Effect of Different Composite Restorations on the Cuspal Deflection of Premolars Restored with Different Insertion Techniques- An In vitro Study

Introduction: This study was conducted to assess the effect of different composite materials on the cuspal deflection of premolars restored with bulk placement of resin composite in comparison to horizontal incremental placement and modified tangential incremental placement. Aim: The aim of thi...

Full description

Bibliographic Details
Main Authors: SAKSHI SINGHAL, ANURAAG GURTU, ANURAG SINGHAL, RASHMI BANSAL, SUMIT MOHAN
Format: Article
Language:English
Published: JCDR Research and Publications Private Limited 2017-08-01
Series:Journal of Clinical and Diagnostic Research
Subjects:
Online Access:https://jcdr.net/articles/PDF/10440/20159_070717_20159_CE[Ra1]_F(RK)_PF1(SY_VT_SS)_PFA(NC_SY_SS).pdf
id doaj-d2af81bcfd5b425ab9ad3ea06b716572
record_format Article
spelling doaj-d2af81bcfd5b425ab9ad3ea06b7165722020-11-25T03:21:22ZengJCDR Research and Publications Private LimitedJournal of Clinical and Diagnostic Research2249-782X0973-709X2017-08-01118ZC67ZC7010.7860/JCDR/2017/20159.10440Effect of Different Composite Restorations on the Cuspal Deflection of Premolars Restored with Different Insertion Techniques- An In vitro StudySAKSHI SINGHAL0ANURAAG GURTU1ANURAG SINGHAL2RASHMI BANSAL3SUMIT MOHAN4Postgraduate Student, Department of Conservative Dentistry and Endodontics, Institute of Dental Sciences, Bareilly, Uttar Pradesh, India.Professor, Department of Conservative Dentistry and Endodontics, Institute of Dental Sciences, Bareilly, Uttar Pradesh, India.Professor, Department of Conservative Dentistry and Endodontics, Institute of Dental Sciences, Bareilly, Uttar Pradesh, India.Professor and Head, Department of Conservative Dentistry and Endodontics, Institute of Dental Sciences, Bareilly, Uttar Pradesh, India.Senior Lecturer, Department of Conservative Dentistry and Endodontics, Institute of Dental Sciences, Bareilly, Uttar Pradesh, India.Introduction: This study was conducted to assess the effect of different composite materials on the cuspal deflection of premolars restored with bulk placement of resin composite in comparison to horizontal incremental placement and modified tangential incremental placement. Aim: The aim of this study was to evaluate the cuspal deflection caused by different composite materials when different insertion techniques were used. Materials and Methods: Two different composite materials were used that is Tetric N Ceram (Ivoclar Vivadent marketing, India) and SonicFillTM (Kerr Sybron Dental). Forty standardized Mesio-Occluso-Distal (MOD) preparations were prepared on maxillary first premolars. Each group was divided according to composite insertion technique (n=10), as follows: Group I – bulk insertion using Tetric N Ceram, Group II - Horizontal incremental insertion technique using Tetric N Ceram, Group III- Modified tangential incremental technique using Tetric N Ceram, and Group IV- bulk insertion using SonicFillTM. Preparations were acid-etched, and bonded with adhesive resin to provide micro mechanical attachment before restoration using a uniform etching and bonding protocol in all the groups. All groups received the same total photo-polymerization time. Cuspal deflection was measured during the restorative procedure using customized digital micrometer assembly. One-way ANOVA test was applied for the analysis of significant difference between the groups, p-value less than 0.05 was considered statistically significant. Results: The average cuspal deflections for the different groups were as follows: Group I 0.045±0.018, Group II 0.029±0.009, Group III 0.018±0.005 and Group IV 0.017±0.004. The intergroup comparison revealed statistically significant difference. Conclusion: A measurable amount of cuspal deflection was present in all the four studied groups. In general, bulkfill restoration technique with conventional composite showed significantly highest cusp deflection. There were no significant differences in cuspal deflection among sonicFillTM and modified tangential incremental insertion techniques.https://jcdr.net/articles/PDF/10440/20159_070717_20159_CE[Ra1]_F(RK)_PF1(SY_VT_SS)_PFA(NC_SY_SS).pdfhorizontal incremental techniquemodified tangential techniquesonicfill
collection DOAJ
language English
format Article
sources DOAJ
author SAKSHI SINGHAL
ANURAAG GURTU
ANURAG SINGHAL
RASHMI BANSAL
SUMIT MOHAN
spellingShingle SAKSHI SINGHAL
ANURAAG GURTU
ANURAG SINGHAL
RASHMI BANSAL
SUMIT MOHAN
