Summary: | Abstract Objective: To investigate the effects of preoperative anxiety relieving on electrophysiological changes in patients undergoing off-pump coronary artery bypass surgery. Methods: A total of 61 patients at ASA III risk group in the age range of 18-65 years were enrolled in the present study. Patients were randomly divided into two groups. Group S (Sedation group) was administered 0.04 mg/kg lorazepam per os (PO) twice before the operation. Group C (control group) was not administered with any anxiolytic premedication. State Trait Anxiety Inventory (STAI-I) and Beck Anxiety Inventory (BAI) were used to evaluate the level of anxiety. Electrocardiography (ECG), pulse oximeter and standard monitoring were performed for each patient. QT and P dispersions in each derivation of all ECGs were calculated. Results: Preoperative STAI-I scores were significantly lower in sedation group compared to the controls. Mean values of QT dispersion measured before induction, at the 1st minute of induction, 30th second of intubation and 4th minute of intubation in sedation group were significantly reduced compared to controls (P=0.024; P=0.027; P=0.001; P=0.033, respectively). The mean values of P dispersion measured before induction, at the 3rd minute of induction, 30th second of intubation and 4th minute of intubation in sedation group were significantly reduced compared to controls (P=0.001; P=0.020; P=0.023; P=0.005, respectively). Conclusion: Elevated anxiety levels in patients undergoing coronary bypass surgery have a negative effect through prolonged QT and P-wave dispersion times. Anxiolytic treatment before surgery may be useful to prevent ventricular and atrial arrhythmias and associated complications through decreasing the QT and P-wave dispersion duration.
|