The treatment of early postoperative non-functioning blebs after Ex-PRESS glaucoma drainage device implantation

AIM:To investigate the efficacy and safety of needle revision combined with subconjunctival injection of 5-Fluorouracil(5-FU)for the treatment of early non-functioning blebs after Ex-PRESS glaucoma drainage device implantation.<p>METHODS:The medical records of 18 cases(23 eyes)with non-functio...

Full description

Bibliographic Details
Main Authors: Fang-Gui Liu, Chang-Zheng Chen
Format: Article
Language:English
Published: Press of International Journal of Ophthalmology (IJO PRESS) 2015-10-01
Series:Guoji Yanke Zazhi
Subjects:
Online Access:http://ies.ijo.cn/cn_publish/2015/10/201510042.pdf
id doaj-d0ac9f97352b482794c2908d7f6be2e8
record_format Article
spelling doaj-d0ac9f97352b482794c2908d7f6be2e82020-11-24T22:12:42ZengPress of International Journal of Ophthalmology (IJO PRESS)Guoji Yanke Zazhi1672-51231672-51232015-10-0115101820182210.3980/j.issn.1672-5123.2015.10.42The treatment of early postoperative non-functioning blebs after Ex-PRESS glaucoma drainage device implantationFang-Gui Liu0Chang-Zheng Chen1Ophthalmic Center,Renmin Hospital of Wuhan University, Wuhan 434300, Hubei Province, ChinaOphthalmic Center,Renmin Hospital of Wuhan University, Wuhan 434300, Hubei Province, ChinaAIM:To investigate the efficacy and safety of needle revision combined with subconjunctival injection of 5-Fluorouracil(5-FU)for the treatment of early non-functioning blebs after Ex-PRESS glaucoma drainage device implantation.<p>METHODS:The medical records of 18 cases(23 eyes)with non-functional blebs within postoperative 3mo treated with needle revision combined with subconjunctival injection of 5-FU after Ex-PRESS glaucoma drainage device implantation in our hospital were retrospectively analyzed. All cases were followed up for at least 6mo.The IOP, the changes of filtering blebs morphology before and after treatments and complications were analyzed. <p>RESULTS:The IOP before and immediately, 1, 3, 6mo after treatments were 24.13±2.94, 15.13±4.93, 14.98±5.12, 15.18±3.77 and 15.54±5.07mmHg(1mmHg=0.133kPa)respectively. The IOP at every time point after treatments was significantly decreased compared with that before treatments(all <i>P</i><0.05). The formation rate of functional filter bleb and the total success rate were both 83% at 6mo after treatments. The treatment was failed in 4 eyes(18%). The most common complications were filter bleb subconjunctival hemorrhage and corneal epthelium damage. There were no other severe complications during the follow-up period. <p>CONCLUSION:It is safe, convenient and effective to treat early non-functional blebs after Ex-PRESS glaucoma drainage device implantation by needle revision combined with subconjunctival injection of 5-FU around the filtering bleb.http://ies.ijo.cn/cn_publish/2015/10/201510042.pdfglaucoma drainage implantglaucomafiltering blebneedle revision5-Fluorouracil
collection DOAJ
language English
format Article
sources DOAJ
author Fang-Gui Liu
Chang-Zheng Chen
spellingShingle Fang-Gui Liu
Chang-Zheng Chen
The treatment of early postoperative non-functioning blebs after Ex-PRESS glaucoma drainage device implantation
Guoji Yanke Zazhi
glaucoma drainage implant
glaucoma
filtering bleb
needle revision
5-Fluorouracil
author_facet Fang-Gui Liu
Chang-Zheng Chen
author_sort Fang-Gui Liu
title The treatment of early postoperative non-functioning blebs after Ex-PRESS glaucoma drainage device implantation
title_short The treatment of early postoperative non-functioning blebs after Ex-PRESS glaucoma drainage device implantation
title_full The treatment of early postoperative non-functioning blebs after Ex-PRESS glaucoma drainage device implantation
title_fullStr The treatment of early postoperative non-functioning blebs after Ex-PRESS glaucoma drainage device implantation
title_full_unstemmed The treatment of early postoperative non-functioning blebs after Ex-PRESS glaucoma drainage device implantation
title_sort treatment of early postoperative non-functioning blebs after ex-press glaucoma drainage device implantation
publisher Press of International Journal of Ophthalmology (IJO PRESS)
series Guoji Yanke Zazhi
issn 1672-5123
1672-5123
publishDate 2015-10-01
description AIM:To investigate the efficacy and safety of needle revision combined with subconjunctival injection of 5-Fluorouracil(5-FU)for the treatment of early non-functioning blebs after Ex-PRESS glaucoma drainage device implantation.<p>METHODS:The medical records of 18 cases(23 eyes)with non-functional blebs within postoperative 3mo treated with needle revision combined with subconjunctival injection of 5-FU after Ex-PRESS glaucoma drainage device implantation in our hospital were retrospectively analyzed. All cases were followed up for at least 6mo.The IOP, the changes of filtering blebs morphology before and after treatments and complications were analyzed. <p>RESULTS:The IOP before and immediately, 1, 3, 6mo after treatments were 24.13±2.94, 15.13±4.93, 14.98±5.12, 15.18±3.77 and 15.54±5.07mmHg(1mmHg=0.133kPa)respectively. The IOP at every time point after treatments was significantly decreased compared with that before treatments(all <i>P</i><0.05). The formation rate of functional filter bleb and the total success rate were both 83% at 6mo after treatments. The treatment was failed in 4 eyes(18%). The most common complications were filter bleb subconjunctival hemorrhage and corneal epthelium damage. There were no other severe complications during the follow-up period. <p>CONCLUSION:It is safe, convenient and effective to treat early non-functional blebs after Ex-PRESS glaucoma drainage device implantation by needle revision combined with subconjunctival injection of 5-FU around the filtering bleb.
topic glaucoma drainage implant
glaucoma
filtering bleb
needle revision
5-Fluorouracil
url http://ies.ijo.cn/cn_publish/2015/10/201510042.pdf
work_keys_str_mv AT fangguiliu thetreatmentofearlypostoperativenonfunctioningblebsafterexpressglaucomadrainagedeviceimplantation
AT changzhengchen thetreatmentofearlypostoperativenonfunctioningblebsafterexpressglaucomadrainagedeviceimplantation
AT fangguiliu treatmentofearlypostoperativenonfunctioningblebsafterexpressglaucomadrainagedeviceimplantation
AT changzhengchen treatmentofearlypostoperativenonfunctioningblebsafterexpressglaucomadrainagedeviceimplantation
_version_ 1725802685061398528