A New Framework for Congestion Management with Exact Modeling of Impacting Factors
Congestion in the transmission lines is one of the technical problems that appear particularly in the deregulated environment. The voltage stability issue gets more important because of heavy loading in this environment. The main factor causing instability is the inability of the power system to mee...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Iran University of Science and Technology
2012-12-01
|
Series: | Iranian Journal of Electrical and Electronic Engineering |
Subjects: | |
Online Access: | http://ijeee.iust.ac.ir/browse.php?a_code=A-10-515-4&slc_lang=en&sid=1 |
id |
doaj-d2be725032674757ada1a9e2df7a042a |
---|---|
record_format |
Article |
spelling |
doaj-d2be725032674757ada1a9e2df7a042a2020-11-24T22:54:59ZengIran University of Science and TechnologyIranian Journal of Electrical and Electronic Engineering1735-28272383-38902012-12-0184329340A New Framework for Congestion Management with Exact Modeling of Impacting FactorsM. Heydaripour0A. Akbari Foroud1 Semnan University Semnan University Congestion in the transmission lines is one of the technical problems that appear particularly in the deregulated environment. The voltage stability issue gets more important because of heavy loading in this environment. The main factor causing instability is the inability of the power system to meet the demand for reactive power. This paper presents a new approach for alleviation congestion relieving cost by feeding required reactive power of system in addition to re-dispatching active power of generators and load shedding. Furthermore with considering different static load models in congestion management problem with both thermal and voltage instability criteria, tries to the evaluated congestion management cost become more real, accurate and acceptable. The voltage stability is a dynamic phenomenon but often static tools are used for investigating the stability conditions, so this work offers new method that considers two snapshots after contingency to consider voltage stability phenomena more accurate. This algorithm uses different preventive and corrective actions to improve unsuitable voltage stability margin after contingency. The proposed method is tested on IEEE 24-bus Reliability test system, the simulation results shows the effectiveness of the method.http://ijeee.iust.ac.ir/browse.php?a_code=A-10-515-4&slc_lang=en&sid=1Congestion Management Corrective Actions Preventive Static Load Models Voltage Stability |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
M. Heydaripour A. Akbari Foroud |
spellingShingle |
M. Heydaripour A. Akbari Foroud A New Framework for Congestion Management with Exact Modeling of Impacting Factors Iranian Journal of Electrical and Electronic Engineering Congestion Management Corrective Actions Preventive Static Load Models Voltage Stability |
author_facet |
M. Heydaripour A. Akbari Foroud |
author_sort |
M. Heydaripour |
title |
A New Framework for Congestion Management with Exact Modeling of Impacting Factors |
title_short |
A New Framework for Congestion Management with Exact Modeling of Impacting Factors |
title_full |
A New Framework for Congestion Management with Exact Modeling of Impacting Factors |
title_fullStr |
A New Framework for Congestion Management with Exact Modeling of Impacting Factors |
title_full_unstemmed |
A New Framework for Congestion Management with Exact Modeling of Impacting Factors |
title_sort |
new framework for congestion management with exact modeling of impacting factors |
publisher |
Iran University of Science and Technology |
series |
Iranian Journal of Electrical and Electronic Engineering |
issn |
1735-2827 2383-3890 |
publishDate |
2012-12-01 |
description |
Congestion in the transmission lines is one of the technical problems that appear particularly in the deregulated environment. The voltage stability issue gets more important because of heavy loading in this environment. The main factor causing instability is the inability of the power system to meet the demand for reactive power. This paper presents a new approach for alleviation congestion relieving cost by feeding required reactive power of system in addition to re-dispatching active power of generators and load shedding. Furthermore with considering different static load models in congestion management problem with both thermal and voltage instability criteria, tries to the evaluated congestion management cost become more real, accurate and acceptable. The voltage stability is a dynamic phenomenon but often static tools are used for investigating the stability conditions, so this work offers new method that considers two snapshots after contingency to consider voltage stability phenomena more accurate. This algorithm uses different preventive and corrective actions to improve unsuitable voltage stability margin after contingency. The proposed method is tested on IEEE 24-bus Reliability test system, the simulation results shows the effectiveness of the method. |
topic |
Congestion Management Corrective Actions Preventive Static Load Models Voltage Stability |
url |
http://ijeee.iust.ac.ir/browse.php?a_code=A-10-515-4&slc_lang=en&sid=1 |
work_keys_str_mv |
AT mheydaripour anewframeworkforcongestionmanagementwithexactmodelingofimpactingfactors AT aakbariforoud anewframeworkforcongestionmanagementwithexactmodelingofimpactingfactors AT mheydaripour newframeworkforcongestionmanagementwithexactmodelingofimpactingfactors AT aakbariforoud newframeworkforcongestionmanagementwithexactmodelingofimpactingfactors |
_version_ |
1725658459843592192 |