Development and measurement of a 365 NM UV LED irradiance source

UV LED has been widely used in various fields such as medical disinfection and biochemical detection, especially in UV curing. Compared with traditional high-voltage mercury lamp, UV LED shows large differences both in the spectral power distribution and irradiance, which may cause up to 20% error i...

Full description

Bibliographic Details
Main Authors: Tiecheng Li, Fangsheng Lin, Muyao Ji, Biyong Huang, Weihai Cheng, Leibing Shi, Ming Xia, Liping Wang
Format: Article
Language:English
Published: Elsevier 2021-12-01
Series:Measurement: Sensors
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2665917421001161
id doaj-d37af2745f7342479756a3274a797fd3
record_format Article
spelling doaj-d37af2745f7342479756a3274a797fd32021-10-09T04:41:27ZengElsevierMeasurement: Sensors2665-91742021-12-0118100153Development and measurement of a 365 NM UV LED irradiance sourceTiecheng Li0Fangsheng Lin1Muyao Ji2Biyong Huang3Weihai Cheng4Leibing Shi5Ming Xia6Liping Wang7Shanghai Institute of Measurement and Testing Technology, Shanghai, PR ChinaCorresponding author.; Shanghai Institute of Measurement and Testing Technology, Shanghai, PR ChinaShanghai Institute of Measurement and Testing Technology, Shanghai, PR ChinaShanghai Institute of Measurement and Testing Technology, Shanghai, PR ChinaShanghai Institute of Measurement and Testing Technology, Shanghai, PR ChinaShanghai Institute of Measurement and Testing Technology, Shanghai, PR ChinaShanghai Institute of Measurement and Testing Technology, Shanghai, PR ChinaShanghai Institute of Measurement and Testing Technology, Shanghai, PR ChinaUV LED has been widely used in various fields such as medical disinfection and biochemical detection, especially in UV curing. Compared with traditional high-voltage mercury lamp, UV LED shows large differences both in the spectral power distribution and irradiance, which may cause up to 20% error in calibration. A 365 nm UV LED source has been developed and measured, which is made of UV LEDs, temperature control module, integrating sphere, circuit and monitoring module. The experiment results indicate that the irradiance of about 884 mW/cm2 meets the actual requirements of the curing industry, and the stability of 1.0% (15 min) and uniformity of 1.6% are in compliance with the calibration regulation.http://www.sciencedirect.com/science/article/pii/S2665917421001161UV LEDIrradiance sourceIntegrating sphereCalibration
collection DOAJ
language English
format Article
sources DOAJ
author Tiecheng Li
Fangsheng Lin
Muyao Ji
Biyong Huang
Weihai Cheng
Leibing Shi
Ming Xia
Liping Wang
spellingShingle Tiecheng Li
Fangsheng Lin
Muyao Ji
Biyong Huang
Weihai Cheng
Leibing Shi
Ming Xia
Liping Wang
Development and measurement of a 365 NM UV LED irradiance source
Measurement: Sensors
UV LED
Irradiance source
Integrating sphere
Calibration
author_facet Tiecheng Li
Fangsheng Lin
Muyao Ji
Biyong Huang
Weihai Cheng
Leibing Shi
Ming Xia
Liping Wang
author_sort Tiecheng Li
title Development and measurement of a 365 NM UV LED irradiance source
title_short Development and measurement of a 365 NM UV LED irradiance source
title_full Development and measurement of a 365 NM UV LED irradiance source
title_fullStr Development and measurement of a 365 NM UV LED irradiance source
title_full_unstemmed Development and measurement of a 365 NM UV LED irradiance source
title_sort development and measurement of a 365 nm uv led irradiance source
publisher Elsevier
series Measurement: Sensors
issn 2665-9174
publishDate 2021-12-01
description UV LED has been widely used in various fields such as medical disinfection and biochemical detection, especially in UV curing. Compared with traditional high-voltage mercury lamp, UV LED shows large differences both in the spectral power distribution and irradiance, which may cause up to 20% error in calibration. A 365 nm UV LED source has been developed and measured, which is made of UV LEDs, temperature control module, integrating sphere, circuit and monitoring module. The experiment results indicate that the irradiance of about 884 mW/cm2 meets the actual requirements of the curing industry, and the stability of 1.0% (15 min) and uniformity of 1.6% are in compliance with the calibration regulation.
topic UV LED
Irradiance source
Integrating sphere
Calibration
url http://www.sciencedirect.com/science/article/pii/S2665917421001161
work_keys_str_mv AT tiechengli developmentandmeasurementofa365nmuvledirradiancesource
AT fangshenglin developmentandmeasurementofa365nmuvledirradiancesource
AT muyaoji developmentandmeasurementofa365nmuvledirradiancesource
AT biyonghuang developmentandmeasurementofa365nmuvledirradiancesource
AT weihaicheng developmentandmeasurementofa365nmuvledirradiancesource
AT leibingshi developmentandmeasurementofa365nmuvledirradiancesource
AT mingxia developmentandmeasurementofa365nmuvledirradiancesource
AT lipingwang developmentandmeasurementofa365nmuvledirradiancesource
_version_ 1716830561126842368