Expedited method of testing and refinement of refrigeration centrifugal compressors

Currently existing regulatory documents assume that refrigeration compressors are tested as part of test rigs with heat-exchange equipment. Given the high energy intensity of centrifugal compressors, the drive power of which in cooling mode with a cold capacity of up to 8.0 MW can be 2.0 or more MW,...

Full description

Bibliographic Details
Main Authors: Sukhomlinov Igor, Golovin Mihail
Format: Article
Language:English
Published: EDP Sciences 2019-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/66/e3sconf_eece18_06004.pdf
id doaj-ce295aa004e94abb890d920c08b4824e
record_format Article
spelling doaj-ce295aa004e94abb890d920c08b4824e2021-02-02T06:54:44ZengEDP SciencesE3S Web of Conferences2267-12422019-01-011400600410.1051/e3sconf/201914006004e3sconf_eece18_06004Expedited method of testing and refinement of refrigeration centrifugal compressorsSukhomlinov Igor0Golovin Mihail1JSC “VNIIKHOLODMASH”JSC “VNIIKHOLODMASH”Currently existing regulatory documents assume that refrigeration compressors are tested as part of test rigs with heat-exchange equipment. Given the high energy intensity of centrifugal compressors, the drive power of which in cooling mode with a cold capacity of up to 8.0 MW can be 2.0 or more MW, the creation of test rigs for preliminary and acceptance tests at the manufacturer’s factory requires a large investment. An alternative to the considered refrigeration centrifugal compressors test method is a test on a test rig in which the agent is partially condensed. In this case, an evaporator and a full-sized condenser are not required. The mathematical model of the refrigeration centrifugal compressors developed by JSC VNIIKHOLODMASH, allows testing of the refrigeration centrifugal compressors in model conditions, when the entire compressor operation cycle at the test rig is carried out in the area of superheated steam. Since the refrigeration centrifugal compressors mathematical model is based on physical simulation of compression processes in model stages at different values of conditional Mach numbers, dimensionless characteristics of model stages can be used to calculate the characteristic of the created compressor when operating under new conditions. The implementation of the model test method provides reduction of testing time due to absence of phase changes of the agent, improves the accuracy of the obtained results, reduces of power consumption, simplifies the test rig, and reduces consumption of the agent for filling the rig and water for cooling the agent.https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/66/e3sconf_eece18_06004.pdf
collection DOAJ
language English
format Article
sources DOAJ
author Sukhomlinov Igor
Golovin Mihail
spellingShingle Sukhomlinov Igor
Golovin Mihail
Expedited method of testing and refinement of refrigeration centrifugal compressors
E3S Web of Conferences
author_facet Sukhomlinov Igor
Golovin Mihail
author_sort Sukhomlinov Igor
title Expedited method of testing and refinement of refrigeration centrifugal compressors
title_short Expedited method of testing and refinement of refrigeration centrifugal compressors
title_full Expedited method of testing and refinement of refrigeration centrifugal compressors
title_fullStr Expedited method of testing and refinement of refrigeration centrifugal compressors
title_full_unstemmed Expedited method of testing and refinement of refrigeration centrifugal compressors
title_sort expedited method of testing and refinement of refrigeration centrifugal compressors
publisher EDP Sciences
series E3S Web of Conferences
issn 2267-1242
publishDate 2019-01-01
description Currently existing regulatory documents assume that refrigeration compressors are tested as part of test rigs with heat-exchange equipment. Given the high energy intensity of centrifugal compressors, the drive power of which in cooling mode with a cold capacity of up to 8.0 MW can be 2.0 or more MW, the creation of test rigs for preliminary and acceptance tests at the manufacturer’s factory requires a large investment. An alternative to the considered refrigeration centrifugal compressors test method is a test on a test rig in which the agent is partially condensed. In this case, an evaporator and a full-sized condenser are not required. The mathematical model of the refrigeration centrifugal compressors developed by JSC VNIIKHOLODMASH, allows testing of the refrigeration centrifugal compressors in model conditions, when the entire compressor operation cycle at the test rig is carried out in the area of superheated steam. Since the refrigeration centrifugal compressors mathematical model is based on physical simulation of compression processes in model stages at different values of conditional Mach numbers, dimensionless characteristics of model stages can be used to calculate the characteristic of the created compressor when operating under new conditions. The implementation of the model test method provides reduction of testing time due to absence of phase changes of the agent, improves the accuracy of the obtained results, reduces of power consumption, simplifies the test rig, and reduces consumption of the agent for filling the rig and water for cooling the agent.
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/66/e3sconf_eece18_06004.pdf
work_keys_str_mv AT sukhomlinovigor expeditedmethodoftestingandrefinementofrefrigerationcentrifugalcompressors
AT golovinmihail expeditedmethodoftestingandrefinementofrefrigerationcentrifugalcompressors
_version_ 1724300457520660480