Uniaxial tensile and shear deformation tests of gold–tin eutectic solder film
This paper describes a novel experimental technique for measuring mechanical properties of gold-tin (Au–Sn) eutectic solder film used for soldering package in microelectromechanical systems (MEMS). Dual-source DC magnetron sputtering was employed to deposit Au-20 weight % (wt%) Sn film. The tensile...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
Taylor & Francis Group
2007-01-01
|
Series: | Science and Technology of Advanced Materials |
Online Access: | http://www.iop.org/EJ/abstract/1468-6996/8/3/A04 |
id |
doaj-cc4e5a94431042ecbe850bd0e455bdc6 |
---|---|
record_format |
Article |
spelling |
doaj-cc4e5a94431042ecbe850bd0e455bdc62020-11-24T22:20:31ZengTaylor & Francis GroupScience and Technology of Advanced Materials1468-69961878-55142007-01-0183146Uniaxial tensile and shear deformation tests of gold–tin eutectic solder filmTakahiro Namazu, Hideki Takemoto, Hiroshi Fujita and Shozo InoueThis paper describes a novel experimental technique for measuring mechanical properties of gold-tin (Au–Sn) eutectic solder film used for soldering package in microelectromechanical systems (MEMS). Dual-source DC magnetron sputtering was employed to deposit Au-20 weight % (wt%) Sn film. The tensile test with in situ X-ray diffraction (XRD) measurement evaluates the Young's modulus and Poisson's ratio at intermediate temperatures. The Young's modulus and Poisson's ratio at room temperature were found to be 51.3 GPa and 0.288, lower than bulk values. The Young's modulus decreased with increasing temperature, whereas the Poisson's ratio did not depend on temperature. The XRD tensile test also showed creep deformation behavior of Au–Sn film. We have developed a shear deformation test technique, which is performed by using Au–Sn film sandwiched by two single crystal silicon (Si) cantilever structures, to characterize the shear properties of the film. The shear moduli obtained from the shear deformation tests ranged from 11.5 to 13.3 GPa, about 38% lower than those from the XRD tensile tests. The measured shear strength from 12 to 17 MPa exhibited a temperature dependency. Information about the tensile and shear characteristics would likely to be of great use in designing Au–Sn soldering packages for MEMS.http://www.iop.org/EJ/abstract/1468-6996/8/3/A04 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Takahiro Namazu, Hideki Takemoto, Hiroshi Fujita and Shozo Inoue |
spellingShingle |
Takahiro Namazu, Hideki Takemoto, Hiroshi Fujita and Shozo Inoue Uniaxial tensile and shear deformation tests of gold–tin eutectic solder film Science and Technology of Advanced Materials |
author_facet |
Takahiro Namazu, Hideki Takemoto, Hiroshi Fujita and Shozo Inoue |
author_sort |
Takahiro Namazu, Hideki Takemoto, Hiroshi Fujita and Shozo Inoue |
title |
Uniaxial tensile and shear deformation tests of gold–tin eutectic solder film |
title_short |
Uniaxial tensile and shear deformation tests of gold–tin eutectic solder film |
title_full |
Uniaxial tensile and shear deformation tests of gold–tin eutectic solder film |
title_fullStr |
Uniaxial tensile and shear deformation tests of gold–tin eutectic solder film |
title_full_unstemmed |
Uniaxial tensile and shear deformation tests of gold–tin eutectic solder film |
title_sort |
uniaxial tensile and shear deformation tests of gold–tin eutectic solder film |
publisher |
Taylor & Francis Group |
series |
Science and Technology of Advanced Materials |
issn |
1468-6996 1878-5514 |
publishDate |
2007-01-01 |
description |
This paper describes a novel experimental technique for measuring mechanical properties of gold-tin (Au–Sn) eutectic solder film used for soldering package in microelectromechanical systems (MEMS). Dual-source DC magnetron sputtering was employed to deposit Au-20 weight % (wt%) Sn film. The tensile test with in situ X-ray diffraction (XRD) measurement evaluates the Young's modulus and Poisson's ratio at intermediate temperatures. The Young's modulus and Poisson's ratio at room temperature were found to be 51.3 GPa and 0.288, lower than bulk values. The Young's modulus decreased with increasing temperature, whereas the Poisson's ratio did not depend on temperature. The XRD tensile test also showed creep deformation behavior of Au–Sn film. We have developed a shear deformation test technique, which is performed by using Au–Sn film sandwiched by two single crystal silicon (Si) cantilever structures, to characterize the shear properties of the film. The shear moduli obtained from the shear deformation tests ranged from 11.5 to 13.3 GPa, about 38% lower than those from the XRD tensile tests. The measured shear strength from 12 to 17 MPa exhibited a temperature dependency. Information about the tensile and shear characteristics would likely to be of great use in designing Au–Sn soldering packages for MEMS. |