Development and measurement of a 365 NM UV LED irradiance source
UV LED has been widely used in various fields such as medical disinfection and biochemical detection, especially in UV curing. Compared with traditional high-voltage mercury lamp, UV LED shows large differences both in the spectral power distribution and irradiance, which may cause up to 20% error i...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2021-12-01
|
Series: | Measurement: Sensors |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2665917421001161 |
id |
doaj-d37af2745f7342479756a3274a797fd3 |
---|---|
record_format |
Article |
spelling |
doaj-d37af2745f7342479756a3274a797fd32021-10-09T04:41:27ZengElsevierMeasurement: Sensors2665-91742021-12-0118100153Development and measurement of a 365 NM UV LED irradiance sourceTiecheng Li0Fangsheng Lin1Muyao Ji2Biyong Huang3Weihai Cheng4Leibing Shi5Ming Xia6Liping Wang7Shanghai Institute of Measurement and Testing Technology, Shanghai, PR ChinaCorresponding author.; Shanghai Institute of Measurement and Testing Technology, Shanghai, PR ChinaShanghai Institute of Measurement and Testing Technology, Shanghai, PR ChinaShanghai Institute of Measurement and Testing Technology, Shanghai, PR ChinaShanghai Institute of Measurement and Testing Technology, Shanghai, PR ChinaShanghai Institute of Measurement and Testing Technology, Shanghai, PR ChinaShanghai Institute of Measurement and Testing Technology, Shanghai, PR ChinaShanghai Institute of Measurement and Testing Technology, Shanghai, PR ChinaUV LED has been widely used in various fields such as medical disinfection and biochemical detection, especially in UV curing. Compared with traditional high-voltage mercury lamp, UV LED shows large differences both in the spectral power distribution and irradiance, which may cause up to 20% error in calibration. A 365 nm UV LED source has been developed and measured, which is made of UV LEDs, temperature control module, integrating sphere, circuit and monitoring module. The experiment results indicate that the irradiance of about 884 mW/cm2 meets the actual requirements of the curing industry, and the stability of 1.0% (15 min) and uniformity of 1.6% are in compliance with the calibration regulation.http://www.sciencedirect.com/science/article/pii/S2665917421001161UV LEDIrradiance sourceIntegrating sphereCalibration |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Tiecheng Li Fangsheng Lin Muyao Ji Biyong Huang Weihai Cheng Leibing Shi Ming Xia Liping Wang |
spellingShingle |
Tiecheng Li Fangsheng Lin Muyao Ji Biyong Huang Weihai Cheng Leibing Shi Ming Xia Liping Wang Development and measurement of a 365 NM UV LED irradiance source Measurement: Sensors UV LED Irradiance source Integrating sphere Calibration |
author_facet |
Tiecheng Li Fangsheng Lin Muyao Ji Biyong Huang Weihai Cheng Leibing Shi Ming Xia Liping Wang |
author_sort |
Tiecheng Li |
title |
Development and measurement of a 365 NM UV LED irradiance source |
title_short |
Development and measurement of a 365 NM UV LED irradiance source |
title_full |
Development and measurement of a 365 NM UV LED irradiance source |
title_fullStr |
Development and measurement of a 365 NM UV LED irradiance source |
title_full_unstemmed |
Development and measurement of a 365 NM UV LED irradiance source |
title_sort |
development and measurement of a 365 nm uv led irradiance source |
publisher |
Elsevier |
series |
Measurement: Sensors |
issn |
2665-9174 |
publishDate |
2021-12-01 |
description |
UV LED has been widely used in various fields such as medical disinfection and biochemical detection, especially in UV curing. Compared with traditional high-voltage mercury lamp, UV LED shows large differences both in the spectral power distribution and irradiance, which may cause up to 20% error in calibration. A 365 nm UV LED source has been developed and measured, which is made of UV LEDs, temperature control module, integrating sphere, circuit and monitoring module. The experiment results indicate that the irradiance of about 884 mW/cm2 meets the actual requirements of the curing industry, and the stability of 1.0% (15 min) and uniformity of 1.6% are in compliance with the calibration regulation. |
topic |
UV LED Irradiance source Integrating sphere Calibration |
url |
http://www.sciencedirect.com/science/article/pii/S2665917421001161 |
work_keys_str_mv |
AT tiechengli developmentandmeasurementofa365nmuvledirradiancesource AT fangshenglin developmentandmeasurementofa365nmuvledirradiancesource AT muyaoji developmentandmeasurementofa365nmuvledirradiancesource AT biyonghuang developmentandmeasurementofa365nmuvledirradiancesource AT weihaicheng developmentandmeasurementofa365nmuvledirradiancesource AT leibingshi developmentandmeasurementofa365nmuvledirradiancesource AT mingxia developmentandmeasurementofa365nmuvledirradiancesource AT lipingwang developmentandmeasurementofa365nmuvledirradiancesource |
_version_ |
1716830561126842368 |