IN-SITU TEST EXPERIMENTAL RESEARCH ON LEAKAGE OF LARGE DIAMETER PRE-STRESSED CONCRETE CYLINDER PIPE (PCCP)
In recent years, a big number of large diameter pre-stressed concrete cylinder pipe (PCCP) lines have been applied to the Mid-route of the South-to-North Water Transfer Project. However, the leakage problem of PCCP causes annually heavy economic losses to our country. In such a context of situation,...
Main Authors: | , |
---|---|
Format: | Article |
Language: | ces |
Published: |
Czech Technical University, Prague
2016-10-01
|
Series: | Civil Engineering Journal |
Subjects: | |
Online Access: | http://www.civilengineeringjournal.cz/archive/issues/2016/2016_3/3-2016-0012-Final.pdf |
id |
doaj-d3594708dec74cdc8f62cf0cde5ca85e |
---|---|
record_format |
Article |
spelling |
doaj-d3594708dec74cdc8f62cf0cde5ca85e2020-11-24T22:33:37ZcesCzech Technical University, PragueCivil Engineering Journal1805-25762016-10-012016310.14311/CEJ.2016.03.0012 IN-SITU TEST EXPERIMENTAL RESEARCH ON LEAKAGE OF LARGE DIAMETER PRE-STRESSED CONCRETE CYLINDER PIPE (PCCP) Jianjun Luo0Liping Gao1Tunnel and Underground Engineering Research Center of Ministry of Education, Beijing Jiaotong University, Beijing, 1000 44, ChinaTunnel and Underground Engineering Research Center of Ministry of Education, Beijing Jiaotong University, Beijing, 1000 44, ChinaIn recent years, a big number of large diameter pre-stressed concrete cylinder pipe (PCCP) lines have been applied to the Mid-route of the South-to-North Water Transfer Project. However, the leakage problem of PCCP causes annually heavy economic losses to our country. In such a context of situation, how to detect leaks rapidly and precisely after pipes appear cracks in water supply system has great significance. Based on the study and analysis of the characteristic structure of large diameter PCCP, a new leak detection system using fiber Bragg grating sensors, which can capture signals of water pressure change, is proposed. The feasibility, reliability and practicability of the system could be acceptable according to data achieved from in–situ tests. Moreover, the leak detection system can monitor in real-time of dynamic change of water pressure. The equations of the leakage quantity and water pressure have been presented in this paper, which can provide technical guidelines for large diameter PCCP lines maintenance. http://www.civilengineeringjournal.cz/archive/issues/2016/2016_3/3-2016-0012-Final.pdfLarge diameter pre - stressed concrete cylinder pipeLeakageIn-situ-testFiber Bragg Grating |
collection |
DOAJ |
language |
ces |
format |
Article |
sources |
DOAJ |
author |
Jianjun Luo Liping Gao |
spellingShingle |
Jianjun Luo Liping Gao IN-SITU TEST EXPERIMENTAL RESEARCH ON LEAKAGE OF LARGE DIAMETER PRE-STRESSED CONCRETE CYLINDER PIPE (PCCP) Civil Engineering Journal Large diameter pre - stressed concrete cylinder pipe Leakage In-situ-test Fiber Bragg Grating |
author_facet |
Jianjun Luo Liping Gao |
author_sort |
Jianjun Luo |
title |
IN-SITU TEST EXPERIMENTAL RESEARCH ON LEAKAGE OF LARGE DIAMETER PRE-STRESSED CONCRETE CYLINDER PIPE (PCCP) |
title_short |
IN-SITU TEST EXPERIMENTAL RESEARCH ON LEAKAGE OF LARGE DIAMETER PRE-STRESSED CONCRETE CYLINDER PIPE (PCCP) |
title_full |
IN-SITU TEST EXPERIMENTAL RESEARCH ON LEAKAGE OF LARGE DIAMETER PRE-STRESSED CONCRETE CYLINDER PIPE (PCCP) |
title_fullStr |
IN-SITU TEST EXPERIMENTAL RESEARCH ON LEAKAGE OF LARGE DIAMETER PRE-STRESSED CONCRETE CYLINDER PIPE (PCCP) |
title_full_unstemmed |
IN-SITU TEST EXPERIMENTAL RESEARCH ON LEAKAGE OF LARGE DIAMETER PRE-STRESSED CONCRETE CYLINDER PIPE (PCCP) |
title_sort |
in-situ test experimental research on leakage of large diameter pre-stressed concrete cylinder pipe (pccp) |
publisher |
Czech Technical University, Prague |
series |
Civil Engineering Journal |
issn |
1805-2576 |
publishDate |
2016-10-01 |
description |
In recent years, a big number of large diameter pre-stressed concrete cylinder pipe (PCCP) lines have been applied to the Mid-route of the South-to-North Water Transfer Project. However, the leakage problem of PCCP causes annually heavy economic losses to our country. In such a context of situation, how to detect leaks rapidly and precisely after pipes appear cracks in water supply system has great significance. Based on the study and analysis of the characteristic structure of large diameter PCCP, a new leak detection system using fiber Bragg grating sensors, which can capture signals of water pressure change, is proposed. The feasibility, reliability and practicability of the system could be acceptable according to data achieved from in–situ tests. Moreover, the leak detection system can monitor in real-time of dynamic change of water pressure. The equations of the leakage quantity and water pressure have been presented in this paper, which can provide technical guidelines for large diameter PCCP lines maintenance. |
topic |
Large diameter pre - stressed concrete cylinder pipe Leakage In-situ-test Fiber Bragg Grating |
url |
http://www.civilengineeringjournal.cz/archive/issues/2016/2016_3/3-2016-0012-Final.pdf |
work_keys_str_mv |
AT jianjunluo insitutestexperimentalresearchonleakageoflargediameterprestressedconcretecylinderpipepccp AT lipinggao insitutestexperimentalresearchonleakageoflargediameterprestressedconcretecylinderpipepccp |
_version_ |
1725730287584804864 |