Power and Current Limiting Control of Wind Turbines Based on PMSG Under Unbalanced Grid Voltage

Unbalanced grid voltage sags are the severe challenge for wind power generation system which connected to the grid successfully. The dc bus voltage and output power will fluctuate under unbalanced grid voltage. Moreover, the voltage sags will lead to the increase of peak current, which will bring po...

Full description

Bibliographic Details
Main Authors: Jun Liu, Chencong Zhao, Zhouhua Xie
Format: Article
Language:English
Published: IEEE 2021-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/9316689/
id doaj-cbae61cb0d3d4ec398b2e77bc406b1c9
record_format Article
spelling doaj-cbae61cb0d3d4ec398b2e77bc406b1c92021-03-30T15:22:36ZengIEEEIEEE Access2169-35362021-01-0199873988310.1109/ACCESS.2021.30498399316689Power and Current Limiting Control of Wind Turbines Based on PMSG Under Unbalanced Grid VoltageJun Liu0Chencong Zhao1https://orcid.org/0000-0001-5796-8811Zhouhua Xie2https://orcid.org/0000-0001-6696-0766College of Automation, Xi’an University of Technology, Xi’an, ChinaCollege of Automation, Xi’an University of Technology, Xi’an, ChinaXi’an Thermal Power Research Institute Company Ltd., Xi’an, ChinaUnbalanced grid voltage sags are the severe challenge for wind power generation system which connected to the grid successfully. The dc bus voltage and output power will fluctuate under unbalanced grid voltage. Moreover, the voltage sags will lead to the increase of peak current, which will bring potential safety hazards to the operation of wind power system. This paper proposes a simple current limiting control scheme without auxiliary equipment, which based on the detailed analysis of the excessive peak current. In this scheme, the machine side converter (MSC) controller adjusts the electromagnetic power according to the power transmitted to the grid by the grid side converter (GSC). Meanwhile, it converts the unbalanced power on the dc-link into the rotor kinetic energy, avoiding the dc-link overvoltage. The GSC controller can not only ensure that the three-phase inverter currents are in the maximum safe range that the converters can bear, but also provide reactive power support for the grid. Furthermore, the fluctuations on dc bus voltage and output power can be eliminated effectively by using the GSC controller. The feasibility of the proposed scheme and the superiority over the traditional control schemes have been verified by simulations under different types of unbalanced voltage.https://ieeexplore.ieee.org/document/9316689/Unbalanced grid voltagepeak currentcurrent limiting controlrotor kinetic energyreactive power support
collection DOAJ
language English
format Article
sources DOAJ
author Jun Liu
Chencong Zhao
Zhouhua Xie
spellingShingle Jun Liu
Chencong Zhao
Zhouhua Xie
Power and Current Limiting Control of Wind Turbines Based on PMSG Under Unbalanced Grid Voltage
IEEE Access
Unbalanced grid voltage
peak current
current limiting control
rotor kinetic energy
reactive power support
author_facet Jun Liu
Chencong Zhao
Zhouhua Xie
author_sort Jun Liu
title Power and Current Limiting Control of Wind Turbines Based on PMSG Under Unbalanced Grid Voltage
title_short Power and Current Limiting Control of Wind Turbines Based on PMSG Under Unbalanced Grid Voltage
title_full Power and Current Limiting Control of Wind Turbines Based on PMSG Under Unbalanced Grid Voltage
title_fullStr Power and Current Limiting Control of Wind Turbines Based on PMSG Under Unbalanced Grid Voltage
title_full_unstemmed Power and Current Limiting Control of Wind Turbines Based on PMSG Under Unbalanced Grid Voltage
title_sort power and current limiting control of wind turbines based on pmsg under unbalanced grid voltage
publisher IEEE
series IEEE Access
issn 2169-3536
publishDate 2021-01-01
description Unbalanced grid voltage sags are the severe challenge for wind power generation system which connected to the grid successfully. The dc bus voltage and output power will fluctuate under unbalanced grid voltage. Moreover, the voltage sags will lead to the increase of peak current, which will bring potential safety hazards to the operation of wind power system. This paper proposes a simple current limiting control scheme without auxiliary equipment, which based on the detailed analysis of the excessive peak current. In this scheme, the machine side converter (MSC) controller adjusts the electromagnetic power according to the power transmitted to the grid by the grid side converter (GSC). Meanwhile, it converts the unbalanced power on the dc-link into the rotor kinetic energy, avoiding the dc-link overvoltage. The GSC controller can not only ensure that the three-phase inverter currents are in the maximum safe range that the converters can bear, but also provide reactive power support for the grid. Furthermore, the fluctuations on dc bus voltage and output power can be eliminated effectively by using the GSC controller. The feasibility of the proposed scheme and the superiority over the traditional control schemes have been verified by simulations under different types of unbalanced voltage.
topic Unbalanced grid voltage
peak current
current limiting control
rotor kinetic energy
reactive power support
url https://ieeexplore.ieee.org/document/9316689/
work_keys_str_mv AT junliu powerandcurrentlimitingcontrolofwindturbinesbasedonpmsgunderunbalancedgridvoltage
AT chencongzhao powerandcurrentlimitingcontrolofwindturbinesbasedonpmsgunderunbalancedgridvoltage
AT zhouhuaxie powerandcurrentlimitingcontrolofwindturbinesbasedonpmsgunderunbalancedgridvoltage
_version_ 1724179577144606720