Effect of Different Composite Restorations on the Cuspal Deflection of Premolars Restored with Different Insertion Techniques- An In vitro Study
Introduction: This study was conducted to assess the effect of different composite materials on the cuspal deflection of premolars restored with bulk placement of resin composite in comparison to horizontal incremental placement and modified tangential incremental placement. Aim: The aim of thi...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
JCDR Research and Publications Private Limited
2017-08-01
|
Series: | Journal of Clinical and Diagnostic Research |
Subjects: | |
Online Access: | https://jcdr.net/articles/PDF/10440/20159_070717_20159_CE[Ra1]_F(RK)_PF1(SY_VT_SS)_PFA(NC_SY_SS).pdf |
id |
doaj-d2af81bcfd5b425ab9ad3ea06b716572 |
---|---|
record_format |
Article |
spelling |
doaj-d2af81bcfd5b425ab9ad3ea06b7165722020-11-25T03:21:22ZengJCDR Research and Publications Private LimitedJournal of Clinical and Diagnostic Research2249-782X0973-709X2017-08-01118ZC67ZC7010.7860/JCDR/2017/20159.10440Effect of Different Composite Restorations on the Cuspal Deflection of Premolars Restored with Different Insertion Techniques- An In vitro StudySAKSHI SINGHAL0ANURAAG GURTU1ANURAG SINGHAL2RASHMI BANSAL3SUMIT MOHAN4Postgraduate Student, Department of Conservative Dentistry and Endodontics, Institute of Dental Sciences, Bareilly, Uttar Pradesh, India.Professor, Department of Conservative Dentistry and Endodontics, Institute of Dental Sciences, Bareilly, Uttar Pradesh, India.Professor, Department of Conservative Dentistry and Endodontics, Institute of Dental Sciences, Bareilly, Uttar Pradesh, India.Professor and Head, Department of Conservative Dentistry and Endodontics, Institute of Dental Sciences, Bareilly, Uttar Pradesh, India.Senior Lecturer, Department of Conservative Dentistry and Endodontics, Institute of Dental Sciences, Bareilly, Uttar Pradesh, India.Introduction: This study was conducted to assess the effect of different composite materials on the cuspal deflection of premolars restored with bulk placement of resin composite in comparison to horizontal incremental placement and modified tangential incremental placement. Aim: The aim of this study was to evaluate the cuspal deflection caused by different composite materials when different insertion techniques were used. Materials and Methods: Two different composite materials were used that is Tetric N Ceram (Ivoclar Vivadent marketing, India) and SonicFillTM (Kerr Sybron Dental). Forty standardized Mesio-Occluso-Distal (MOD) preparations were prepared on maxillary first premolars. Each group was divided according to composite insertion technique (n=10), as follows: Group I – bulk insertion using Tetric N Ceram, Group II - Horizontal incremental insertion technique using Tetric N Ceram, Group III- Modified tangential incremental technique using Tetric N Ceram, and Group IV- bulk insertion using SonicFillTM. Preparations were acid-etched, and bonded with adhesive resin to provide micro mechanical attachment before restoration using a uniform etching and bonding protocol in all the groups. All groups received the same total photo-polymerization time. Cuspal deflection was measured during the restorative procedure using customized digital micrometer assembly. One-way ANOVA test was applied for the analysis of significant difference between the groups, p-value less than 0.05 was considered statistically significant. Results: The average cuspal deflections for the different groups were as follows: Group I 0.045±0.018, Group II 0.029±0.009, Group III 0.018±0.005 and Group IV 0.017±0.004. The intergroup comparison revealed statistically significant difference. Conclusion: A measurable amount of cuspal deflection was present in all the four studied groups. In general, bulkfill restoration technique with conventional composite showed significantly highest cusp deflection. There were no significant differences in cuspal deflection among sonicFillTM and modified tangential incremental insertion techniques.https://jcdr.net/articles/PDF/10440/20159_070717_20159_CE[Ra1]_F(RK)_PF1(SY_VT_SS)_PFA(NC_SY_SS).pdfhorizontal incremental techniquemodified tangential techniquesonicfill |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
SAKSHI SINGHAL ANURAAG GURTU ANURAG SINGHAL RASHMI BANSAL SUMIT MOHAN |
spellingShingle |
