Influence and sensitivity analysis of thermal parameters on temperature field distribution of active thermal insulated roadway in high temperature mine

Abstract To study active heat insulation roadway in high temperature mines, the typical high temperature roadway of − 965 m in Zhujidong Coal Mine of Anhui, China, is selected as prototype. The ANSYS numerical simulation method is used for sensitivity analysis of heat insulation layer with different...

Full description

Bibliographic Details
Main Authors: Weijing Yao, Jianyong Pang, Qinyong Ma, Happiness Lyimo
Format: Article
Language:English
Published: SpringerOpen 2020-07-01
Series:International Journal of Coal Science & Technology
Subjects:
Online Access:https://doi.org/10.1007/s40789-020-00343-y
id doaj-d0d6f3ee97c647c7b8ac373027445376
record_format Article
spelling doaj-d0d6f3ee97c647c7b8ac3730274453762021-07-04T11:31:34ZengSpringerOpenInternational Journal of Coal Science & Technology2095-82932198-78232020-07-0181476310.1007/s40789-020-00343-yInfluence and sensitivity analysis of thermal parameters on temperature field distribution of active thermal insulated roadway in high temperature mineWeijing Yao0Jianyong Pang1Qinyong Ma2Happiness Lyimo3School of Civil Engineering and Architecture, Anhui University of Science and TechnologySchool of Civil Engineering and Architecture, Anhui University of Science and TechnologySchool of Civil Engineering and Architecture, Anhui University of Science and TechnologySchool of Civil Engineering and Architecture, Anhui University of Science and TechnologyAbstract To study active heat insulation roadway in high temperature mines, the typical high temperature roadway of − 965 m in Zhujidong Coal Mine of Anhui, China, is selected as prototype. The ANSYS numerical simulation method is used for sensitivity analysis of heat insulation layer with different thermal conductivity and thickness, as well as surrounding rock with different thermal conductivity and temperature on a heat-adjusting zone radius, surrounding rock temperature field and wall temperature. The results show that the heat-adjusting zone radius will entirely be in the right power index relationship to the ventilation time. Decrease in thermal conductivity and increase in thickness of insulation layer can effectively reduce the disturbance of airflow on the surrounding rock temperature, hence, beneficial for decreasing wall temperature. This favourable trend significantly decreases with ventilation time, increase in thermal conductivity and temperature of surrounding rock, heat-adjusting zone radius, surrounding rock temperature field, and wall temperature. Sensitivity analysis shows that the thermal physical properties of surrounding rock determine the temperature distribution of the roadway, hence, temperature of surrounding rock is considered as the most sensitive factor of all influencing factors. For the spray layer, thermal conductivity is more sensitive, compared to thickness. It is concluded that increase in the spray layer thickness is not as beneficial as using low thermal conductivity insulation material. Therefore, roadway preferential consideration should be given to the rocks with low temperature and thermal conductivity. The application of the insulation layer has positive significance for the thermal environment control in mine roadway, however, increase in the layer thickness without restriction has a limited effect on the thermal insulation.https://doi.org/10.1007/s40789-020-00343-yHigh temperature mineActive thermal insulationTemperature field of surrounding rockNumerical simulationSensitivity analysis
collection DOAJ
language English
format Article
sources DOAJ
author Weijing Yao
Jianyong Pang
Qinyong Ma
Happiness Lyimo
spellingShingle Weijing Yao
Jianyong Pang
Qinyong Ma
Happiness Lyimo
Influence and sensitivity analysis of thermal parameters on temperature field distribution of active thermal insulated roadway in high temperature mine
International Journal of Coal Science & Technology
High temperature mine
Active thermal insulation
Temperature field of surrounding rock
Numerical simulation
Sensitivity analysis
author_facet Weijing Yao
Jianyong Pang
Qinyong Ma
Happiness Lyimo
author_sort Weijing Yao
title Influence and sensitivity analysis of thermal parameters on temperature field distribution of active thermal insulated roadway in high temperature mine
title_short Influence and sensitivity analysis of thermal parameters on temperature field distribution of active thermal insulated roadway in high temperature mine
title_full Influence and sensitivity analysis of thermal parameters on temperature field distribution of active thermal insulated roadway in high temperature mine
title_fullStr Influence and sensitivity analysis of thermal parameters on temperature field distribution of active thermal insulated roadway in high temperature mine
title_full_unstemmed Influence and sensitivity analysis of thermal parameters on temperature field distribution of active thermal insulated roadway in high temperature mine
title_sort influence and sensitivity analysis of thermal parameters on temperature field distribution of active thermal insulated roadway in high temperature mine
publisher SpringerOpen
series International Journal of Coal Science & Technology
issn 2095-8293
2198-7823
publishDate 2020-07-01
description Abstract To study active heat insulation roadway in high temperature mines, the typical high temperature roadway of − 965 m in Zhujidong Coal Mine of Anhui, China, is selected as prototype. The ANSYS numerical simulation method is used for sensitivity analysis of heat insulation layer with different thermal conductivity and thickness, as well as surrounding rock with different thermal conductivity and temperature on a heat-adjusting zone radius, surrounding rock temperature field and wall temperature. The results show that the heat-adjusting zone radius will entirely be in the right power index relationship to the ventilation time. Decrease in thermal conductivity and increase in thickness of insulation layer can effectively reduce the disturbance of airflow on the surrounding rock temperature, hence, beneficial for decreasing wall temperature. This favourable trend significantly decreases with ventilation time, increase in thermal conductivity and temperature of surrounding rock, heat-adjusting zone radius, surrounding rock temperature field, and wall temperature. Sensitivity analysis shows that the thermal physical properties of surrounding rock determine the temperature distribution of the roadway, hence, temperature of surrounding rock is considered as the most sensitive factor of all influencing factors. For the spray layer, thermal conductivity is more sensitive, compared to thickness. It is concluded that increase in the spray layer thickness is not as beneficial as using low thermal conductivity insulation material. Therefore, roadway preferential consideration should be given to the rocks with low temperature and thermal conductivity. The application of the insulation layer has positive significance for the thermal environment control in mine roadway, however, increase in the layer thickness without restriction has a limited effect on the thermal insulation.
topic High temperature mine
Active thermal insulation
Temperature field of surrounding rock
Numerical simulation
Sensitivity analysis
url https://doi.org/10.1007/s40789-020-00343-y
work_keys_str_mv AT weijingyao influenceandsensitivityanalysisofthermalparametersontemperaturefielddistributionofactivethermalinsulatedroadwayinhightemperaturemine
AT jianyongpang influenceandsensitivityanalysisofthermalparametersontemperaturefielddistributionofactivethermalinsulatedroadwayinhightemperaturemine
AT qinyongma influenceandsensitivityanalysisofthermalparametersontemperaturefielddistributionofactivethermalinsulatedroadwayinhightemperaturemine
AT happinesslyimo influenceandsensitivityanalysisofthermalparametersontemperaturefielddistributionofactivethermalinsulatedroadwayinhightemperaturemine
_version_ 1721320242937856000