamicparametersduringinsertionofigelclassiclaryngealmaskairwayandendotrachealtube
AT salahabdfattah perfusionindexversusnoninvasivehemodynamicparametersduringinsertionofigelclassiclaryngealmaskairwayandendotrachealtube
AT mohammedemadabdgaffer perfusionindexversusnoninvasivehemodynamicparametersduringinsertionofigelclassiclaryngealmaskairwayandendotrachealtube
AT ahamedabdalrahman perfusionindexversusnoninvasivehemodynamicparametersduringinsertionofigelclassiclaryngealmaskairwayandendotrachealtube
_version_ 1725199834365820928