SAKSHI SINGHAL ANURAAG GURTU ANURAG SINGHAL RASHMI BANSAL SUMIT MOHAN Effect of Different Composite Restorations on the Cuspal Deflection of Premolars Restored with Different Insertion Techniques- An In vitro Study Journal of Clinical and Diagnostic Research horizontal incremental technique modified tangential technique sonicfill |
author_facet |
SAKSHI SINGHAL ANURAAG GURTU ANURAG SINGHAL RASHMI BANSAL SUMIT MOHAN |
author_sort |
SAKSHI SINGHAL |
title |
Effect of Different Composite Restorations on the Cuspal Deflection of Premolars Restored with Different Insertion Techniques- An In vitro Study |
title_short |
Effect of Different Composite Restorations on the Cuspal Deflection of Premolars Restored with Different Insertion Techniques- An In vitro Study |
title_full |
Effect of Different Composite Restorations on the Cuspal Deflection of Premolars Restored with Different Insertion Techniques- An In vitro Study |
title_fullStr |
Effect of Different Composite Restorations on the Cuspal Deflection of Premolars Restored with Different Insertion Techniques- An In vitro Study |
title_full_unstemmed |
Effect of Different Composite Restorations on the Cuspal Deflection of Premolars Restored with Different Insertion Techniques- An In vitro Study |
title_sort |
effect of different composite restorations on the cuspal deflection of premolars restored with different insertion techniques- an in vitro study |
publisher |
JCDR Research and Publications Private Limited |
series |
Journal of Clinical and Diagnostic Research |
issn |
2249-782X 0973-709X |
publishDate |
2017-08-01 |
description |
Introduction: This study was conducted to assess the effect
of different composite materials on the cuspal deflection of
premolars restored with bulk placement of resin composite in
comparison to horizontal incremental placement and modified
tangential incremental placement.
Aim: The aim of this study was to evaluate the cuspal deflection
caused by different composite materials when different insertion
techniques were used.
Materials and Methods: Two different composite materials
were used that is Tetric N Ceram (Ivoclar Vivadent marketing,
India) and SonicFillTM (Kerr Sybron Dental). Forty standardized
Mesio-Occluso-Distal (MOD) preparations were prepared on
maxillary first premolars. Each group was divided according to
composite insertion technique (n=10), as follows: Group I – bulk
insertion using Tetric N Ceram, Group II - Horizontal incremental
insertion technique using Tetric N Ceram, Group III- Modified
tangential incremental technique using Tetric N Ceram, and
Group IV- bulk insertion using SonicFillTM. Preparations were
acid-etched, and bonded with adhesive resin to provide micro
mechanical attachment before restoration using a uniform
etching and bonding protocol in all the groups. All groups
received the same total photo-polymerization time. Cuspal
deflection was measured during the restorative procedure using
customized digital micrometer assembly. One-way ANOVA test
was applied for the analysis of significant difference between
the groups, p-value less than 0.05 was considered statistically
significant.
Results: The average cuspal deflections for the different groups
were as follows: Group I 0.045±0.018, Group II 0.029±0.009,
Group III 0.018±0.005 and Group IV 0.017±0.004. The intergroup
comparison revealed statistically significant difference.
Conclusion: A measurable amount of cuspal deflection
was present in all the four studied groups. In general, bulkfill
restoration technique with conventional composite showed
significantly highest cusp deflection. There were no significant
differences in cuspal deflection among sonicFillTM and modified
tangential incremental insertion techniques. |
topic |
horizontal incremental technique modified tangential technique sonicfill |
url |
https://jcdr.net/articles/PDF/10440/20159_070717_20159_CE[Ra1]_F(RK)_PF1(SY_VT_SS)_PFA(NC_SY_SS).pdf |
work_keys_str_mv |
AT sakshisinghal effectofdifferentcompositerestorationsonthecuspaldeflectionofpremolarsrestoredwithdifferentinsertiontechniquesaninvitrostudy AT anuraaggurtu effectofdifferentcompositerestorationsonthecuspaldeflectionofpremolarsrestoredwithdifferentinsertiontechniquesaninvitrostudy AT anuragsinghal effectofdifferentcompositerestorationsonthecuspaldeflectionofpremolarsrestoredwithdifferentinsertiontechniquesaninvitrostudy AT rashmibansal effectofdifferentcompositerestorationsonthecuspaldeflectionofpremolarsrestoredwithdifferentinsertiontechniquesaninvitrostudy AT sumitmohan effectofdifferentcompositerestorationsonthecuspaldeflectionofpremolarsrestoredwithdifferentinsertiontechniquesaninvitrostudy |
_version_ |
1724615178545266688 |