A Test Rig for the Experimental Investigation of a MGT/SOFC Hybrid Power Plant Based on a 3kWel Micro Gas Turbine

A hybrid power plant consisting of a micro gas turbine (MGT) and a solid oxide fuel cell (SOFC) is a promising technology to reach the demands for future power plants. DLR aims to set up a MGT/SOFC hybrid power plant demonstrator based on a 3 kWel MTT EnerTwin micro gas turbine and an SOFC module wi...

Full description

Bibliographic Details
Main Authors: Hohloch Martina, Herbst Melanie, Marcellan Anna, Lingstädt Timo, Krummrein Thomas, Aigner Manfred
Format: Article
Language:English
Published: EDP Sciences 2019-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/39/e3sconf_supehr18_02012.pdf
id doaj-cefefabaee61439891331323c6814655
record_format Article
spelling doaj-cefefabaee61439891331323c68146552021-02-02T07:44:54ZengEDP SciencesE3S Web of Conferences2267-12422019-01-011130201210.1051/e3sconf/201911302012e3sconf_supehr18_02012A Test Rig for the Experimental Investigation of a MGT/SOFC Hybrid Power Plant Based on a 3kWel Micro Gas TurbineHohloch Martina0Herbst Melanie1Marcellan Anna2Lingstädt Timo3Krummrein Thomas4Aigner Manfred5Institute of Combustion Technology, German Aerospace Centre (DLR)Institute of Combustion Technology, German Aerospace Centre (DLR)Institute of Combustion Technology, German Aerospace Centre (DLR)Institute of Combustion Technology, German Aerospace Centre (DLR)Institute of Combustion Technology, German Aerospace Centre (DLR)Institute of Combustion Technology, German Aerospace Centre (DLR)A hybrid power plant consisting of a micro gas turbine (MGT) and a solid oxide fuel cell (SOFC) is a promising technology to reach the demands for future power plants. DLR aims to set up a MGT/SOFC hybrid power plant demonstrator based on a 3 kWel MTT EnerTwin micro gas turbine and an SOFC module with an electrical power output of 30 kWel from Sunfire. For the detailed investigation of the subsystems under hybrid conditions two separate test rigs are set up, one in which the MGT is connected to an emulator of the SOFC and vice versa. The paper introduces the set-up and the functionalities of the MGT based test rig. The special features are highlighted and the possibilities of the cyber physical system for emulation of a hybrid system are explained.https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/39/e3sconf_supehr18_02012.pdf
collection DOAJ
language English
format Article
sources DOAJ
author Hohloch Martina
Herbst Melanie
Marcellan Anna
Lingstädt Timo
Krummrein Thomas
Aigner Manfred
spellingShingle Hohloch Martina
Herbst Melanie
Marcellan Anna
Lingstädt Timo
Krummrein Thomas
Aigner Manfred
A Test Rig for the Experimental Investigation of a MGT/SOFC Hybrid Power Plant Based on a 3kWel Micro Gas Turbine
E3S Web of Conferences
author_facet Hohloch Martina
Herbst Melanie
Marcellan Anna
Lingstädt Timo
Krummrein Thomas
Aigner Manfred
author_sort Hohloch Martina
title A Test Rig for the Experimental Investigation of a MGT/SOFC Hybrid Power Plant Based on a 3kWel Micro Gas Turbine
title_short A Test Rig for the Experimental Investigation of a MGT/SOFC Hybrid Power Plant Based on a 3kWel Micro Gas Turbine
title_full A Test Rig for the Experimental Investigation of a MGT/SOFC Hybrid Power Plant Based on a 3kWel Micro Gas Turbine
title_fullStr A Test Rig for the Experimental Investigation of a MGT/SOFC Hybrid Power Plant Based on a 3kWel Micro Gas Turbine
title_full_unstemmed A Test Rig for the Experimental Investigation of a MGT/SOFC Hybrid Power Plant Based on a 3kWel Micro Gas Turbine
title_sort test rig for the experimental investigation of a mgt/sofc hybrid power plant based on a 3kwel micro gas turbine
publisher EDP Sciences
series E3S Web of Conferences
issn 2267-1242
publishDate 2019-01-01
description A hybrid power plant consisting of a micro gas turbine (MGT) and a solid oxide fuel cell (SOFC) is a promising technology to reach the demands for future power plants. DLR aims to set up a MGT/SOFC hybrid power plant demonstrator based on a 3 kWel MTT EnerTwin micro gas turbine and an SOFC module with an electrical power output of 30 kWel from Sunfire. For the detailed investigation of the subsystems under hybrid conditions two separate test rigs are set up, one in which the MGT is connected to an emulator of the SOFC and vice versa. The paper introduces the set-up and the functionalities of the MGT based test rig. The special features are highlighted and the possibilities of the cyber physical system for emulation of a hybrid system are explained.
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/39/e3sconf_supehr18_02012.pdf
work_keys_str_mv AT hohlochmartina atestrigfortheexperimentalinvestigationofamgtsofchybridpowerplantbasedona3kwelmicrogasturbine
AT herbstmelanie atestrigfortheexperimentalinvestigationofamgtsofchybridpowerplantbasedona3kwelmicrogasturbine
AT marcellananna atestrigfortheexperimentalinvestigationofamgtsofchybridpowerplantbasedona3kwelmicrogasturbine
AT lingstadttimo atestrigfortheexperimentalinvestigationofamgtsofchybridpowerplantbasedona3kwelmicrogasturbine
AT krummreinthomas atestrigfortheexperimentalinvestigationofamgtsofchybridpowerplantbasedona3kwelmicrogasturbine
AT aignermanfred atestrigfortheexperimentalinvestigationofamgtsofchybridpowerplantbasedona3kwelmicrogasturbine
AT hohlochmartina testrigfortheexperimentalinvestigationofamgtsofchybridpowerplantbasedona3kwelmicrogasturbine
AT herbstmelanie testrigfortheexperimentalinvestigationofamgtsofchybridpowerplantbasedona3kwelmicrogasturbine
AT marcellananna testrigfortheexperimentalinvestigationofamgtsofchybridpowerplantbasedona3kwelmicrogasturbine
AT lingstadttimo testrigfortheexperimentalinvestigationofamgtsofchybridpowerplantbasedona3kwelmicrogasturbine
AT krummreinthomas testrigfortheexperimentalinvestigationofamgtsofchybridpowerplantbasedona3kwelmicrogasturbine
AT aignermanfred testrigfortheexperimentalinvestigationofamgtsofchybridpowerplantbasedona3kwelmicrogasturbine
_version_ 1724298917456117760