Determination of Organic Solvent in Radioactive Tracer [18F]PBR06 Injection by Cold-on-Column Inlet Gas Chromatography

To develop a quality control inspection method for determining content of ethanol and residual solvent in radiolabeled tracer [18F]PBR06 injection which is used for positron emission tomography imaging. Stabilwax CG column (30 m×0.52 mm, 1 μm) is selected. Temperature program: set initial temperatur...

Full description

Bibliographic Details
Main Author: QIAO Hongwen;SHENG Linghui;LIANG Zhigang
Format: Article
Language:zho
Published: Editorial Board of Journal of Isotopes 2021-06-01
Series:Journal of Isotopes
Subjects:
Online Access:http://www.tws.org.cn/CN/10.7538/tws.2021.34.03.0288
id doaj-cd8c8199dde64a7484c06ff85b346ce9
record_format Article
spelling doaj-cd8c8199dde64a7484c06ff85b346ce92021-08-11T07:41:56ZzhoEditorial Board of Journal of IsotopesJournal of Isotopes1000-75121000-75122021-06-0134328829410.7538/tws.2021.34.03.0288Determination of Organic Solvent in Radioactive Tracer [18F]PBR06 Injection by Cold-on-Column Inlet Gas ChromatographyQIAO Hongwen;SHENG Linghui;LIANG Zhigang0Nuclear Medicine Department of Xuanwu Hospital Capital Medical University, Beijing 100053, China; National Clinical Research Center for Geriatric Diseases of Xuanwu Hospital Capital Medical University, Beijing 100053, China;Information Center, Xuanwu Hospital Capital Medical University, Beijing 100053, ChinaTo develop a quality control inspection method for determining content of ethanol and residual solvent in radiolabeled tracer [18F]PBR06 injection which is used for positron emission tomography imaging. Stabilwax CG column (30 m×0.52 mm, 1 μm) is selected. Temperature program: set initial temperature at 55 ℃, kept for 4 min, then increased to 200 ℃ at rate of 40 ℃/min, hold for 3 min. Hydrogen flame ionization detector is used and the temperature is 240 ℃. The carrier gas is high-purity nitrogen, and the inlet pressure is 5.5 psi (37.9 kPa). The temperature of Cold-on-Column inlet follows the column temperature. The results show that ethanol, acetonitrile, and DMSO have good linear relationships in the concentration range of 0.5%-12.0% (v·v-1), 0.004 0%-0.048 0% (g·g-1) and 0.025%-0.590% (g·g-1). The limit of quantification (S/N=10) for ethanol, acetonitrile, and DMSO is 0.15% (v·v-1), 0.002 9% (g·g-1) and 0.008 2% (g·g-1). The limits of detection (S/N=3) is 0.05% (v·v-1), 0.000 87% (g·g-1) and 0.002 5% (g·g-1), respectively. The results of the standard addition recovery show that the method has good accuracy. The Cold-on-Column inlet GC method developed in this study is suitable for inspecting the content of ethanol, acetonitrile and DMSO in [18F]PBR06 injection. The results of the method validation meet the requirements of the Chinese Pharmacopoeia 2020 edition. The method is accurate and time-saving, requiring only a small volume of sample, which is beneficial to improve the efficiency of product quality control inspection. http://www.tws.org.cn/CN/10.7538/tws.2021.34.03.0288cold-on-column inletgas chromatographypet imaging tracer[18f]pbr06residual solvent
collection DOAJ
language zho
format Article
sources DOAJ
author QIAO Hongwen;SHENG Linghui;LIANG Zhigang
spellingShingle QIAO Hongwen;SHENG Linghui;LIANG Zhigang
Determination of Organic Solvent in Radioactive Tracer [18F]PBR06 Injection by Cold-on-Column Inlet Gas Chromatography
Journal of Isotopes
cold-on-column inlet
gas chromatography
pet imaging tracer
[18f]pbr06
residual solvent
author_facet QIAO Hongwen;SHENG Linghui;LIANG Zhigang
author_sort QIAO Hongwen;SHENG Linghui;LIANG Zhigang
title Determination of Organic Solvent in Radioactive Tracer [18F]PBR06 Injection by Cold-on-Column Inlet Gas Chromatography
title_short Determination of Organic Solvent in Radioactive Tracer [18F]PBR06 Injection by Cold-on-Column Inlet Gas Chromatography
title_full Determination of Organic Solvent in Radioactive Tracer [18F]PBR06 Injection by Cold-on-Column Inlet Gas Chromatography
title_fullStr Determination of Organic Solvent in Radioactive Tracer [18F]PBR06 Injection by Cold-on-Column Inlet Gas Chromatography
title_full_unstemmed Determination of Organic Solvent in Radioactive Tracer [18F]PBR06 Injection by Cold-on-Column Inlet Gas Chromatography
title_sort determination of organic solvent in radioactive tracer [18f]pbr06 injection by cold-on-column inlet gas chromatography
publisher Editorial Board of Journal of Isotopes
series Journal of Isotopes
issn 1000-7512
1000-7512
publishDate 2021-06-01
description To develop a quality control inspection method for determining content of ethanol and residual solvent in radiolabeled tracer [18F]PBR06 injection which is used for positron emission tomography imaging. Stabilwax CG column (30 m×0.52 mm, 1 μm) is selected. Temperature program: set initial temperature at 55 ℃, kept for 4 min, then increased to 200 ℃ at rate of 40 ℃/min, hold for 3 min. Hydrogen flame ionization detector is used and the temperature is 240 ℃. The carrier gas is high-purity nitrogen, and the inlet pressure is 5.5 psi (37.9 kPa). The temperature of Cold-on-Column inlet follows the column temperature. The results show that ethanol, acetonitrile, and DMSO have good linear relationships in the concentration range of 0.5%-12.0% (v·v-1), 0.004 0%-0.048 0% (g·g-1) and 0.025%-0.590% (g·g-1). The limit of quantification (S/N=10) for ethanol, acetonitrile, and DMSO is 0.15% (v·v-1), 0.002 9% (g·g-1) and 0.008 2% (g·g-1). The limits of detection (S/N=3) is 0.05% (v·v-1), 0.000 87% (g·g-1) and 0.002 5% (g·g-1), respectively. The results of the standard addition recovery show that the method has good accuracy. The Cold-on-Column inlet GC method developed in this study is suitable for inspecting the content of ethanol, acetonitrile and DMSO in [18F]PBR06 injection. The results of the method validation meet the requirements of the Chinese Pharmacopoeia 2020 edition. The method is accurate and time-saving, requiring only a small volume of sample, which is beneficial to improve the efficiency of product quality control inspection.
topic cold-on-column inlet
gas chromatography
pet imaging tracer
[18f]pbr06
residual solvent
url http://www.tws.org.cn/CN/10.7538/tws.2021.34.03.0288
work_keys_str_mv AT qiaohongwenshenglinghuiliangzhigang determinationoforganicsolventinradioactivetracer18fpbr06injectionbycoldoncolumninletgaschromatography
_version_ 1721211575112564736