Does prewarming of i-gel improve insertion and ventilation in anaesthetised and paralysed patients? A prospective, randomised, control trial

Context: I-gel are supraglottic airway devices with non-inflatable gel-like cuff that is believed to mould to body temperature, to seal the airway. Hence a pre-warmed i-gel may seal faster, provide better ventilation and superior leak pressure. Aims: To determine if pre-warming i-gel to 40°C improve...

Full description

Bibliographic Details
Main Authors: Aamuktha Malyadha Reddy, Nita Varghese, Basavaraj Herekar, Udupi Kailashnath Shenoy
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2019-01-01
Series:Saudi Journal of Anaesthesia
Subjects:
Online Access:http://www.saudija.org/article.asp?issn=1658-354X;year=2019;volume=13;issue=3;spage=215;epage=221;aulast=Reddy
Description
Summary:Context: I-gel are supraglottic airway devices with non-inflatable gel-like cuff that is believed to mould to body temperature, to seal the airway. Hence a pre-warmed i-gel may seal faster, provide better ventilation and superior leak pressure. Aims: To determine if pre-warming i-gel to 40°C improves insertion and efficacy of ventilation. Methods and Materials: A prospective, randomised, controlled trial was done on 64 patients requiring anaesthesia with muscle relaxation for short duration. For those in group W, i-gel warmed to 40°C for 15 minutes before insertion was used, whereas for those in group C, i-gel kept at room temperature (approximately 23°C) was used. The airway sealing pressure over time, number of attempts and time taken for a successful insertion were noted. Statistical Analysis: Mean sealing pressure between two groups was compared using independent sample t-test. Repeated Measures ANOVA was used to analyse mean sealing pressure at 0, 15 and 30 min. P value ≤0.05 was considered statistically significant. Results: Sealing pressure improves over time in both the groups but the mean sealing pressure was higher in group C when compared to group W at all points of time, however this was clinically and statistically insignificant. Ease of insertion, time for successful insertion, insertion attempts, intra-operative manoeuvres were all comparable between the groups with no adverse effects. Conclusions: Pre-warming of i-gel to 40°C does not improve the success rate of insertion or provide a higher sealing pressure in anaesthetised and paralysed patients when compared to i-gel at room temperature.
ISSN:1658-354X