Utilizing an auxiliary portable lube oil heating system in Aliabad Katoul-Iran V94.2 gas turbine during standstill mode: a case study

In a gas turbine power plant, the lubrication oil must be hot enough for the turbine start-up where the unit is in standstill mode. Currently, the strategy to heat the lubrication oil of ANSALDO V94.2 gas turbine power plant is operating the units in turning gear mode or interval mode. However, thes...

Full description

Bibliographic Details
Main Authors: H. Hasannejad, Seyyed Masoud Seyyedi, M. Hashemi-Tilehnoee
Format: Article
Language:English
Published: Elsevier 2019-12-01
Series:Propulsion and Power Research
Online Access:http://www.sciencedirect.com/science/article/pii/S2212540X19300537
id doaj-cfc95637d7be4f0da2d5dc2afcff4fda
record_format Article
spelling doaj-cfc95637d7be4f0da2d5dc2afcff4fda2020-11-25T01:12:27ZengElsevierPropulsion and Power Research2212-540X2019-12-0184320328Utilizing an auxiliary portable lube oil heating system in Aliabad Katoul-Iran V94.2 gas turbine during standstill mode: a case studyH. Hasannejad0Seyyed Masoud Seyyedi1M. Hashemi-Tilehnoee2Department of Mechanical Engineering, Aliabad Katoul Branch, Islamic Azad University, Aliabad Katoul, IranDepartment of Mechanical Engineering, Aliabad Katoul Branch, Islamic Azad University, Aliabad Katoul, Iran; Corresponding author.Young Researchers and Elite Club, Aliabad Katoul Branch, Islamic Azad University, Aliabad Katoul, IranIn a gas turbine power plant, the lubrication oil must be hot enough for the turbine start-up where the unit is in standstill mode. Currently, the strategy to heat the lubrication oil of ANSALDO V94.2 gas turbine power plant is operating the units in turning gear mode or interval mode. However, these strategies cause to suffering the power plant from high power consumption rate and aging. In this study, an auxiliary portable heating system was added to the unit 5 of the MAPNA built MGT-70 (an Iranian version of V94.2) Aliabad Katoul-Iran power plant for increasing the lube oil temperature. Irreversibility, cost-effectiveness, and availability of the proposed heating system are studied by the concepts of exergy, economy, and reliability analyses, respectively. The result of the exergy analysis shows that by using the auxiliary portable lube oil heating system the exergy destruction decreases about 94.7% and 92.6% in comparison with turning gear mode and interval mode, respectively. The result of the economic analysis shows that the auxiliary portable heating system consumes less power rather than turning gear mode. Moreover, it is a cost-effective system which has no penalty and no non-profit production. Finally, the reliability analysis shows that the auxiliary portable lube oil heating system is a reliable tool during its lifetime. Keywords: Gas turbine, Lube oil, Lubrication system, Portable heater, Exergy, Reliabilityhttp://www.sciencedirect.com/science/article/pii/S2212540X19300537
collection DOAJ
language English
format Article
sources DOAJ
author H. Hasannejad
Seyyed Masoud Seyyedi
M. Hashemi-Tilehnoee
spellingShingle H. Hasannejad
Seyyed Masoud Seyyedi
M. Hashemi-Tilehnoee
Utilizing an auxiliary portable lube oil heating system in Aliabad Katoul-Iran V94.2 gas turbine during standstill mode: a case study
Propulsion and Power Research
author_facet H. Hasannejad
Seyyed Masoud Seyyedi
M. Hashemi-Tilehnoee
author_sort H. Hasannejad
title Utilizing an auxiliary portable lube oil heating system in Aliabad Katoul-Iran V94.2 gas turbine during standstill mode: a case study
title_short Utilizing an auxiliary portable lube oil heating system in Aliabad Katoul-Iran V94.2 gas turbine during standstill mode: a case study
title_full Utilizing an auxiliary portable lube oil heating system in Aliabad Katoul-Iran V94.2 gas turbine during standstill mode: a case study
title_fullStr Utilizing an auxiliary portable lube oil heating system in Aliabad Katoul-Iran V94.2 gas turbine during standstill mode: a case study
title_full_unstemmed Utilizing an auxiliary portable lube oil heating system in Aliabad Katoul-Iran V94.2 gas turbine during standstill mode: a case study
title_sort utilizing an auxiliary portable lube oil heating system in aliabad katoul-iran v94.2 gas turbine during standstill mode: a case study
publisher Elsevier
series Propulsion and Power Research
issn 2212-540X
publishDate 2019-12-01
description In a gas turbine power plant, the lubrication oil must be hot enough for the turbine start-up where the unit is in standstill mode. Currently, the strategy to heat the lubrication oil of ANSALDO V94.2 gas turbine power plant is operating the units in turning gear mode or interval mode. However, these strategies cause to suffering the power plant from high power consumption rate and aging. In this study, an auxiliary portable heating system was added to the unit 5 of the MAPNA built MGT-70 (an Iranian version of V94.2) Aliabad Katoul-Iran power plant for increasing the lube oil temperature. Irreversibility, cost-effectiveness, and availability of the proposed heating system are studied by the concepts of exergy, economy, and reliability analyses, respectively. The result of the exergy analysis shows that by using the auxiliary portable lube oil heating system the exergy destruction decreases about 94.7% and 92.6% in comparison with turning gear mode and interval mode, respectively. The result of the economic analysis shows that the auxiliary portable heating system consumes less power rather than turning gear mode. Moreover, it is a cost-effective system which has no penalty and no non-profit production. Finally, the reliability analysis shows that the auxiliary portable lube oil heating system is a reliable tool during its lifetime. Keywords: Gas turbine, Lube oil, Lubrication system, Portable heater, Exergy, Reliability
url http://www.sciencedirect.com/science/article/pii/S2212540X19300537
work_keys_str_mv AT hhasannejad utilizinganauxiliaryportablelubeoilheatingsysteminaliabadkatouliranv942gasturbineduringstandstillmodeacasestudy
AT seyyedmasoudseyyedi utilizinganauxiliaryportablelubeoilheatingsysteminaliabadkatouliranv942gasturbineduringstandstillmodeacasestudy
AT mhashemitilehnoee utilizinganauxiliaryportablelubeoilheatingsysteminaliabadkatouliranv942gasturbineduringstandstillmodeacasestudy
_version_ 1725166241701691392