Modeling of germanium detector and its sourceless calibration
The paper describes the procedure of adapting a coaxial high-precision germanium detector to a device with numerical calibration. The procedure includes the determination of detector dimensions and establishing the corresponding model of the system. In order to achieve a successful calibration of th...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
VINCA Institute of Nuclear Sciences
2008-01-01
|
Series: | Nuclear Technology and Radiation Protection |
Subjects: | |
Online Access: | http://www.doiserbia.nb.rs/img/doi/1451-3994/2008/1451-39940802051S.pdf |
id |
doaj-d12bc58064194f21b4d611b48350309d |
---|---|
record_format |
Article |
spelling |
doaj-d12bc58064194f21b4d611b48350309d2020-11-25T00:53:39ZengVINCA Institute of Nuclear SciencesNuclear Technology and Radiation Protection1451-39942008-01-01232515710.2298/NTRP0802051SModeling of germanium detector and its sourceless calibrationSteljić MilijanaMilošević MiodragBeličev PetarThe paper describes the procedure of adapting a coaxial high-precision germanium detector to a device with numerical calibration. The procedure includes the determination of detector dimensions and establishing the corresponding model of the system. In order to achieve a successful calibration of the system without the usage of standard sources, Monte Carlo simulations were performed to determine its efficiency and pulse-height response function. A detailed Monte Carlo model was developed using the MCNP-5.0 code. The obtained results have indicated that this method represents a valuable tool for the quantitative uncertainty analysis of radiation spectrometers and gamma-ray detector calibration, thus minimizing the need for the deployment of radioactive sources. http://www.doiserbia.nb.rs/img/doi/1451-3994/2008/1451-39940802051S.pdfgamma-ray spectrometryHPGe modelingsourceless calibrationMonte Carlo method |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Steljić Milijana Milošević Miodrag Beličev Petar |
spellingShingle |
Steljić Milijana Milošević Miodrag Beličev Petar Modeling of germanium detector and its sourceless calibration Nuclear Technology and Radiation Protection gamma-ray spectrometry HPGe modeling sourceless calibration Monte Carlo method |
author_facet |
Steljić Milijana Milošević Miodrag Beličev Petar |
author_sort |
Steljić Milijana |
title |
Modeling of germanium detector and its sourceless calibration |
title_short |
Modeling of germanium detector and its sourceless calibration |
title_full |
Modeling of germanium detector and its sourceless calibration |
title_fullStr |
Modeling of germanium detector and its sourceless calibration |
title_full_unstemmed |
Modeling of germanium detector and its sourceless calibration |
title_sort |
modeling of germanium detector and its sourceless calibration |
publisher |
VINCA Institute of Nuclear Sciences |
series |
Nuclear Technology and Radiation Protection |
issn |
1451-3994 |
publishDate |
2008-01-01 |
description |
The paper describes the procedure of adapting a coaxial high-precision germanium detector to a device with numerical calibration. The procedure includes the determination of detector dimensions and establishing the corresponding model of the system. In order to achieve a successful calibration of the system without the usage of standard sources, Monte Carlo simulations were performed to determine its efficiency and pulse-height response function. A detailed Monte Carlo model was developed using the MCNP-5.0 code. The obtained results have indicated that this method represents a valuable tool for the quantitative uncertainty analysis of radiation spectrometers and gamma-ray detector calibration, thus minimizing the need for the deployment of radioactive sources. |
topic |
gamma-ray spectrometry HPGe modeling sourceless calibration Monte Carlo method |
url |
http://www.doiserbia.nb.rs/img/doi/1451-3994/2008/1451-39940802051S.pdf |
work_keys_str_mv |