Cone-Beam Computed Tomography Deblurring Using an Overrelaxed Chambolle-Pock Algorithm

The scatter contamination and photon starvation artifacts are less severe due to the smaller cone angle and attenuation associated with the smaller sample size in the microstructure imaging (MSI) with a cone-beam CT (CBCT) instrument. Compared with other artifacts, the blurring effect is more critic...

Full description

Bibliographic Details
Main Authors: Chen Luo, Qiao Liu, Shutao Gong, Chunlin Yang, Xiuhua Hu, Ke Nie, Tianye Niu
Format: Article
Language:English
Published: IEEE 2019-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/8546732/
id doaj-d3841841271547499050349e135e16a4
record_format Article
spelling doaj-d3841841271547499050349e135e16a42021-03-29T22:08:46ZengIEEEIEEE Access2169-35362019-01-0171247125910.1109/ACCESS.2018.28832978546732Cone-Beam Computed Tomography Deblurring Using an Overrelaxed Chambolle-Pock AlgorithmChen Luo0https://orcid.org/0000-0002-6105-4657Qiao Liu1Shutao Gong2Chunlin Yang3Xiuhua Hu4Ke Nie5Tianye Niu6https://orcid.org/0000-0003-4181-3641Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Institute of Translational Medicine, Zhejiang University, Hangzhou, ChinaSir Run Run Shaw Hospital, Zhejiang University School of Medicine, Institute of Translational Medicine, Zhejiang University, Hangzhou, ChinaSir Run Run Shaw Hospital, Zhejiang University School of Medicine, Institute of Translational Medicine, Zhejiang University, Hangzhou, ChinaSir Run Run Shaw Hospital, Zhejiang University School of Medicine, Institute of Translational Medicine, Zhejiang University, Hangzhou, ChinaDepartment of Radiology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, ChinaDepartment of Radiation Oncology, Rutgers—Robert Wood Johnson Medical School, Rutgers—Cancer Institute of New Jersey, New Brunswick, NJ, USASir Run Run Shaw Hospital, Zhejiang University School of Medicine, Institute of Translational Medicine, Zhejiang University, Hangzhou, ChinaThe scatter contamination and photon starvation artifacts are less severe due to the smaller cone angle and attenuation associated with the smaller sample size in the microstructure imaging (MSI) with a cone-beam CT (CBCT) instrument. Compared with other artifacts, the blurring effect is more critical in the MSI due to the direct degradation of spatial resolution. An efficient deblurring method using the line integral images is proposed in this paper. The point spread function (PSF) of the CBCT system is simplified as a 2D Gaussian kernel function with the spatially invariant assumption. The deblurred line integral images are calculated using the iterative optimization process with an objective function in which the blurring effects are described by the convolution between the simplified PSF and the real line integral image. A first-order primal–dual algorithm is applied and derived to solve the real line integral image due to its fast convergence and high computational efficiency. The performance of the proposed method is evaluated using various datasets, including a digital phantom, a physical phantom, and a laboratory mouse. The spatial resolution, noise distribution, and computation cost of the proposed method are compared with those of a 3D image domain deconvolution method. In addition to the well-suppressed blurring effects in the CBCT images, the proposed method provides a higher computational efficiency than the 3D approach. The proposed method is thus practical and attractive to be incorporated into the data processing workflow of the CBCT instrument of MSI.https://ieeexplore.ieee.org/document/8546732/Computed tomographydeconvolutionspatial resolution
collection DOAJ
language English
format Article
sources DOAJ
author Chen Luo
Qiao Liu
Shutao Gong
Chunlin Yang
Xiuhua Hu
Ke Nie
Tianye Niu
spellingShingle Chen Luo
Qiao Liu
Shutao Gong
Chunlin Yang
Xiuhua Hu
Ke Nie
Tianye Niu
Cone-Beam Computed Tomography Deblurring Using an Overrelaxed Chambolle-Pock Algorithm
IEEE Access
Computed tomography
deconvolution
spatial resolution
author_facet Chen Luo
Qiao Liu
Shutao Gong
Chunlin Yang
Xiuhua Hu
Ke Nie
Tianye Niu
author_sort Chen Luo
title Cone-Beam Computed Tomography Deblurring Using an Overrelaxed Chambolle-Pock Algorithm
title_short Cone-Beam Computed Tomography Deblurring Using an Overrelaxed Chambolle-Pock Algorithm
title_full Cone-Beam Computed Tomography Deblurring Using an Overrelaxed Chambolle-Pock Algorithm
title_fullStr Cone-Beam Computed Tomography Deblurring Using an Overrelaxed Chambolle-Pock Algorithm
title_full_unstemmed Cone-Beam Computed Tomography Deblurring Using an Overrelaxed Chambolle-Pock Algorithm
title_sort cone-beam computed tomography deblurring using an overrelaxed chambolle-pock algorithm
publisher IEEE
series IEEE Access
issn 2169-3536
publishDate 2019-01-01
description The scatter contamination and photon starvation artifacts are less severe due to the smaller cone angle and attenuation associated with the smaller sample size in the microstructure imaging (MSI) with a cone-beam CT (CBCT) instrument. Compared with other artifacts, the blurring effect is more critical in the MSI due to the direct degradation of spatial resolution. An efficient deblurring method using the line integral images is proposed in this paper. The point spread function (PSF) of the CBCT system is simplified as a 2D Gaussian kernel function with the spatially invariant assumption. The deblurred line integral images are calculated using the iterative optimization process with an objective function in which the blurring effects are described by the convolution between the simplified PSF and the real line integral image. A first-order primal–dual algorithm is applied and derived to solve the real line integral image due to its fast convergence and high computational efficiency. The performance of the proposed method is evaluated using various datasets, including a digital phantom, a physical phantom, and a laboratory mouse. The spatial resolution, noise distribution, and computation cost of the proposed method are compared with those of a 3D image domain deconvolution method. In addition to the well-suppressed blurring effects in the CBCT images, the proposed method provides a higher computational efficiency than the 3D approach. The proposed method is thus practical and attractive to be incorporated into the data processing workflow of the CBCT instrument of MSI.
topic Computed tomography
deconvolution
spatial resolution
url https://ieeexplore.ieee.org/document/8546732/
work_keys_str_mv AT chenluo conebeamcomputedtomographydeblurringusinganoverrelaxedchambollepockalgorithm
AT qiaoliu conebeamcomputedtomographydeblurringusinganoverrelaxedchambollepockalgorithm
AT shutaogong conebeamcomputedtomographydeblurringusinganoverrelaxedchambollepockalgorithm
AT chunlinyang conebeamcomputedtomographydeblurringusinganoverrelaxedchambollepockalgorithm
AT xiuhuahu conebeamcomputedtomographydeblurringusinganoverrelaxedchambollepockalgorithm
AT kenie conebeamcomputedtomographydeblurringusinganoverrelaxedchambollepockalgorithm
AT tianyeniu conebeamcomputedtomographydeblurringusinganoverrelaxedchambollepockalgorithm
_version_ 1724192109155581952