Development and Validation of LC-MS/MS for Analyzing Potential Genotoxic Impurities in Pantoprazole Starting Materials

Pantoprazole sodium (PPZS) is a selective proton pump inhibitor used in the prevention and treatment of gastric acid-related diseases. Six potentially genotoxic impurities (PGIs) are involved in 5-difluoromethoxy-2-mercapto-1H-benzimidazole (DMBZ), which is the starting material of PPZS. To date, no...

Full description

Bibliographic Details
Main Authors: Yuyuan Chen, Song Wu, Qingyun Yang
Format: Article
Language:English
Published: Hindawi Limited 2020-01-01
Series:Journal of Analytical Methods in Chemistry
Online Access:http://dx.doi.org/10.1155/2020/6597363
id doaj-d0ec929b225b46f792fbbe195104146e
record_format Article
spelling doaj-d0ec929b225b46f792fbbe195104146e2020-11-25T02:17:50ZengHindawi LimitedJournal of Analytical Methods in Chemistry2090-88652090-88732020-01-01202010.1155/2020/65973636597363Development and Validation of LC-MS/MS for Analyzing Potential Genotoxic Impurities in Pantoprazole Starting MaterialsYuyuan Chen0Song Wu1Qingyun Yang2Institute of Materia Medica, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100050, ChinaInstitute of Materia Medica, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100050, ChinaInstitute of Materia Medica, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100050, ChinaPantoprazole sodium (PPZS) is a selective proton pump inhibitor used in the prevention and treatment of gastric acid-related diseases. Six potentially genotoxic impurities (PGIs) are involved in 5-difluoromethoxy-2-mercapto-1H-benzimidazole (DMBZ), which is the starting material of PPZS. To date, no suitable method has yet been developed for PGI separation and quantification at the threshold of toxicological concern levels. In this study, a sensitive and reliable liquid chromatography-tandem mass spectrometry method was developed and validated for the quantitative analysis of six PGIs in DMBZ according to the guidelines of the International Council for Harmonization (ICH). The calibration curves showed good linearity within the studied range, and the correlation coefficient of fitting exceeded 0.998 for each impurity. The sensitivity of the proposed method was in the range of 0.6–10.0 ng/mL. Good recoveries were observed in the range of 94.32%–107.43% with RSD values below 6.5%. Quantitative analysis of impurities in substance batches of DMBZ showed the high efficiency of the developed method at a low level. Hence, the proposed method is practical and useful in the detection and qualification of PGIs in DMBZ and may be applied to ensure the safe use of PPZS in clinical treatment.http://dx.doi.org/10.1155/2020/6597363
collection DOAJ
language English
format Article
sources DOAJ
author Yuyuan Chen
Song Wu
Qingyun Yang
spellingShingle Yuyuan Chen
Song Wu
Qingyun Yang
Development and Validation of LC-MS/MS for Analyzing Potential Genotoxic Impurities in Pantoprazole Starting Materials
Journal of Analytical Methods in Chemistry
author_facet Yuyuan Chen
Song Wu
Qingyun Yang
author_sort Yuyuan Chen
title Development and Validation of LC-MS/MS for Analyzing Potential Genotoxic Impurities in Pantoprazole Starting Materials
title_short Development and Validation of LC-MS/MS for Analyzing Potential Genotoxic Impurities in Pantoprazole Starting Materials
title_full Development and Validation of LC-MS/MS for Analyzing Potential Genotoxic Impurities in Pantoprazole Starting Materials
title_fullStr Development and Validation of LC-MS/MS for Analyzing Potential Genotoxic Impurities in Pantoprazole Starting Materials
title_full_unstemmed Development and Validation of LC-MS/MS for Analyzing Potential Genotoxic Impurities in Pantoprazole Starting Materials
title_sort development and validation of lc-ms/ms for analyzing potential genotoxic impurities in pantoprazole starting materials
publisher Hindawi Limited
series Journal of Analytical Methods in Chemistry
issn 2090-8865
2090-8873
publishDate 2020-01-01
description Pantoprazole sodium (PPZS) is a selective proton pump inhibitor used in the prevention and treatment of gastric acid-related diseases. Six potentially genotoxic impurities (PGIs) are involved in 5-difluoromethoxy-2-mercapto-1H-benzimidazole (DMBZ), which is the starting material of PPZS. To date, no suitable method has yet been developed for PGI separation and quantification at the threshold of toxicological concern levels. In this study, a sensitive and reliable liquid chromatography-tandem mass spectrometry method was developed and validated for the quantitative analysis of six PGIs in DMBZ according to the guidelines of the International Council for Harmonization (ICH). The calibration curves showed good linearity within the studied range, and the correlation coefficient of fitting exceeded 0.998 for each impurity. The sensitivity of the proposed method was in the range of 0.6–10.0 ng/mL. Good recoveries were observed in the range of 94.32%–107.43% with RSD values below 6.5%. Quantitative analysis of impurities in substance batches of DMBZ showed the high efficiency of the developed method at a low level. Hence, the proposed method is practical and useful in the detection and qualification of PGIs in DMBZ and may be applied to ensure the safe use of PPZS in clinical treatment.
url http://dx.doi.org/10.1155/2020/6597363
work_keys_str_mv AT yuyuanchen developmentandvalidationoflcmsmsforanalyzingpotentialgenotoxicimpuritiesinpantoprazolestartingmaterials
AT songwu developmentandvalidationoflcmsmsforanalyzingpotentialgenotoxicimpuritiesinpantoprazolestartingmaterials
AT qingyunyang developmentandvalidationoflcmsmsforanalyzingpotentialgenotoxicimpuritiesinpantoprazolestartingmaterials
_version_ 1715521784029118464