Lateral Penumbra Modelling Based Leaf End Shape Optimization for Multileaf Collimator in Radiotherapy

Lateral penumbra of multileaf collimator plays an important role in radiotherapy treatment planning. Growing evidence has revealed that, for a single-focused multileaf collimator, lateral penumbra width is leaf position dependent and largely attributed to the leaf end shape. In our study, an analyti...

Full description

Bibliographic Details
Main Authors: Dong Zhou, Hui Zhang, Peiqing Ye
Format: Article
Language:English
Published: Hindawi Limited 2016-01-01
Series:Computational and Mathematical Methods in Medicine
Online Access:http://dx.doi.org/10.1155/2016/9515794
id doaj-d0a8206b52b74a16af9afb53b7d0bd22
record_format Article
spelling doaj-d0a8206b52b74a16af9afb53b7d0bd222020-11-25T01:33:42ZengHindawi LimitedComputational and Mathematical Methods in Medicine1748-670X1748-67182016-01-01201610.1155/2016/95157949515794Lateral Penumbra Modelling Based Leaf End Shape Optimization for Multileaf Collimator in RadiotherapyDong Zhou0Hui Zhang1Peiqing Ye2Department of Mechanical Engineering, Tsinghua University, Beijing 100084, ChinaDepartment of Mechanical Engineering, Tsinghua University, Beijing 100084, ChinaDepartment of Mechanical Engineering, Tsinghua University, Beijing 100084, ChinaLateral penumbra of multileaf collimator plays an important role in radiotherapy treatment planning. Growing evidence has revealed that, for a single-focused multileaf collimator, lateral penumbra width is leaf position dependent and largely attributed to the leaf end shape. In our study, an analytical method for leaf end induced lateral penumbra modelling is formulated using Tangent Secant Theory. Compared with Monte Carlo simulation and ray tracing algorithm, our model serves well the purpose of cost-efficient penumbra evaluation. Leaf ends represented in parametric forms of circular arc, elliptical arc, Bézier curve, and B-spline are implemented. With biobjective function of penumbra mean and variance introduced, genetic algorithm is carried out for approximating the Pareto frontier. Results show that for circular arc leaf end objective function is convex and convergence to optimal solution is guaranteed using gradient based iterative method. It is found that optimal leaf end in the shape of Bézier curve achieves minimal standard deviation, while using B-spline minimum of penumbra mean is obtained. For treatment modalities in clinical application, optimized leaf ends are in close agreement with actual shapes. Taken together, the method that we propose can provide insight into leaf end shape design of multileaf collimator.http://dx.doi.org/10.1155/2016/9515794
collection DOAJ
language English
format Article
sources DOAJ
author Dong Zhou
Hui Zhang
Peiqing Ye
spellingShingle Dong Zhou
Hui Zhang
Peiqing Ye
Lateral Penumbra Modelling Based Leaf End Shape Optimization for Multileaf Collimator in Radiotherapy
Computational and Mathematical Methods in Medicine
author_facet Dong Zhou
Hui Zhang
Peiqing Ye
author_sort Dong Zhou
title Lateral Penumbra Modelling Based Leaf End Shape Optimization for Multileaf Collimator in Radiotherapy
title_short Lateral Penumbra Modelling Based Leaf End Shape Optimization for Multileaf Collimator in Radiotherapy
title_full Lateral Penumbra Modelling Based Leaf End Shape Optimization for Multileaf Collimator in Radiotherapy
title_fullStr Lateral Penumbra Modelling Based Leaf End Shape Optimization for Multileaf Collimator in Radiotherapy
title_full_unstemmed Lateral Penumbra Modelling Based Leaf End Shape Optimization for Multileaf Collimator in Radiotherapy
title_sort lateral penumbra modelling based leaf end shape optimization for multileaf collimator in radiotherapy
publisher Hindawi Limited
series Computational and Mathematical Methods in Medicine
issn 1748-670X
1748-6718
publishDate 2016-01-01
description Lateral penumbra of multileaf collimator plays an important role in radiotherapy treatment planning. Growing evidence has revealed that, for a single-focused multileaf collimator, lateral penumbra width is leaf position dependent and largely attributed to the leaf end shape. In our study, an analytical method for leaf end induced lateral penumbra modelling is formulated using Tangent Secant Theory. Compared with Monte Carlo simulation and ray tracing algorithm, our model serves well the purpose of cost-efficient penumbra evaluation. Leaf ends represented in parametric forms of circular arc, elliptical arc, Bézier curve, and B-spline are implemented. With biobjective function of penumbra mean and variance introduced, genetic algorithm is carried out for approximating the Pareto frontier. Results show that for circular arc leaf end objective function is convex and convergence to optimal solution is guaranteed using gradient based iterative method. It is found that optimal leaf end in the shape of Bézier curve achieves minimal standard deviation, while using B-spline minimum of penumbra mean is obtained. For treatment modalities in clinical application, optimized leaf ends are in close agreement with actual shapes. Taken together, the method that we propose can provide insight into leaf end shape design of multileaf collimator.
url http://dx.doi.org/10.1155/2016/9515794
work_keys_str_mv AT dongzhou lateralpenumbramodellingbasedleafendshapeoptimizationformultileafcollimatorinradiotherapy
AT huizhang lateralpenumbramodellingbasedleafendshapeoptimizationformultileafcollimatorinradiotherapy
AT peiqingye lateralpenumbramodellingbasedleafendshapeoptimizationformultileafcollimatorinradiotherapy
_version_ 1725076313618776064