Experimental Study of Harmonic Influence on Electrical Energy Metering

The paper considers the influence of harmonics on the operating of electrical energy meters in a network with nonlinear loads. It is shown that electronic static meters of active energy are tested in the presence of distortions, and electronic static meters of reactive energy accuracy requirements d...

Full description

Bibliographic Details
Main Authors: Yaroslav Shklyarskiy, Zbigniew Hanzelka, Aleksandr Skamyin
Format: Article
Language:English
Published: MDPI AG 2020-10-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/13/21/5536
id doaj-cece5bbdbe7c482dafcebf36c1948e66
record_format Article
spelling doaj-cece5bbdbe7c482dafcebf36c1948e662020-11-25T03:59:03ZengMDPI AGEnergies1996-10732020-10-01135536553610.3390/en13215536Experimental Study of Harmonic Influence on Electrical Energy MeteringYaroslav Shklyarskiy0Zbigniew Hanzelka1Aleksandr Skamyin2Department of General Electrical Engineering, Saint-Petersburg Mining University, 199106 Saint-Petersburg, RussiaFaculty of Electrical Engineering, Automatics, Computer Science and Biomedical Engineering, AGH University of Science and Technology, 30-059 Krakow, PolandDepartment of Electric Power and Electromechanics, Saint-Petersburg Mining University, 199106 Saint-Petersburg, RussiaThe paper considers the influence of harmonics on the operating of electrical energy meters in a network with nonlinear loads. It is shown that electronic static meters of active energy are tested in the presence of distortions, and electronic static meters of reactive energy accuracy requirements do not take into account the possible presence of harmonics. It is revealed that the maximum influence on the error in active energy metering is exerted by the number of harmonics taken into account and their amplitude, and the error in reactive energy metering is additionally influenced by the phase angle at the fundamental and harmonic frequencies, which has been confirmed in laboratory conditions. Additionally, experimental studies of the capacitor bank’s influence on reactive energy metering has been carried out in the presence of nonlinear electrical loads. It is shown that when capacitor banks are connected, the error in reactive energy measurement and variation range of the phase shift angle of harmonics significantly increases. The assessment of the computational error of reactive power metering according to various equations were carried out based on the field measurements. If the voltage and current distortion values do not exceed the permissible values, the error can be estimated at, at most, 5–7%.https://www.mdpi.com/1996-1073/13/21/5536high harmonicstotal harmonic distortionpower qualityelectrical energy meterscapacitor banksactive energy
collection DOAJ
language English
format Article
sources DOAJ
author Yaroslav Shklyarskiy
Zbigniew Hanzelka
Aleksandr Skamyin
spellingShingle Yaroslav Shklyarskiy
Zbigniew Hanzelka
Aleksandr Skamyin
Experimental Study of Harmonic Influence on Electrical Energy Metering
Energies
high harmonics
total harmonic distortion
power quality
electrical energy meters
capacitor banks
active energy
author_facet Yaroslav Shklyarskiy
Zbigniew Hanzelka
Aleksandr Skamyin
author_sort Yaroslav Shklyarskiy
title Experimental Study of Harmonic Influence on Electrical Energy Metering
title_short Experimental Study of Harmonic Influence on Electrical Energy Metering
title_full Experimental Study of Harmonic Influence on Electrical Energy Metering
title_fullStr Experimental Study of Harmonic Influence on Electrical Energy Metering
title_full_unstemmed Experimental Study of Harmonic Influence on Electrical Energy Metering
title_sort experimental study of harmonic influence on electrical energy metering
publisher MDPI AG
series Energies
issn 1996-1073
publishDate 2020-10-01
description The paper considers the influence of harmonics on the operating of electrical energy meters in a network with nonlinear loads. It is shown that electronic static meters of active energy are tested in the presence of distortions, and electronic static meters of reactive energy accuracy requirements do not take into account the possible presence of harmonics. It is revealed that the maximum influence on the error in active energy metering is exerted by the number of harmonics taken into account and their amplitude, and the error in reactive energy metering is additionally influenced by the phase angle at the fundamental and harmonic frequencies, which has been confirmed in laboratory conditions. Additionally, experimental studies of the capacitor bank’s influence on reactive energy metering has been carried out in the presence of nonlinear electrical loads. It is shown that when capacitor banks are connected, the error in reactive energy measurement and variation range of the phase shift angle of harmonics significantly increases. The assessment of the computational error of reactive power metering according to various equations were carried out based on the field measurements. If the voltage and current distortion values do not exceed the permissible values, the error can be estimated at, at most, 5–7%.
topic high harmonics
total harmonic distortion
power quality
electrical energy meters
capacitor banks
active energy
url https://www.mdpi.com/1996-1073/13/21/5536
work_keys_str_mv AT yaroslavshklyarskiy experimentalstudyofharmonicinfluenceonelectricalenergymetering
AT zbigniewhanzelka experimentalstudyofharmonicinfluenceonelectricalenergymetering
AT aleksandrskamyin experimentalstudyofharmonicinfluenceonelectricalenergymetering
_version_ 1724455862993420288