Evaluation of Impact of Some Pulse Parameters on the Efficiency of Electric Cardiac Defibrillation

Objective: to test the hypothesis of the resonance pattern of an electric cardiac defibrillation process and to study the impact of the frequency spectrum of pulses of various shape on the efficiency of defibrillation.Material and methods. The frequency spectrum of pulses the efficiency of which dur...

Full description

Bibliographic Details
Main Authors: I. V. Venin, M. S. Bogushevich, A. I. Redko, S. V. Serikov
Format: Article
Language:Russian
Published: Russian Academy of Medical Sciences 2007-12-01
Series:Obŝaâ Reanimatologiâ
Subjects:
Online Access:https://www.reanimatology.com/rmt/article/view/894
id doaj-cfb3aa00b7b54d9eb808a3a4c5ef576c
record_format Article
spelling doaj-cfb3aa00b7b54d9eb808a3a4c5ef576c2021-07-28T21:21:48ZrusRussian Academy of Medical SciencesObŝaâ Reanimatologiâ1813-97792411-71102007-12-013611411710.15360/1813-9779-2007-6-114-117894Evaluation of Impact of Some Pulse Parameters on the Efficiency of Electric Cardiac DefibrillationI. V. Venin0M. S. Bogushevich1A. I. Redko2S. V. Serikov3METEKOL Research!and!Production Enterprise, Lvov!Nezhin, UkraineResearch Institute of General Reanimatology, Russian Academy of Medical Sciences, MoscowMETEKOL Research!and!Production Enterprise, Lvov!Nezhin, UkraineMETEKOL Research!and!Production Enterprise, Lvov!Nezhin, UkraineObjective: to test the hypothesis of the resonance pattern of an electric cardiac defibrillation process and to study the impact of the frequency spectrum of pulses of various shape on the efficiency of defibrillation.Material and methods. The frequency spectrum of pulses the efficiency of which during defibrillation was known was examined. Delta pulses with a steep anterior and flat posterior front; a pulse with a flat anterior and steep posterior front, a bipolar asymmetric trapezoidal pulse from a DKI-H-15 St BIFASIK+ defibrillator, and its returning pulse were considered. The pulse spectra were calculated and plotted using the Mathematica program (Wolfram Research Inc.).Results. The different pattern of a relationship of the efficiency of defibrillation to the duration of pulses with a damping increment or decrement is shown to be contradictory to the hypothesis of the resonance pattern of an electric cardiac defibrillation process. The pulses with the equal frequency spectrum may have a great efficiency difference during defibrillation. The efficiency may be affected by the pulse phase interval.Conclusion. The value of a spectrum module at the zero frequency of pulse phases may be regarded as one of the parameters characterizing the efficiency and safety of defibrillation exposure.https://www.reanimatology.com/rmt/article/view/894fibrillationdefibrillationresonance processfrequency spectrum
collection DOAJ
language Russian
format Article
sources DOAJ
author I. V. Venin
M. S. Bogushevich
A. I. Redko
S. V. Serikov
spellingShingle I. V. Venin
M. S. Bogushevich
A. I. Redko
S. V. Serikov
Evaluation of Impact of Some Pulse Parameters on the Efficiency of Electric Cardiac Defibrillation
Obŝaâ Reanimatologiâ
fibrillation
defibrillation
resonance process
frequency spectrum
author_facet I. V. Venin
M. S. Bogushevich
A. I. Redko
S. V. Serikov
author_sort I. V. Venin
title Evaluation of Impact of Some Pulse Parameters on the Efficiency of Electric Cardiac Defibrillation
title_short Evaluation of Impact of Some Pulse Parameters on the Efficiency of Electric Cardiac Defibrillation
title_full Evaluation of Impact of Some Pulse Parameters on the Efficiency of Electric Cardiac Defibrillation
title_fullStr Evaluation of Impact of Some Pulse Parameters on the Efficiency of Electric Cardiac Defibrillation
title_full_unstemmed Evaluation of Impact of Some Pulse Parameters on the Efficiency of Electric Cardiac Defibrillation
title_sort evaluation of impact of some pulse parameters on the efficiency of electric cardiac defibrillation
publisher Russian Academy of Medical Sciences
series Obŝaâ Reanimatologiâ
issn 1813-9779
2411-7110
publishDate 2007-12-01
description Objective: to test the hypothesis of the resonance pattern of an electric cardiac defibrillation process and to study the impact of the frequency spectrum of pulses of various shape on the efficiency of defibrillation.Material and methods. The frequency spectrum of pulses the efficiency of which during defibrillation was known was examined. Delta pulses with a steep anterior and flat posterior front; a pulse with a flat anterior and steep posterior front, a bipolar asymmetric trapezoidal pulse from a DKI-H-15 St BIFASIK+ defibrillator, and its returning pulse were considered. The pulse spectra were calculated and plotted using the Mathematica program (Wolfram Research Inc.).Results. The different pattern of a relationship of the efficiency of defibrillation to the duration of pulses with a damping increment or decrement is shown to be contradictory to the hypothesis of the resonance pattern of an electric cardiac defibrillation process. The pulses with the equal frequency spectrum may have a great efficiency difference during defibrillation. The efficiency may be affected by the pulse phase interval.Conclusion. The value of a spectrum module at the zero frequency of pulse phases may be regarded as one of the parameters characterizing the efficiency and safety of defibrillation exposure.
topic fibrillation
defibrillation
resonance process
frequency spectrum
url https://www.reanimatology.com/rmt/article/view/894
work_keys_str_mv AT ivvenin evaluationofimpactofsomepulseparametersontheefficiencyofelectriccardiacdefibrillation
AT msbogushevich evaluationofimpactofsomepulseparametersontheefficiencyofelectriccardiacdefibrillation
AT airedko evaluationofimpactofsomepulseparametersontheefficiencyofelectriccardiacdefibrillation
AT svserikov evaluationofimpactofsomepulseparametersontheefficiencyofelectriccardiacdefibrillation
_version_ 1721260062539776000