BRIGHTNESS PERFORMANCE OF OFFICE INTERIOR DUE TO ROOM’S WINDOW COMPONENTS CONFIGURATION

The paper reports room’s brightness performance of glass dominance office building facade in Jakarta due to the use of tinted and reflective type of glass wall and the combination of these with internal roller and venetian shading types. Method used to collect the data was mainly by direct measureme...

Full description

Bibliographic Details
Main Authors: Asri Dinapradipta, Johanes Krisdianto
Format: Article
Language:English
Published: Petra Christian University 2017-12-01
Series:Dimensi: Journal of Architecture and Built Environment
Subjects:
Online Access:http://puslit2.petra.ac.id/ejournal/index.php/ars/article/view/20515
id doaj-cd79da8c9b0941e7879c1ca3729e8d4a
record_format Article
spelling doaj-cd79da8c9b0941e7879c1ca3729e8d4a2020-11-24T20:59:11ZengPetra Christian UniversityDimensi: Journal of Architecture and Built Environment0126-219X2338-78582017-12-01442129136BRIGHTNESS PERFORMANCE OF OFFICE INTERIOR DUE TO ROOM’S WINDOW COMPONENTS CONFIGURATIONAsri Dinapradipta0Johanes Krisdianto1 The paper reports room’s brightness performance of glass dominance office building facade in Jakarta due to the use of tinted and reflective type of glass wall and the combination of these with internal roller and venetian shading types. Method used to collect the data was mainly by direct measurements at three open-plan office buildings with different window components configurations under overcast sky condition, and at parallel sitting positions. Comparing the results of measurement with the standard of luminance value for office building was used as data analysis. Results show that the window components configuration influenced the luminance values of the interior and thus affected mostly on the brightness perception of the rooms. Both tinted and reflective glazing configured with roller blinds yielded accepted luminance value of rooms’ surfaces. They contributed to bright enough light perception of the rooms. On the other hand, the problem of room’s luminance values may occur with the use of reflective type of glass configured with the venetian blinds. The blinds exacerbated the daylight coming from window in which it resulted in significantly high average luminance value of the window.http://puslit2.petra.ac.id/ejournal/index.php/ars/article/view/20515Brightness; glass-facade office building; hot humid tropics; luminance values; window components configuretion.
collection DOAJ
language English
format Article
sources DOAJ
author Asri Dinapradipta
Johanes Krisdianto
spellingShingle Asri Dinapradipta
Johanes Krisdianto
BRIGHTNESS PERFORMANCE OF OFFICE INTERIOR DUE TO ROOM’S WINDOW COMPONENTS CONFIGURATION
Dimensi: Journal of Architecture and Built Environment
Brightness; glass-facade office building; hot humid tropics; luminance values; window components configuretion.
author_facet Asri Dinapradipta
Johanes Krisdianto
author_sort Asri Dinapradipta
title BRIGHTNESS PERFORMANCE OF OFFICE INTERIOR DUE TO ROOM’S WINDOW COMPONENTS CONFIGURATION
title_short BRIGHTNESS PERFORMANCE OF OFFICE INTERIOR DUE TO ROOM’S WINDOW COMPONENTS CONFIGURATION
title_full BRIGHTNESS PERFORMANCE OF OFFICE INTERIOR DUE TO ROOM’S WINDOW COMPONENTS CONFIGURATION
title_fullStr BRIGHTNESS PERFORMANCE OF OFFICE INTERIOR DUE TO ROOM’S WINDOW COMPONENTS CONFIGURATION
title_full_unstemmed BRIGHTNESS PERFORMANCE OF OFFICE INTERIOR DUE TO ROOM’S WINDOW COMPONENTS CONFIGURATION
title_sort brightness performance of office interior due to room’s window components configuration
publisher Petra Christian University
series Dimensi: Journal of Architecture and Built Environment
issn 0126-219X
2338-7858
publishDate 2017-12-01
description The paper reports room’s brightness performance of glass dominance office building facade in Jakarta due to the use of tinted and reflective type of glass wall and the combination of these with internal roller and venetian shading types. Method used to collect the data was mainly by direct measurements at three open-plan office buildings with different window components configurations under overcast sky condition, and at parallel sitting positions. Comparing the results of measurement with the standard of luminance value for office building was used as data analysis. Results show that the window components configuration influenced the luminance values of the interior and thus affected mostly on the brightness perception of the rooms. Both tinted and reflective glazing configured with roller blinds yielded accepted luminance value of rooms’ surfaces. They contributed to bright enough light perception of the rooms. On the other hand, the problem of room’s luminance values may occur with the use of reflective type of glass configured with the venetian blinds. The blinds exacerbated the daylight coming from window in which it resulted in significantly high average luminance value of the window.
topic Brightness; glass-facade office building; hot humid tropics; luminance values; window components configuretion.
url http://puslit2.petra.ac.id/ejournal/index.php/ars/article/view/20515
work_keys_str_mv AT asridinapradipta brightnessperformanceofofficeinteriorduetoroomswindowcomponentsconfiguration
AT johaneskrisdianto brightnessperformanceofofficeinteriorduetoroomswindowcomponentsconfiguration
_version_ 1716783528034697216