Retinal pigment epithelium condition after laser and ultrasound phacofragmentation. Electron microscopy in experiment. Report 1

ABSTRACT Purpose. To perform a comparative evaluation of a macular retinal pigment epithelium condition after laser and ultrasound phacofragmentations in experiment. Material and method. Electron microscopy of macular retinal pigment epithelium was conducted in 3 cadaver eyes after...

Full description

Bibliographic Details
Main Authors: S.Y. Kopayev, V.G. Kopayeva, S.A. Borsenok, V.U. Alborova
Format: Article
Language:Russian
Published: Publishing house "Ophthalmology" 2013-04-01
Series:Офтальмохирургия
Subjects:
Online Access:http://www.eyepress.ru/article.aspx?12978
id doaj-ce818457467e4676b8e6fb027703b6eb
record_format Article
spelling doaj-ce818457467e4676b8e6fb027703b6eb2020-11-25T00:45:52ZrusPublishing house "Ophthalmology"Офтальмохирургия0235-41600235-41602013-04-0141619Retinal pigment epithelium condition after laser and ultrasound phacofragmentation. Electron microscopy in experiment. Report 1S.Y. Kopayev0V.G. Kopayeva1S.A. Borsenok,2V.U. Alborova3The S. Fyodorov Eye Microsurgery Federal State Institution, Moscow, RussiaThe S. Fyodorov Eye Microsurgery Federal State Institution, Moscow, RussiaThe S. Fyodorov Eye Microsurgery Federal State Institution, Moscow, RussiaThe S. Fyodorov Eye Microsurgery Federal State Institution, Moscow, Russia ABSTRACT Purpose. To perform a comparative evaluation of a macular retinal pigment epithelium condition after laser and ultrasound phacofragmentations in experiment. Material and method. Electron microscopy of macular retinal pigment epithelium was conducted in 3 cadaver eyes after the laser (Nd:YAG 1.44μm) phacofragmentation using the Russian device «RAKOT» and in 3 fellow eyes – after the ultrasound phacoemulsification using Millenium phacomachine. Results. After the laser phacofragmentation the ultra-structure of pigment retinal epithelium in macular area corresponded to the norm. After the ultrasound phacoemulsification some disturbances were noted in the ultra-structural organization of retinal pigment epithelium cells manifested in a rarefaction of the electron optical density of the cell cytoplasm, in an increase of vacuoles. Conclusion. Laser energy is safer for the posterior segment of the eye than ultrasound energy used in the cataract surgery. http://www.eyepress.ru/article.aspx?12978retinal pigment epitheliumphacoemulsificationlaser phacofragmentationRussian laser device «Rakot» (Nd:YAG 1.44 μm)
collection DOAJ
language Russian
format Article
sources DOAJ
author S.Y. Kopayev
V.G. Kopayeva
S.A. Borsenok,
V.U. Alborova
spellingShingle S.Y. Kopayev
V.G. Kopayeva
S.A. Borsenok,
V.U. Alborova
Retinal pigment epithelium condition after laser and ultrasound phacofragmentation. Electron microscopy in experiment. Report 1
Офтальмохирургия
retinal pigment epithelium
phacoemulsification
laser phacofragmentation
Russian laser device «Rakot» (Nd:YAG 1.44 μm)
author_facet S.Y. Kopayev
V.G. Kopayeva
S.A. Borsenok,
V.U. Alborova
author_sort S.Y. Kopayev
title Retinal pigment epithelium condition after laser and ultrasound phacofragmentation. Electron microscopy in experiment. Report 1
title_short Retinal pigment epithelium condition after laser and ultrasound phacofragmentation. Electron microscopy in experiment. Report 1
title_full Retinal pigment epithelium condition after laser and ultrasound phacofragmentation. Electron microscopy in experiment. Report 1
title_fullStr Retinal pigment epithelium condition after laser and ultrasound phacofragmentation. Electron microscopy in experiment. Report 1
title_full_unstemmed Retinal pigment epithelium condition after laser and ultrasound phacofragmentation. Electron microscopy in experiment. Report 1
title_sort retinal pigment epithelium condition after laser and ultrasound phacofragmentation. electron microscopy in experiment. report 1
publisher Publishing house "Ophthalmology"
series Офтальмохирургия
issn 0235-4160
0235-4160
publishDate 2013-04-01
description ABSTRACT Purpose. To perform a comparative evaluation of a macular retinal pigment epithelium condition after laser and ultrasound phacofragmentations in experiment. Material and method. Electron microscopy of macular retinal pigment epithelium was conducted in 3 cadaver eyes after the laser (Nd:YAG 1.44μm) phacofragmentation using the Russian device «RAKOT» and in 3 fellow eyes – after the ultrasound phacoemulsification using Millenium phacomachine. Results. After the laser phacofragmentation the ultra-structure of pigment retinal epithelium in macular area corresponded to the norm. After the ultrasound phacoemulsification some disturbances were noted in the ultra-structural organization of retinal pigment epithelium cells manifested in a rarefaction of the electron optical density of the cell cytoplasm, in an increase of vacuoles. Conclusion. Laser energy is safer for the posterior segment of the eye than ultrasound energy used in the cataract surgery.
topic retinal pigment epithelium
phacoemulsification
laser phacofragmentation
Russian laser device «Rakot» (Nd:YAG 1.44 μm)
url http://www.eyepress.ru/article.aspx?12978
work_keys_str_mv AT sykopayev retinalpigmentepitheliumconditionafterlaserandultrasoundphacofragmentationelectronmicroscopyinexperimentreport1
AT vgkopayeva retinalpigmentepitheliumconditionafterlaserandultrasoundphacofragmentationelectronmicroscopyinexperimentreport1
AT saborsenok retinalpigmentepitheliumconditionafterlaserandultrasoundphacofragmentationelectronmicroscopyinexperimentreport1
AT vualborova retinalpigmentepitheliumconditionafterlaserandultrasoundphacofragmentationelectronmicroscopyinexperimentreport1
_version_ 1725268391346831360