Effect of Different Composite Restorations on the Cuspal Deflection of Premolars Restored with Different Insertion Techniques- An In vitro Study
Journal of Clinical and Diagnostic Research
horizontal incremental technique
modified tangential technique
sonicfill
author_facet SAKSHI SINGHAL
ANURAAG GURTU
ANURAG SINGHAL
RASHMI BANSAL
SUMIT MOHAN
author_sort SAKSHI SINGHAL
title Effect of Different Composite Restorations on the Cuspal Deflection of Premolars Restored with Different Insertion Techniques- An In vitro Study
title_short Effect of Different Composite Restorations on the Cuspal Deflection of Premolars Restored with Different Insertion Techniques- An In vitro Study
title_full Effect of Different Composite Restorations on the Cuspal Deflection of Premolars Restored with Different Insertion Techniques- An In vitro Study
title_fullStr Effect of Different Composite Restorations on the Cuspal Deflection of Premolars Restored with Different Insertion Techniques- An In vitro Study
title_full_unstemmed Effect of Different Composite Restorations on the Cuspal Deflection of Premolars Restored with Different Insertion Techniques- An In vitro Study
title_sort effect of different composite restorations on the cuspal deflection of premolars restored with different insertion techniques- an in vitro study
publisher JCDR Research and Publications Private Limited
series Journal of Clinical and Diagnostic Research
issn 2249-782X
0973-709X
publishDate 2017-08-01
description Introduction: This study was conducted to assess the effect of different composite materials on the cuspal deflection of premolars restored with bulk placement of resin composite in comparison to horizontal incremental placement and modified tangential incremental placement. Aim: The aim of this study was to evaluate the cuspal deflection caused by different composite materials when different insertion techniques were used. Materials and Methods: Two different composite materials were used that is Tetric N Ceram (Ivoclar Vivadent marketing, India) and SonicFillTM (Kerr Sybron Dental). Forty standardized Mesio-Occluso-Distal (MOD) preparations were prepared on maxillary first premolars. Each group was divided according to composite insertion technique (n=10), as follows: Group I – bulk insertion using Tetric N Ceram, Group II - Horizontal incremental insertion technique using Tetric N Ceram, Group III- Modified tangential incremental technique using Tetric N Ceram, and Group IV- bulk insertion using SonicFillTM. Preparations were acid-etched, and bonded with adhesive resin to provide micro mechanical attachment before restoration using a uniform etching and bonding protocol in all the groups. All groups received the same total photo-polymerization time. Cuspal deflection was measured during the restorative procedure using customized digital micrometer assembly. One-way ANOVA test was applied for the analysis of significant difference between the groups, p-value less than 0.05 was considered statistically significant. Results: The average cuspal deflections for the different groups were as follows: Group I 0.045±0.018, Group II 0.029±0.009, Group III 0.018±0.005 and Group IV 0.017±0.004. The intergroup comparison revealed statistically significant difference. Conclusion: A measurable amount of cuspal deflection was present in all the four studied groups. In general, bulkfill restoration technique with conventional composite showed significantly highest cusp deflection. There were no significant differences in cuspal deflection among sonicFillTM and modified tangential incremental insertion techniques.
topic horizontal incremental technique
modified tangential technique
sonicfill
url https://jcdr.net/articles/PDF/10440/20159_070717_20159_CE[Ra1]_F(RK)_PF1(SY_VT_SS)_PFA(NC_SY_SS).pdf
work_keys_str_mv AT sakshisinghal effectofdifferentcompositerestorationsonthecuspaldeflectionofpremolarsrestoredwithdifferentinsertiontechniquesaninvitrostudy
AT anuraaggurtu effectofdifferentcompositerestorationsonthecuspaldeflectionofpremolarsrestoredwithdifferentinsertiontechniquesaninvitrostudy
AT anuragsinghal effectofdifferentcompositerestorationsonthecuspaldeflectionofpremolarsrestoredwithdifferentinsertiontechniquesaninvitrostudy
AT rashmibansal effectofdifferentcompositerestorationsonthecuspaldeflectionofpremolarsrestoredwithdifferentinsertiontechniquesaninvitrostudy
AT sumitmohan effectofdifferentcompositerestorationsonthecuspaldeflectionofpremolarsrestoredwithdifferentinsertiontechniquesaninvitrostudy
_version_ 1724615178545266688