Non-destructive analysis of drug content in polymer coatings with Raman spectroscopy

The analysis of device drug content typically is carried out by means of chromatographic methods such as high performance liquid chromatography (HPLC) or liquid chromatography-mass spectrometry (LCMS). These approved methods are particularly fast, cost-efficient and ubiquitous in chemical-analytical...

Full description

Bibliographic Details
Main Authors: Reske Thomas, Wulf Katharina, Eickner Thomas, Grabow Niels, Schmitz Klaus-Peter, Siewert Stefan
Format: Article
Language:English
Published: De Gruyter 2019-09-01
Series:Current Directions in Biomedical Engineering
Subjects:
Online Access:https://doi.org/10.1515/cdbme-2019-0118
id doaj-ce39b6252c0c461b8ed9f74c166e98c0
record_format Article
spelling doaj-ce39b6252c0c461b8ed9f74c166e98c02021-07-01T05:21:50ZengDe GruyterCurrent Directions in Biomedical Engineering2364-55042019-09-015146947110.1515/cdbme-2019-0118cdbme-2019-0118Non-destructive analysis of drug content in polymer coatings with Raman spectroscopyReske Thomas0Wulf Katharina1Eickner Thomas2Grabow Niels3Schmitz Klaus-Peter4Siewert Stefan5Institute for Implant Technology and Biomaterials e.V., Friedrich-Barnewitz-Str. 4, Rostock-Warnemünde, GermanyInstitute for Biomedical Engineering, Rostock University Medical Center, Rostock-Warnemünde, GermanyInstitute for Biomedical Engineering, Rostock University Medical Center, Rostock-Warnemünde, GermanyInstitute for Biomedical Engineering, Rostock University Medical Center, Rostock-Warnemünde, GermanyInstitute for Biomedical Engineering, Rostock University Medical Center, Rostock-Warnemünde, GermanyInstitute for Implant Technology and Biomaterials e.V., Rostock-Warnemünde, GermanyThe analysis of device drug content typically is carried out by means of chromatographic methods such as high performance liquid chromatography (HPLC) or liquid chromatography-mass spectrometry (LCMS). These approved methods are particularly fast, cost-efficient and ubiquitous in chemical-analytical laboratories. However, these quantitative methods necessitate the drug being eluted, which represents a destructive process. A novel alternative to these well-established methods [1, 2] is the Raman spectroscopy, which is fast and cost-efficient, as well [3]. Additionally, it offers the advantage of nondestructive analysis without the need for a special sample preparation. Within the current investigation we applied Raman spectroscopy for the qualitative and quantitative analysis of dexamethasone (DMS), a glucocorticoid, incorporated in a silicone matrix. The investigation was conducted in a rectangular area on the sample surface. The required number of measuring points (spectra) was determined. Calibration was performed with samples containing different amounts of DMS. The evaluation of Raman spectra is based on the analysis of the peak areas of the bands at 795 rel. cm-1(silicone) and 1,663 rel. cm-1(DMS). Remarkably, next to a precise overview of DMS distribution, an exact and reproducible quantification of incorporated DMS could be obtained.https://doi.org/10.1515/cdbme-2019-0118raman spectroscopydrug contentmethod optimizing
collection DOAJ
language English
format Article
sources DOAJ
author Reske Thomas
Wulf Katharina
Eickner Thomas
Grabow Niels
Schmitz Klaus-Peter
Siewert Stefan
spellingShingle Reske Thomas
Wulf Katharina
Eickner Thomas
Grabow Niels
Schmitz Klaus-Peter
Siewert Stefan
Non-destructive analysis of drug content in polymer coatings with Raman spectroscopy
Current Directions in Biomedical Engineering
raman spectroscopy
drug content
method optimizing
author_facet Reske Thomas
Wulf Katharina
Eickner Thomas
Grabow Niels
Schmitz Klaus-Peter
Siewert Stefan
author_sort Reske Thomas
title Non-destructive analysis of drug content in polymer coatings with Raman spectroscopy
title_short Non-destructive analysis of drug content in polymer coatings with Raman spectroscopy
title_full Non-destructive analysis of drug content in polymer coatings with Raman spectroscopy
title_fullStr Non-destructive analysis of drug content in polymer coatings with Raman spectroscopy
title_full_unstemmed Non-destructive analysis of drug content in polymer coatings with Raman spectroscopy
title_sort non-destructive analysis of drug content in polymer coatings with raman spectroscopy
publisher De Gruyter
series Current Directions in Biomedical Engineering
issn 2364-5504
publishDate 2019-09-01
description The analysis of device drug content typically is carried out by means of chromatographic methods such as high performance liquid chromatography (HPLC) or liquid chromatography-mass spectrometry (LCMS). These approved methods are particularly fast, cost-efficient and ubiquitous in chemical-analytical laboratories. However, these quantitative methods necessitate the drug being eluted, which represents a destructive process. A novel alternative to these well-established methods [1, 2] is the Raman spectroscopy, which is fast and cost-efficient, as well [3]. Additionally, it offers the advantage of nondestructive analysis without the need for a special sample preparation. Within the current investigation we applied Raman spectroscopy for the qualitative and quantitative analysis of dexamethasone (DMS), a glucocorticoid, incorporated in a silicone matrix. The investigation was conducted in a rectangular area on the sample surface. The required number of measuring points (spectra) was determined. Calibration was performed with samples containing different amounts of DMS. The evaluation of Raman spectra is based on the analysis of the peak areas of the bands at 795 rel. cm-1(silicone) and 1,663 rel. cm-1(DMS). Remarkably, next to a precise overview of DMS distribution, an exact and reproducible quantification of incorporated DMS could be obtained.
topic raman spectroscopy
drug content
method optimizing
url https://doi.org/10.1515/cdbme-2019-0118
work_keys_str_mv AT reskethomas nondestructiveanalysisofdrugcontentinpolymercoatingswithramanspectroscopy
AT wulfkatharina nondestructiveanalysisofdrugcontentinpolymercoatingswithramanspectroscopy
AT eicknerthomas nondestructiveanalysisofdrugcontentinpolymercoatingswithramanspectroscopy
AT grabowniels nondestructiveanalysisofdrugcontentinpolymercoatingswithramanspectroscopy
AT schmitzklauspeter nondestructiveanalysisofdrugcontentinpolymercoatingswithramanspectroscopy
AT siewertstefan nondestructiveanalysisofdrugcontentinpolymercoatingswithramanspectroscopy
_version_ 1721347327595118592