Hardware Methods for Onboard Control of Fluidically Actuated Soft Robots

Soft robots provide significant advantages over their rigid counterparts. These compliant, dexterous devices can navigate delicate environments with ease without damage to themselves or their surroundings. With many degrees of freedom, a single soft robotic actuator can achieve configurations that w...

Full description

Bibliographic Details
Main Authors: Kevin McDonald, Tommaso Ranzani
Format: Article
Language:English
Published: Frontiers Media S.A. 2021-08-01
Series:Frontiers in Robotics and AI
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/frobt.2021.720702/full
id doaj-ced074a19a2b460c85f8bd1565084313
record_format Article
spelling doaj-ced074a19a2b460c85f8bd15650843132021-08-17T07:18:53ZengFrontiers Media S.A.Frontiers in Robotics and AI2296-91442021-08-01810.3389/frobt.2021.720702720702Hardware Methods for Onboard Control of Fluidically Actuated Soft RobotsKevin McDonald0Tommaso Ranzani1Tommaso Ranzani2Morphable Biorobotics Laboratory, Department of Mechanical Engineering, Boston University, Boston, MA, United StatesMorphable Biorobotics Laboratory, Department of Mechanical Engineering, Boston University, Boston, MA, United StatesMorphable Biorobotics Laboratory, Department of Biomedical Engineering, Materials Science and Engineering Division, Boston University, Boston, MA, United StatesSoft robots provide significant advantages over their rigid counterparts. These compliant, dexterous devices can navigate delicate environments with ease without damage to themselves or their surroundings. With many degrees of freedom, a single soft robotic actuator can achieve configurations that would be very challenging to obtain when using a rigid linkage. Because of these qualities, soft robots are well suited for human interaction. While there are many types of soft robot actuation, the most common type is fluidic actuation, where a pressurized fluid is used to inflate the device, causing bending or some other deformation. This affords advantages with regards to size, ease of manufacturing, and power delivery, but can pose issues when it comes to controlling the robot. Any device capable of complex tasks such as navigation requires multiple actuators working together. Traditionally, these have each required their own mechanism outside of the robot to control the pressure within. Beyond the limitations on autonomy that such a benchtop controller induces, the tether of tubing connecting the robot to its controller can increase stiffness, reduce reaction speed, and hinder miniaturization. Recently, a variety of techniques have been used to integrate control hardware into soft fluidic robots. These methods are varied and draw from disciplines including microfluidics, digital logic, and material science. In this review paper, we discuss the state of the art of onboard control hardware for soft fluidic robots with an emphasis on novel valve designs, including an overview of the prevailing techniques, how they differ, and how they compare to each other. We also define metrics to guide our comparison and discussion. Since the uses for soft robots can be so varied, the control system for one robot may very likely be inappropriate for use in another. We therefore wish to give an appreciation for the breadth of options available to soft roboticists today.https://www.frontiersin.org/articles/10.3389/frobt.2021.720702/fullsoft roboticssoft actuatorcontrolsmart fluidsmicrofluicsfluidic actuation
collection DOAJ
language English
format Article
sources DOAJ
author Kevin McDonald
Tommaso Ranzani
Tommaso Ranzani
spellingShingle Kevin McDonald
Tommaso Ranzani
Tommaso Ranzani
Hardware Methods for Onboard Control of Fluidically Actuated Soft Robots
Frontiers in Robotics and AI
soft robotics
soft actuator
control
smart fluids
microfluics
fluidic actuation
author_facet Kevin McDonald
Tommaso Ranzani
Tommaso Ranzani
author_sort Kevin McDonald
title Hardware Methods for Onboard Control of Fluidically Actuated Soft Robots
title_short Hardware Methods for Onboard Control of Fluidically Actuated Soft Robots
title_full Hardware Methods for Onboard Control of Fluidically Actuated Soft Robots
title_fullStr Hardware Methods for Onboard Control of Fluidically Actuated Soft Robots
title_full_unstemmed Hardware Methods for Onboard Control of Fluidically Actuated Soft Robots
title_sort hardware methods for onboard control of fluidically actuated soft robots
publisher Frontiers Media S.A.
series Frontiers in Robotics and AI
issn 2296-9144
publishDate 2021-08-01
description Soft robots provide significant advantages over their rigid counterparts. These compliant, dexterous devices can navigate delicate environments with ease without damage to themselves or their surroundings. With many degrees of freedom, a single soft robotic actuator can achieve configurations that would be very challenging to obtain when using a rigid linkage. Because of these qualities, soft robots are well suited for human interaction. While there are many types of soft robot actuation, the most common type is fluidic actuation, where a pressurized fluid is used to inflate the device, causing bending or some other deformation. This affords advantages with regards to size, ease of manufacturing, and power delivery, but can pose issues when it comes to controlling the robot. Any device capable of complex tasks such as navigation requires multiple actuators working together. Traditionally, these have each required their own mechanism outside of the robot to control the pressure within. Beyond the limitations on autonomy that such a benchtop controller induces, the tether of tubing connecting the robot to its controller can increase stiffness, reduce reaction speed, and hinder miniaturization. Recently, a variety of techniques have been used to integrate control hardware into soft fluidic robots. These methods are varied and draw from disciplines including microfluidics, digital logic, and material science. In this review paper, we discuss the state of the art of onboard control hardware for soft fluidic robots with an emphasis on novel valve designs, including an overview of the prevailing techniques, how they differ, and how they compare to each other. We also define metrics to guide our comparison and discussion. Since the uses for soft robots can be so varied, the control system for one robot may very likely be inappropriate for use in another. We therefore wish to give an appreciation for the breadth of options available to soft roboticists today.
topic soft robotics
soft actuator
control
smart fluids
microfluics
fluidic actuation
url https://www.frontiersin.org/articles/10.3389/frobt.2021.720702/full
work_keys_str_mv AT kevinmcdonald hardwaremethodsforonboardcontroloffluidicallyactuatedsoftrobots
AT tommasoranzani hardwaremethodsforonboardcontroloffluidicallyactuatedsoftrobots
AT tommasoranzani hardwaremethodsforonboardcontroloffluidicallyactuatedsoftrobots
_version_ 1721205377206321152